41 research outputs found

    Longitudinal stability of asthma characteristics and biomarkers from the Airways Disease Endotyping for Personalized Therapeutics (ADEPT) study

    Get PDF
    BACKGROUND: Asthma is a biologically heterogeneous disease and development of novel therapeutics requires understanding of pathophysiologic phenotypes. There is uncertainty regarding the stability of clinical characteristics and biomarkers in asthma over time. This report presents the longitudinal stability over 12 months of clinical characteristics and clinically accessible biomarkers from ADEPT. METHODS: Mild, moderate, and severe asthma subjects were assessed at 5 visits over 12 months. Assessments included patient questionnaires, spirometry, bronchodilator reversibility, fractional exhaled nitric oxide (FENO), and biomarkers measured in induced sputum. RESULTS: Mild (n = 52), moderate (n = 55), and severe (n = 51) asthma cohorts were enrolled from North America and Western Europe. For all clinical characteristics and biomarkers, group mean data showed no significant change from visit to visit. However, individual data showed considerable variability. FEV1/FVC ratio showed excellent reproducibility while pre-bronchodilator FEV1 and FVC were only moderately reproducible. Of note bronchodilator FEV1 reversibility showed low reproducibility, with the nonreversible phenotype much more reproducible than the reversible phenotype. The 7-item asthma control questionnaire (ACQ7) demonstrated moderate reproducibility for the combined asthma cohorts, but the uncontrolled asthma phenotype (ACQ7 > 1.5) was inconstant in mild and moderate asthma but stable in severe asthma. FENO demonstrated good reproducibility, with the FENO-low phenotype (FENO < 35 ppb) more stable than the FENO-high phenotype (FENO ≥ 35 ppb). Induced sputum inflammatory phenotypes showed marked variability across the 3 sputum samples taken over 6 months. CONCLUSIONS: The ADEPT cohort showed group stability, individual stability in some parameters e.g. low FEV1/FVC ratio, and low FENO, but marked individual variability in other clinical characteristics and biomarkers e.g. type-2 biomarkers over 12 months. This variability is possibly related to seasonal variations in climate and allergen exposure, medication changes and acute exacerbations. The implications for patient selection strategies based on clinical biomarkers may be considerable

    Inhibitor of apoptosis proteins, NAIP, cIAP1 and cIAP2 expression during macrophage differentiation and M1/M2 polarization

    Get PDF
    Monocytes and macrophages constitute the first line of defense of the immune system against external pathogens. Macrophages have a highly plastic phenotype depending on environmental conditions; the extremes of this phenotypic spectrum are a pro-inflammatory defensive role (M1 phenotype) and an anti-inflammatory tissue-repair one (M2 phenotype). The Inhibitor of Apoptosis (IAP) proteins have important roles in the regulation of several cellular processes, including innate and adaptive immunity. In this study we have analyzed the differential expression of the IAPs, NAIP, cIAP1 and cIAP2, during macrophage differentiation and polarization into M1 or M2. In polarized THP-1 cells and primary human macrophages, NAIP is abundantly expressed in M2 macrophages, while cIAP1 and cIAP2 show an inverse pattern of expression in polarized macrophages, with elevated expression levels of cIAP1 in M2 and cIAP2 preferentially expressed in M1. Interestingly, treatment with the IAP antagonist SMC-LCL161, induced the upregulation of NAIP in M2, the downregulation of cIAP1 in M1 and M2 and an induction of cIAP2 in M1 macrophages.This work was supported by Universidad de Granada, Plan Propio 2015;#P3B: FAM, VMC (http://investigacion.ugr.es/pages/planpropio/2015/ resoluciones/p3b_def_28072015); Universidad de Granada CEI BioTic;#CAEP2-84: VMC (http:// biotic.ugr.es/pages/resolucionprovisional enseaanzapractica22demayo/!); and Canadian nstitutes of Health Research;#231421, #318176, #361847: STB, ECL, RK (http://www.cihr-irsc.gc. ca/e/193.html). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript

    Performance Characteristics of Breezhaler((R)) and Aerolizer((R)) in the Real-World Setting

