54 research outputs found

    Optimized Grad-Shafranov Reconstruction of a Magnetic Cloud Using STEREO-Wind Observations

    Get PDF
    We present results on the geometry of a magnetic cloud (MC) on 23 May 2007 from a comprehensive analysis of Wind and STEREO observations. We first apply a Grad – Shafranov reconstruction to the STEREO-A plasma and magnetic field data, delivered by the PLASTIC and IMPACT instruments. We then optimize the resulting field map with the aid of observations by Wind, which were made at the very outer boundary of the cloud, at a spacecraft angular separation of 6°. For the correct choice of reconstruction parameters such as axis orientation, interval and grid size, we find both a very good match between the predicted magnetic field at the position of Wind and the actual observations as well as consistent timing. We argue that the reconstruction captures almost the full extent of the cross-section of the cloud. The resulting shape transverse to the invariant axis consists of distorted ellipses and is slightly flattened in the direction of motion. The MC axis is inclined at −58° to the ecliptic with an axial field strength of 12 nT. We derive integrated axial fluxes and currents with increased precision, which we contrast with the results from linear force-free fitting. The helical geometry of the MC with almost constant twist (≈1.5 turns AU−1) is not consistent with the linear force-free Lundquist model. We also find that the cloud is non-force-free (|J ⊥ |/|J ∥ |\u3e0.3) in about a quarter of the cloud cross sectional area, particularly in the back part which is interacting with the trailing high speed stream. Based on the optimized reconstruction we put forward preliminary guidelines for the improved use of single-spacecraft Grad – Shafranov reconstruction. The results also give us the opportunity to compare the CME direction inferred from STEREO/SECCHI observations by Mierla et al. (Solar Phys. 252, 385, 2008) with the three-dimensional configuration of the MC at 1 AU. This yields an almost radial CME propagation from the Sun to the Earth

    Influenza virus infections in cats

    Get PDF
    In the past, cats were considered resistant to influenza. Today, we know that they are susceptible to some influenza A viruses (IAVs) originating in other species. Usually, the outcome is only subclinical infection or a mild fever. However, outbreaks of feline disease caused by canine H3N2 IAV with fever, tachypnoea, sneezing, coughing, dyspnoea and lethargy are occasionally noted in shelters. In one such outbreak, the morbidity rate was 100% and the mortality rate was 40%. Recently, avian H7N2 IAV infection occurred in cats in some shelters in the USA, inducing mostly mild respiratory disease. Furthermore, cats are susceptible to experimental infection with the human H3N2 IAV that caused the pandemic in 1968. Several studies indicated that cats worldwide could be infected by H1N1 IAV during the subsequent human pandemic in 2009. In one shelter, severe cases with fatalities were noted. Finally, the highly pathogenic avian H5N1 IAV can induce a severe, fatal disease in cats, and can spread via cat-to-cat contact. In this review, the Advisory Board on Cat Diseases (ABCD), a scientifically independent board of experts in feline medicine from 11 European countries, summarises current data regarding the aetiology, epidemiology, pathogenesis, clinical picture, diagnostics, and control of feline IAV infections, as well as the zoonotic risks

    Anthropogenic infection of cats during the 2020 covid-19 pandemic

    Get PDF
    COVID-19 is a severe acute respiratory syndrome (SARS) caused by a new coronavirus (CoV), SARS-CoV-2, which is closely related to SARS-CoV that jumped the animal–human species bar-rier and caused a disease outbreak in 2003. SARS-CoV-2 is a betacoronavirus that was first described in 2019, unrelated to the commonly occurring feline coronavirus (FCoV) that is an alphacoronavirus associated with feline infectious peritonitis (FIP). SARS-CoV-2 is highly contagious and has spread globally within a few months, resulting in the current pandemic. Felids have been shown to be susceptible to SARS-CoV-2 infection. Particularly in the Western world, many people live in very close contact with their pet cats, and natural infections of cats in COVID-19-positive households have been described in several countries. In this review, the European Advisory Board on Cat Diseases (ABCD), a scientifically independent board of experts in feline medicine from 11 European Countries, discusses the current status of SARS-CoV infections in cats. The review examines the host range of SARS-CoV-2 and human-to-animal transmissions, including infections in domestic and non-domestic felids, as well as mink-to-human/-cat transmission. It summarises current data on SARS-CoV-2 prevalence in domestic cats and the results of experimental infections of cats and provides expert opinions on the clinical relevance and prevention of SARS-CoV-2 infection in cats

