135 research outputs found

    Fluorescence-guided detection of pituitary neuroendocrine tumor (PitNET) tissue during endoscopic transsphenoidal surgery available agents, their potential, and technical aspects

    Get PDF
    Differentiation of pituitary neuroendocrine tumor (PitNET) tissue from surrounding normal tissue during surgery is challenging. A number of fluorescent agents is available for visualization of tissue discrepancy, with the potential of improving total tumor resection. This review evaluates the availability, clinical and technical applicability of the various fluorescent agents within the field of pituitary surgery. According to PRISMA guidelines, a systematic review was performed to identify reports describing results of in vivo application of fluorescent agents. In this review, 15 publications were included. Sodium Fluorescein (FNa) was considered in two studies. The first study reported noticeable fluorescence in adenoma tissue, the second demonstrated the strongest fluorescence in non-functioning pituitary adenomas. 5-Aminolevulinic acid (5-ALA) was investigated in three studies. One study compared laser-based optical biopsy system (OBS) with photo-diagnostic filter (PD) and found that the OBS was able to detect all microadenomas, even when MRI was negative. The second study retrospectively analyzed twelve pituitary adenomas and found only one positive for fluorescence. The third investigated fifteen pituitary adenomas of which one displayed vague fluorescence. Indocyanine green (ICG) was researched in four studies with variable results. Second-Window ICG yielded no significant difference between functioning and non-functioning adenomas in one study, while a second study displayed 4 times higher fluorescence in tumor tissue than in normal tissue. In three studies, OTL38 showed potential in non-functioning pituitary adenomas. At present, evidence for fluorescent agents to benefit total resection of PitNETs is lacking. OTL38 can potentially serve as a selective fluorescent agent in non-functioning pituitary adenomas in the near future

    Epidermal Growth Factor Receptor Plays an Anabolic Role in Bone Metabolism In Vivo

    Get PDF
    While the epidermal growth factor receptor (EGFR)–mediated signaling pathway has been shown to have vital roles in many developmental and pathologic processes, its functions in the development and homeostasis of the skeletal system has been poorly defined. To address its in vivo role, we constructed transgenic and pharmacologic mouse models and used peripheral quantitative computed tomography (pQCT), micro–computed tomography (µCT) and histomorphometry to analyze their trabecular and cortical bone phenotypes. We initially deleted the EGFR in preosteoblasts/osteoblasts using a Cre/loxP system (Col-Cre Egfrf/f), but no bone phenotype was observed because of incomplete deletion of the Egfr genomic locus. To further reduce the remaining osteoblastic EGFR activity, we introduced an EGFR dominant-negative allele, Wa5, and generated Col-Cre EgfrWa5/f mice. At 3 and 7 months of age, both male and female mice exhibited a remarkable decrease in tibial trabecular bone mass with abnormalities in trabecular number and thickness. Histologic analyses revealed decreases in osteoblast number and mineralization activity and an increase in osteoclast number. Significant increases in trabecular pattern factor and structural model index indicate that trabecular microarchitecture was altered. The femurs of these mice were shorter and smaller with reduced cortical area and periosteal perimeter. Moreover, colony-forming unit–fibroblast (CFU-F) assay indicates that these mice had fewer bone marrow mesenchymal stem cells and committed progenitors. Similarly, administration of an EGFR inhibitor into wild-type mice caused a significant reduction in trabecular bone volume. In contrast, EgfrDsk5/+ mice with a constitutively active EGFR allele displayed increases in trabecular and cortical bone content. Taken together, these data demonstrate that the EGFR signaling pathway is an important bone regulator and that it primarily plays an anabolic role in bone metabolism. © 2011 American Society for Bone and Mineral Research

    Primeras experiencias de diseño, fabricación y caracterización de diodos de paso para celdas solares de uso espacial

