8 research outputs found

    Inter-rater reliability of clinical mobility measures in ankylosing spondylitis.

    No full text
    Several measurements are often used in daily clinical practice in the assessment of Ankylosing Spondylitis (AS) patients. The Assessment in SpondyloArthiritis International Society (ASAS) recommend in its core set: chest expansion modified Schöber test, Occiput to wall distance, lateral lumbar flexion, cervical rotation and The Bath Ankylosing Spondylitis Metrology Index (BASMI). BASMI also includes five measurements, some of them recommended by ASAS. Three versions of BASMI have been published with different scales and intervals for each component of the index. Though studies about reliability of these measurements are needed. The aim of this study was to analyze inter-rater reliability of recommended spinal mobility measures in AS. We examined reproducibility of spinal mobility measurements on 33 AS patients performed by two experienced rheumatologists in the same day. Descriptive statistics, Intraclass Correlation Coefficients (ICC), and Smallest Detectable Difference (SDD) using the Bland-Altman criteria were obtained for all the measurements. Chest expansion showed the lowest value of ICC (0.66) and occiput-wall the highest (0.97). SDD was 2.43 units for BASMI2 and 1.27 units for BASMI10. Reliability according to ICC was moderate to high in all measurements. BASMI10, instead BASMI2, must be used: measurements used to calculate are the same but there is better reliability. Inter-rater variation, expressed as SDD, must be taken in account: smaller improvements do not demonstrate the efficacy of treatment because they can be due to experimental error and not to the treatment itself

    'Atherothrombosis-associated microRNAs in Antiphospholipid syndrome and Systemic Lupus Erythematosus patients'.

    No full text
    MicroRNAs markedly affect the immune system, and have a relevant role in CVD and autoimmune diseases. Yet, no study has analyzed their involvement in atherothrombosis related to APS and SLE patients. This study intended to: 1) identify and characterize microRNAs linked to CVD in APS and SLE; 2) assess the effects of specific autoantibodies. Six microRNAs, involved in atherothrombosis development, were quantified in purified leukocytes from 23 APS and 64 SLE patients, and 56 healthy donors. Levels of microRNAs in neutrophils were lower in APS and SLE than in healthy donors. Gene and protein expression of miRNA biogenesis-related molecules were also reduced. Accordingly, more than 75% of identified miRNAs by miRNA profiling were underexpressed. In monocytes, miR124a and -125a were low, while miR-146a and miR-155 appeared elevated. Altered microRNAs' expression was linked to autoimmunity, thrombosis, early atherosclerosis, and oxidative stress in both pathologies. In vitro treatment of neutrophils, monocytes, and ECs with aPL-IgG or anti-dsDNA-IgG antibodies deregulated microRNAs expression, and decreased miRNA biogenesis-related proteins. Monocyte transfections with pre-miR-124a and/or -125a caused reduction in atherothrombosis-related target molecules. In conclusion, microRNA biogenesis, significantly altered in neutrophils of APS and SLE patients, is associated to their atherothrombotic status, further modulated by specific autoantibodies

    Novel Approach to Estimate Osteoarthritis Progression: Use of the Reliable Change Index in the Evaluation of Joint Space Loss

    No full text
    International audienceObjective Osteoarthritis-related changes in joint space measurements over time are small and sensitive to measurement error. The Reliable Change Index (RCI) determines whether the magnitude of change observed in an individual can be attributed to true change. This study aimed to examine the RCI as a novel approach to estimating osteoarthritis progression. Methods Data were from 167 men and 392 women with knee osteoarthritis (diagnosed using the American College of Rheumatology criteria) randomized to the placebo arm of the 3-year Strontium Ranelate Efficacy in Knee Osteoarthritis trial (SEKOIA) and assessed annually. The RCI was used to determine whether the magnitude of change in joint space width (JSW) on radiographs between study years was likely to be true or due to measurement error. Results Between consecutive years, 57-69% of participants had an apparent decrease (change <0) in JSW, while 31-43% of participants had annual changes indicating improvement in JSW. The RCI identified JSW decreases in only 6.0% of patients between baseline and year 1, and in 4.5% of patients between the remaining study years. The apparent increases in JSW were almost eliminated between baseline and year 1, and between years 1 and 2 only 1.3% of patients had a significant increase, dropping to 0.9% between years 2 and 3. Conclusion The RCI provides a method to identify change in JSW, removing many apparent changes that are likely to be due to measurement error. This method appears to be useful for assessing change in JSW from radiographs in clinical and research settings

    High kellgren-lawrence grade and bone marrow lesions predict worsening rates of radiographic joint space narrowing the SEKOIA study

    No full text
    corecore