    Radial evolution of the April 2020 stealth coronal mass ejection between 0.8 and 1 AU - Comparison of Forbush decreases at Solar Orbiter and near the Earth

    Get PDF
    Aims. We present observations of the first coronal mass ejection (CME) observed at the Solar Orbiter spacecraft on April 19, 2020, and the associated Forbush decrease (FD) measured by its High Energy Telescope (HET). This CME is a multispacecraft event also seen near Earth the next day. Methods. We highlight the capabilities of HET for observing small short-term variations of the galactic cosmic ray count rate using its single detector counters. The analytical ForbMod model is applied to the FD measurements to reproduce the Forbush decrease at both locations. Input parameters for the model are derived from both in situ and remote-sensing observations of the CME. Results. The very slow (~350 km/s) stealth CME caused a FD with an amplitude of 3 % in the low-energy cosmic ray measurements at HET and 2 % in a comparable channel of the Cosmic Ray Telescope for the Effects of Radiation (CRaTER) on the Lunar Reconnaissance Orbiter, as well as a 1 % decrease in neutron monitor measurements. Significant differences are observed in the expansion behavior of the CME at different locations, which may be related to influence of the following high speed solar wind stream. Under certain assumptions, ForbMod is able to reproduce the observed FDs in low-energy cosmic ray measurements from HET as well as CRaTER, but with the same input parameters, the results do not agree with the FD amplitudes at higher energies measured by neutron monitors on Earth. We study these discrepancies and provide possible explanations. Conclusions. This study highlights that the novel measurements of the Solar Orbiter can be coordinated with other spacecraft to improve our understanding of space weather in the inner heliosphere. Multi-spacecraft observations combined with data-based modeling are also essential to understand the propagation and evolution of CMEs as well as their space weather impacts

    Milk ejection disorders in Swiss dairy cows: a field study

    Get PDF
    A questionnaire was sent to 2099 dairy farms to investigate the occurrence of poor milkability. Based on that, the frequency of poor milkability in Swiss dairy cows was 4% and the percentage of cows treated with oxytocin (OT) was 2%. In addition, 270 dairy farms that had reported cases of animals with poor milkability were contacted for an interview to classify the disorders. Farmers suspected disturbed milk ejection in 52%, anatomical dysfunction of the teat and/or the udder in 16% and milk ejection disorder or impaired milkability caused by discernable environmental factors in 32% of the cases. Forty-eight animals from 18 farms with suspected milk ejection disorders were selected for an experimental field study which included milk flow recording and OT administration to induce milk ejection. After cessation of the spontaneous milk flow, a low dose of OT (0.2, 0.5 or 1 i.u.) was injected i.v. to test the responsiveness of the udder to OT at a physiological level. When milk flow ceased again, 10 i.u. OT was injected i.v. (supraphysiological) to ensure complete udder emptying and to determine the residual milk. Milk ejection disorder could be confirmed in 69% of the cases, i.e. if residual milk was >20% of the total milk. Because in 27% of the animals milk ejection disorder was not confirmed on the basis of elevated residual milk, an anatomical disorder of the teat and/or the udder was suspected. Milk ejection disorder could be confirmed in 69% of the cases whereas in 27% of the suspected cases an anatomical disorder of the teat and/or the udder was suspected. An increased cortisol production in cows with milk ejection disorder was not obvious because faecal concentrations of cortisol metabolites with a 5 beta-androstane-3 alpha,11 oxo-structure were not augmented in animals with disturbed milk ejection
    • …
    corecore