    Get PDF
    Se presentan los primeros desarrollos en la elaboración y caracterización eléctrica de diodos de paso de silicio para uso espacial. Se elaboraron diodos con dos tipos de juntura: n+p y n+pp++ Se detalla el proceso de fabricación de este dispositivo, que requiere el uso de técnicas similares a las empleadas en la elaboración de celdas fotovoltaicas: oxidación, difusión de dopantes, fotolitografía y deposición de contactos metálicos. Si bien ésta tecnología es bien conocida y se puede encontrar en los libros de texto, éstos dispositivos son los primeros que se fabrican íntegramente en el país. Se caracterizaron eléctricamente mediante la medición de la curva corriente-tensión (I-V) sin control de temperatura. Asimismo, para estudiar el funcionamiento del dispositivo, tanto desde el punto de vista eléctrico como electrónico, se presentan simulaciones teóricas con los programas PC1D5 y Simusol.This paper presents our early developments on the elaboration and electric characterization of silicon bypass diode for space uses. Two different types of junction diode were manufactured: n+p and n+pp+. The elaboration´s processes of those devices which requires similar techniques to those utilized in the manufacture of photovoltaic cells is detailed: oxidation, phosphorus diffusion, photolithography and metallic contact deposition. Current-Voltage curves with no temperature control were measured and theoretical simulations using PC1D5 and Simusol programs were presented.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES

    Primeras experiencias de diseño, fabricación y caracterización de diodos de paso para celdas solares de uso espacial

    Get PDF
    Se presentan los primeros desarrollos en la elaboración y caracterización eléctrica de diodos de paso de silicio para uso espacial. Se elaboraron diodos con dos tipos de juntura: n+p y n+pp++ Se detalla el proceso de fabricación de este dispositivo, que requiere el uso de técnicas similares a las empleadas en la elaboración de celdas fotovoltaicas: oxidación, difusión de dopantes, fotolitografía y deposición de contactos metálicos. Si bien ésta tecnología es bien conocida y se puede encontrar en los libros de texto, éstos dispositivos son los primeros que se fabrican íntegramente en el país. Se caracterizaron eléctricamente mediante la medición de la curva corriente-tensión (I-V) sin control de temperatura. Asimismo, para estudiar el funcionamiento del dispositivo, tanto desde el punto de vista eléctrico como electrónico, se presentan simulaciones teóricas con los programas PC1D5 y Simusol.This paper presents our early developments on the elaboration and electric characterization of silicon bypass diode for space uses. Two different types of junction diode were manufactured: n+p and n+pp+. The elaboration´s processes of those devices which requires similar techniques to those utilized in the manufacture of photovoltaic cells is detailed: oxidation, phosphorus diffusion, photolithography and metallic contact deposition. Current-Voltage curves with no temperature control were measured and theoretical simulations using PC1D5 and Simusol programs were presented.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES

    Comparison between a commercial class B pyranometer and a photovoltaic radiometer developed in the solar energy department