    Get PDF
    The evaluation of errors in use with different inhaler devices is challenging to quantify as there are a number of definitions of critical and non-critical errors with respect to inhaler use; in addition, performance characteristics of the device, such as airflow resistance, can also influence effective use in the real-world setting. Repeated observations and checking/correcting inhaler use are essential to optimise clinical effectiveness of inhaled therapy in patients. Breezhaler® is a single unit-dose dry powder inhaler used in chronic obstructive pulmonary disease and in asthma (budesonide) that has low airflow resistance, making it easier for patients of varying disease severities to achieve the inhalation flow rate required for lung deposition of treatment. Similar to Breezhaler®, the Aerolizer® is a single unit-dose dry powder inhaler used in asthma management with low airflow resistance. Studies have shown relatively low rates of critical errors with Breezhaler® and Aerolizer®, with similarities in the critical errors reported; these data on critical errors together with similarities in the usability of Breezhaler® and Aerolizer® further support the functional similarity between the two devices in both asthma and chronic obstructive pulmonary disease. Breezhaler® also has patient-feedback features, including use of a transparent drug capsule that can be checked after inhalation to see it is empty. The low resistance of the dose-confirming Breezhaler® results in less inspiratory effort being required by patients for its effective use, which allows the device to be used effectively across a wide age range of patients and disease severities

    Severe Asthma Standard-of-Care Background Medication Reduction With Benralizumab: ANDHI in Practice Substudy

    Full text link
    peer reviewedBackground: The phase IIIb, randomized, parallel-group, placebo-controlled ANDHI double-blind (DB) study extended understanding of the efficacy of benralizumab for patients with severe eosinophilic asthma. Patients from ANDHI DB could join the 56-week ANDHI in Practice (IP) single-arm, open-label extension substudy. Objective: Assess potential for standard-of-care background medication reductions while maintaining asthma control with benralizumab. Methods: Following ANDHI DB completion, eligible adults were enrolled in ANDHI IP. After an 8-week run-in with benralizumab, there were 5 visits to potentially reduce background asthma medications for patients achieving and maintaining protocol-defined asthma control with benralizumab. Main outcome measures for non–oral corticosteroid (OCS)-dependent patients were the proportions with at least 1 background medication reduction (ie, lower inhaled corticosteroid dose, background medication discontinuation) and the number of adapted Global Initiative for Asthma (GINA) step reductions at end of treatment (EOT). Main outcomes for OCS-dependent patients were reductions in daily OCS dosage and proportion achieving OCS dosage of 5 mg or lower at EOT. Results: For non–OCS-dependent patients, 53.3% (n = 208 of 390) achieved at least 1 background medication reduction, increasing to 72.6% (n = 130 of 179) for patients who maintained protocol-defined asthma control at EOT. A total of 41.9% (n = 163 of 389) achieved at least 1 adapted GINA step reduction, increasing to 61.8% (n = 110 of 178) for patients with protocol-defined EOT asthma control. At ANDHI IP baseline, OCS dosages were 5 mg or lower for 40.4% (n = 40 of 99) of OCS-dependent patients. Of OCS-dependent patients, 50.5% (n = 50 of 99) eliminated OCS and 74.7% (n = 74 of 99) achieved dosages of 5 mg or lower at EOT. Conclusions: These findings demonstrate benralizumab's ability to improve asthma control, thereby allowing background medication reduction. © 202

    Therapie

    No full text
    Pharmacoepidemiology studies are of particular interest in the respiratory field and especially for inhaled drugs. In real-life, excessive use of rescue medications and under- or inappropriate-prescribing of preventer medications has been shown. In asthma and chronic obstructive pulmonary disease (COPD), the poor use of inhalation device is associated with uncontrolled diseases and occurrence of exacerbations. Inhalation treatments are directly delivered within the lung and are generally considered as safe. However, systemic adverse drug reactions that were not evidenced in clinical trials may be observed after a long-term treatment

    Familial site-specific ovarian cancer is linked to BRCA1 on 17q12-21.

    No full text
    In a study of nine families with "site-specific" ovarian cancer (criterion: three or more cases of epithelial ovarian cancer and no cases of breast cancer diagnosed at age < 50 years) we have obtained evidence of linkage to the breast-ovarian cancer susceptibility gene, BRCA1 on 17q12-21. If the risk of cancer in these families is assumed to be restricted to the ovary, the best estimate of the proportion of families linked to BRCA1 is .78 (95% confidence interval .32-1.0). If predisposition to both breast and ovarian cancer is assumed, the proportion linked is 1.0 (95% confidence interval .46-1.0). The linkage of familial site-specific ovarian cancer to BRCA1 indicates the possibility of predictive testing in such families; however, this is only appropriate in families where the evidence for linkage to BRCA1 is conclusive
    corecore