2,075 research outputs found

    Effect of high temperature heat treatments on the quality factor of a large-grain superconducting radio-frequency niobium cavity

    Get PDF
    Large-grain Nb has become a viable alternative to fine-grain Nb for the fabrication of superconducting radio-frequency cavities. In this contribution we report the results from a heat treatment study of a large-grain 1.5 GHz single-cell cavity made of "medium purity" Nb. The baseline surface preparation prior to heat treatment consisted of standard buffered chemical polishing. The heat treatment in the range 800 - 1400 C was done in a newly designed vacuum induction furnace. Q0 values of the order of 2x1010 at 2.0 K and peak surface magnetic field (Bp) of 90 mT were achieved reproducibly. A Q0-value of (5+-1)1010 at 2.0 K and Bp = 90 mT was obtained after heat treatment at 1400 C. This is the highest value ever reported at this temperature, frequency and field. Samples heat treated with the cavity at 1400 C were analyzed by secondary ion mass spectrometry, secondary electron microscopy, energy dispersive X-ray, point contact tunneling and X-ray diffraction and revealed a complex surface composition which includes titanium oxide, increased carbon and nitrogen content but reduced hydrogen concentration compared to a non heat-treated sample

    Paced left ventricular QRS width and ECG parameters predict outcomes after cardiac resynchronization therapy: PROSPECT-ECG substudy.

    No full text
    International audienceBACKGROUND: For patients with symptomatic New York Heart Association class III or IV, ejection fraction ≤ 35%, and QRS ≥ 130 ms, cardiac resynchronization therapy (CRT) has become an established treatment option. However, use of these implant criteria fails to result in clinical or echocardiographic improvement in 30% to 45% of CRT patients. METHODS AND RESULTS: The Predictors of Response to CRT (PROSPECT)-ECG is a substudy of the prospective observational PROSPECT trial. ECGs collected before, during, and after CRT implantation were analyzed. Primary outcomes were improvement in clinical composite score (CCS) and reduction of left ventricular end systolic volume (LVESV) of >15% after 6 months. Age, sex, cause of cardiomyopathy, myocardial infarction location, right ventricular function, mitral regurgitation, preimplantation QRS width, preimplantation PR interval, preimplantation right ventricular-paced QRS width, preimplantation axis categories, LV-paced QRS width, postimplantation axis categories, difference between biventricular (Bi-V) pacing and preimplantation QRS width, and QRS bundle branch morphological features were analyzed univariably in logistic regression models to predict outcomes. All significant predictors (α=0.1), age, and sex were used for multivariable analyses. Cardiomyopathy cause interaction and subanalyses were also performed. In multivariable analyses, only QRS left bundle branch morphological features predicted both CCS (odds ratio [OR]=2.46, P=0.02) and LVESV (OR=2.89, P=0.048) response. The difference between Bi-V and preimplantation QRS width predicted CCS improvement (OR=0.89, P=0.04). LV-paced QRS width predicted LVESV reduction (OR=0.86, P=0.01). Specifically, an LV-paced QRS width of ≤ 200 ms was predictive of nonischemic LVESV reduction (OR=5.12, P=0.01). CONCLUSIONS: Baseline left bundle branch QRS morphological features, LV-paced QRS width, and the difference between Bi-V and preimplantation QRS width can predict positive outcomes after CRT and may represent a novel intraprocedural method to optimize coronary sinus lead placement. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00253357

    Observation of Squeezed Light in the 2  Μm Region

    Get PDF
    We present the generation and detection of squeezed light in the 2  μm wavelength region. This experiment is a crucial step in realizing the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilized 1984 nm thulium fiber laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured 4.0±0.1  dB of squeezing and 10.5±0.5  dB of antisqueezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB

    Bias-voltage dependence of the magneto-resistance in ballistic vacuum tunneling: Theory and application to planar Co(0001) junctions

    Full text link
    Motivated by first-principles results for jellium and by surface-barrier shapes that are typically used in electron spectroscopies, the bias voltage in ballistic vacuum tunneling is treated in a heuristic manner. The presented approach leads in particular to a parameterization of the tunnel-barrier shape, while retaining a first-principles description of the electrodes. The proposed tunnel barriers are applied to Co(0001) planar tunnel junctions. Besides discussing main aspects of the present scheme, we focus in particular on the absence of the zero-bias anomaly in vacuum tunneling.Comment: 19 pages with 8 figure

    Examining the Impact of Imputation Errors on Fine-Mapping Using DNA Methylation QTL as a Model Trait