    Get PDF
    En este trabajo se analiza el desempeño de un radiómetro fotovoltaico fabricado en el Departamento Energía Solar (DES) de la Comisión Nacional de Energía Atómica (CNEA) y se realiza la comparación con un piranómetro clase B. Ambos sensores calibrados se montaron en una estructura con un ángulo de inclinación que permite registrar la radiación incidente en ese plano. Los datos se recolectaron durante un periodo de doce meses utilizando un sistema de adquisición comercial que fue automatizado específicamente para la aplicación. El muestreo se realizó cada un segundo, se almacenó el promedio cada un minuto junto con su desviación estándar. La metodología consistió primeramente en calcular las diferencias porcentuales entre las mediciones del piranómetro de referencia clase B y el sensor fotovoltaico. Luego se prepararon dos series de datos con los registros de radiación horaria de cada uno de los sensores. Con estas series se simuló un sistema fotovoltaico conectado a la red de 85 kW. Los resultados mostraron que para los valores de rendimiento energético mensual las diferencias entre ambas simulaciones no superaron el 4 % salvo para el mes de diciembre donde se obtuvo una diferencia del 11 %. Para la mayoría de los meses la diferencia porcentual obtenida es menor al error del simulador. En el caso del rendimiento anual el porcentaje de diferencia que se obtuvo fue de 2% siendo el error del simulador del orden del 3%.The performance of a custom design photovoltaic sensor is presented in this paper. The photovoltaic sensors are made by the Energy Department of the National Commission of Atomic Energy in Argentine. The objective of the work was to analyze the performance of the sensor to use it in energy yield calculations for photovoltaic systems. The custom-made sensor was compared with a class B commercial pyranometer. Both sensors were calibrated and mounted in a structure with and angle of 34° to measure the radiation of the plane of an array installed in the roof of the building. Data were collected for 12 months with a commercial datalogger which was automatized for this application. The sampling was set to one second and while recording each minute the instantaneous value, the mean value of the interval selected and its standard deviation. There were analyzed the distribution of the percentual difference between the photovoltaic sensor and the class B pyranometer hourly integrals and daily integrals and their behavior with the clear sky index and zenith angle. Once the measurements of the solar radiation in the plane of array were characterized the weather series were built. An 85-kW photovoltaic system connected to the grid was simulated using the measurements of the pyranometer and the photovoltaic sensor. The percentual differences found in the monthly energy yield were up to 4 % but December. The annual energy yield percentual difference was up to 2 % being the simulator error in the order of 3 %.Fil: Videla, M. E.. Comision Nacional de Energía Atómica. Gerencia del Área de Investigación y Aplicaciones no Nucleares. Gerencia Física (CAC). Grupo Energía Solar; ArgentinaFil: Martinez Bogado, Mónica Gladys. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comision Nacional de Energía Atómica. Gerencia del Área de Investigación y Aplicaciones no Nucleares. Gerencia Física (CAC). Grupo Energía Solar; ArgentinaFil: Tamasi, Mariana Julia Luisa. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Oficina de Coordinacion Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia - Nodo Constituyentes | Comision Nacional de Energia Atomica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia - Nodo Constituyentes.; Argentina. Comision Nacional de Energía Atómica. Gerencia del Área de Investigación y Aplicaciones no Nucleares. Gerencia Física (CAC). Grupo Energía Solar; ArgentinaFil: Moreno, Analía Verónica. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Oficina de Coordinacion Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia - Nodo Constituyentes | Comision Nacional de Energia Atomica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia - Nodo Constituyentes.; Argentina. Comision Nacional de Energía Atómica. Gerencia del Área de Investigación y Aplicaciones no Nucleares. Gerencia Física (CAC). Grupo Energía Solar; ArgentinaFil: Kondratiuk, Nadia Yamila. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comision Nacional de Energía Atómica. Gerencia del Área de Investigación y Aplicaciones no Nucleares. Gerencia Física (CAC). Grupo Energía Solar; ArgentinaFil: Diaz Salazar, Martha. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comision Nacional de Energía Atómica. Gerencia del Área de Investigación y Aplicaciones no Nucleares. Gerencia Física (CAC). Grupo Energía Solar; Argentin

    Diseño, fabricación, caracterización y ensayos de sensores fotovoltaicos para la misión satelital Aquarius-SAC-D

    Get PDF
    La potencia eléctrica es uno de los recursos claves de los sistemas espaciales. Razón por la cual, los generadores solares fotovoltaicos han sido y continuarán siendo la mejor opción como fuente de potencia para satélites de órbita baja y geoestacionaria. Para orientar los paneles al sol se utilizan sensores primarios o sensores gruesos de posición, como parte del sistema de control de actitud del satélite y formando parte fundamental del sistema de orientación con respecto al Sol. En este trabajo se presenta el diseño, fabricación y ensayos de calificación tales como ensayos mecánicos sobre contactos y de daño por radiación. Se caracterizaron eléctricamente mediante la medición de la curva corriente-tensión (I-V) y electrónicamente a través de la medición de respuesta espectral y la determinación de la vida media de los portadores minoritarios empleando la técnica OCVD modificada. Estas caracterizaciones se realizaron antes y después del ensayo de daño por radiación con protones de 10 MeV incidencia normal y con una fluencia del orden de 1011 p/cm2.Electrical power is one of the main resources of the space systems. That is way, photovoltaic solar generator have been and will continue being the best choice as source of power for low and geostationary satellites. In order to orient the panels to the sun, coarse sun sensors are used as part of control system of satellite attitude, been a fundamental part of sun tracking system. In this work one appears the design, manufacture and qualification tests such as mechanical tests on contacts and radiation damage. Electrical and electronic characterization through I-V curved, spectral response measurement and determination of the effective lifetime of the minority carriers using modified OCVD technique were carried out. These characterizations were made before and after irradiation damage using 10 MeV protons´ at normal incidence and a fluence around 1011 p/cm2.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES

    Diseño, fabricación, caracterización y ensayos de sensores fotovoltaicos para la misión satelital Aquarius-SAC-D

    Get PDF
    La potencia eléctrica es uno de los recursos claves de los sistemas espaciales. Razón por la cual, los generadores solares fotovoltaicos han sido y continuarán siendo la mejor opción como fuente de potencia para satélites de órbita baja y geoestacionaria. Para orientar los paneles al sol se utilizan sensores primarios o sensores gruesos de posición, como parte del sistema de control de actitud del satélite y formando parte fundamental del sistema de orientación con respecto al Sol. En este trabajo se presenta el diseño, fabricación y ensayos de calificación tales como ensayos mecánicos sobre contactos y de daño por radiación. Se caracterizaron eléctricamente mediante la medición de la curva corriente-tensión (I-V) y electrónicamente a través de la medición de respuesta espectral y la determinación de la vida media de los portadores minoritarios empleando la técnica OCVD modificada. Estas caracterizaciones se realizaron antes y después del ensayo de daño por radiación con protones de 10 MeV incidencia normal y con una fluencia del orden de 1011 p/cm2.Electrical power is one of the main resources of the space systems. That is way, photovoltaic solar generator have been and will continue being the best choice as source of power for low and geostationary satellites. In order to orient the panels to the sun, coarse sun sensors are used as part of control system of satellite attitude, been a fundamental part of sun tracking system. In this work one appears the design, manufacture and qualification tests such as mechanical tests on contacts and radiation damage. Electrical and electronic characterization through I-V curved, spectral response measurement and determination of the effective lifetime of the minority carriers using modified OCVD technique were carried out. These characterizations were made before and after irradiation damage using 10 MeV protons´ at normal incidence and a fluence around 1011 p/cm2.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES

    Are exhaled nitric oxide measurements using the portable NIOX MINO repeatable?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Exhaled nitric oxide is a non-invasive marker of airway inflammation and a portable analyser, the NIOX MINO (Aerocrine AB, Solna, Sweden), is now available. This study aimed to assess the reproducibility of the NIOX MINO measurements across age, sex and lung function for both absolute and categorical exhaled nitric oxide values in two distinct groups of children and teenagers.</p> <p>Methods</p> <p>Paired exhaled nitric oxide readings were obtained from 494 teenagers, aged 16-18 years, enrolled in an unselected birth cohort and 65 young people, aged 6-17 years, with asthma enrolled in an interventional asthma management study.</p> <p>Results</p> <p>The birth cohort participants showed a high degree of variability between first and second exhaled nitric oxide readings (mean intra-participant difference 1.37 ppb, 95% limits of agreement -7.61 to 10.34 ppb), although there was very close agreement when values were categorised as low, normal, intermediate or high (kappa = 0.907, p < 0.001). Similar findings were seen in subgroup analyses by sex, lung function and asthma status. Similar findings were seen in the interventional study participants.</p> <p>Conclusions</p> <p>The reproducibility of exhaled nitric oxide is poor for absolute values but acceptable when values are categorised as low, normal, intermediate or high in children and teenagers. One measurement is therefore sufficient when using categorical exhaled nitric oxide values to direct asthma management but a mean of at least two measurements is required for absolute values.</p
    corecore