    Get PDF
    Genetic variants disrupting DNA methylation at CpG dinucleotides (CpG-SNP) provide a set of known causal variants to serve as models for testing fine-mapping methodology. We use 1716 CpG-SNPs to test three fine-mapping approaches (BIMBAM, BSLMM, and the J-test), assessing the impact of imputation errors and the choice of reference panel by using both whole-genome sequence (WGS), and genotype array data on the same individuals (n=1166). The choice of imputation reference panel had a strong effect on imputation accuracy, with the 1000 Genomes Phase 3 (1000G) reference panel (n=2504 from 26 populations) giving a mean non-reference discordance rate between imputed and sequenced genotypes of 3.2% compared to 1.6% when using the Haplotype Reference Consortium (HRC) reference panel (n=32470 Europeans). These imputation errors impacted on whether the CpG-SNP was included in the 95% credible set, with a difference of ∼ 23% and ∼ 7% between the WGS and the 1000G and HRC imputed datasets respectively. All of the fine-mapping methods failed to reach the expected 95% coverage of the CpG-SNP. This is attributed to secondary cis genetic effects that are unable to be statistically separated from the CpG-SNP, and through a masking mechanism where the effect of the methylation disrupting allele at the CpG-SNP is hidden by the effect of a nearby SNP that has strong LD with the CpG-SNP. The reduced accuracy in fine-mapping a known causal variant in a low level biological trait with imputed genetic data has implications for the study of higher order complex traits and disease

    Classification of hyperbolic Dynkin diagrams, root lengths and Weyl group orbits

    Full text link
    We give a criterion for a Dynkin diagram, equivalently a generalized Cartan matrix, to be symmetrizable. This criterion is easily checked on the Dynkin diagram. We obtain a simple proof that the maximal rank of a Dynkin diagram of compact hyperbolic type is 5, while the maximal rank of a symmetrizable Dynkin diagram of compact hyperbolic type is 4. Building on earlier classification results of Kac, Kobayashi-Morita, Li and Sa\c{c}lio\~{g}lu, we present the 238 hyperbolic Dynkin diagrams in ranks 3-10, 142 of which are symmetrizable. For each symmetrizable hyperbolic generalized Cartan matrix, we give a symmetrization and hence the distinct lengths of real roots in the corresponding root system. For each such hyperbolic root system we determine the disjoint orbits of the action of the Weyl group on real roots. It follows that the maximal number of disjoint Weyl group orbits on real roots in a hyperbolic root system is 4.Comment: J. Phys. A: Math. Theor (to appear

    Relativistic separable dual-space Gaussian Pseudopotentials from H to Rn

    Full text link
    We generalize the concept of separable dual-space Gaussian pseudopotentials to the relativistic case. This allows us to construct this type of pseudopotential for the whole periodic table and we present a complete table of pseudopotential parameters for all the elements from H to Rn. The relativistic version of this pseudopotential retains all the advantages of its nonrelativistic version. It is separable by construction, it is optimal for integration on a real space grid, it is highly accurate and due to its analytic form it can be specified by a very small number of parameters. The accuracy of the pseudopotential is illustrated by an extensive series of molecular calculations

    Trends in, and predictors of, anxiety and specific worries following colposcopy: a 12-month longitudinal study

    Get PDF
    Objective Little is known about which women are at greatest risk of adverse psychological after-effects following colposcopy. This study examined time trends in, and identified predictors of, anxiety and specific worries over 12 months. Methods Women attending two hospital-based colposcopy clinics for abnormal cervical cytology were invited to complete psychosocial questionnaires at 4, 8 and 12 months following colposcopy. General anxiety and screening-specific worries (about cervical cancer, having sex and future fertility) were measured. Generalised estimating equations were used to assess associations between socio-demographic, lifestyle and clinical variables and risk of psychological outcomes. Results Of 584 women initially recruited, 429, 343 and 303 completed questionnaires at 4, 8 and 12 months, respectively. Screening-specific worries declined significantly over time but were still relatively high at 12 months: 23%, 39% and 18% for worries about cervical cancer, fertility and having sex, respectively. Anxiety remained stable (20%) over time. Risks of cervical cancer worry and anxiety were both almost double in women without private health insurance (cervical cancer worry: OR = 1.80, 95% CI 1.25–2.61; anxiety: OR = 1.84, 95% CI 1.20–2.84). Younger women (<40 years) had higher risk of fertility worries. Non-Irish women had higher risk of anxiety (OR = 2.13, 95% CI 1.13–4.01). Conclusions Screening-specific worries declined over time but anxiety remained stable. Notable proportions of women still reported adverse outcomes 12 months following colposcopy, with predictors varying between outcomes. Women in socio-demographically vulnerable groups were at greatest risk of adverse psychological outcomes. This information could inform development of interventions to alleviate psychological distress post-colposcopy. Copyright © 2015 John Wiley & Sons, Ltd
    • …
    corecore