971 research outputs found

    Light yield determination in large sodium iodide detectors applied in the search for dark matter

    Get PDF
    Application of NaI(Tl) detectors in the search for galactic dark matter particles through their elastic scattering off the target nuclei is well motivated because of the long standing DAMA/LIBRA highly significant positive result on annual modulation, still requiring confirmation. For such a goal, it is mandatory to reach very low threshold in energy (at or below the keV level), very low radioactive background (at a few counts/keV/kg/day), and high detection mass (at or above the 100 kg scale). One of the most relevant technical issues is the optimization of the crystal intrinsic scintillation light yield and the efficiency of the light collecting system for large mass crystals. In the frame of the ANAIS (Annual modulation with NaI Scintillators) dark matter search project large NaI(Tl) crystals from different providers coupled to two photomultiplier tubes (PMTs) have been tested at the Canfranc Underground Laboratory. In this paper we present the estimates of the NaI(Tl) scintillation light collected using full-absorption peaks at very low energy from external and internal sources emitting gammas/electrons, and single-photoelectron events populations selected by using very low energy pulses tails. Outstanding scintillation light collection at the level of 15~photoelectrons/keV can be reported for the final design and provider chosen for ANAIS detectors. Taking into account the Quantum Efficiency of the PMT units used, the intrinsic scintillation light yield in these NaI(Tl) crystals is above 40~photoelectrons/keV for energy depositions in the range from 3 up to 25~keV. This very high light output of ANAIS crystals allows triggering below 1~keV, which is very important in order to increase the sensitivity in the direct detection of dark matter

    Background analysis and status of the ANAIS dark matter project

    Full text link
    ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The comparison of the background model for the ANAIS-25 prototypes with the experimental results is presented. ANAIS crystal radiopurity goals have been achieved for Th-232 and U-238 chains, but a Pb-210 contamination out-of-equilibrium was identified, whose origin has been studied. The high light collection efficiency obtained with these prototypes allows to anticipate an energy threshold of the order of 1 keVee. A new detector, with improved performances, was received in March 2015 and very preliminary results are shown.Comment: 6 pages, 7 figure

    Preliminary results of ANAIS-25

    Get PDF
    The ANAIS (Annual Modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory. 250 kg of ultrapure NaI(Tl) crystals will be used as a target, divided into 20 modules, each coupled to two photomultipliers. Two NaI(Tl) crystals of 12.5 kg each, grown by Alpha Spectra from a powder having a potassium level under the limit of our analytical techniques, form the ANAIS-25 set-up. The background contributions are being carefully studied and preliminary results are presented: their natural potassium content in the bulk has been quantified, as well as the uranium and thorium radioactive chains presence in the bulk through the discrimination of the corresponding alpha events by PSA, and due to the fast commissioning, the contribution from cosmogenic activated isotopes is clearly identified and their decay observed along the first months of data taking. Following the procedures established with ANAIS-0 and previous prototypes, bulk NaI(Tl) scintillation events selection and light collection efficiency have been also studied in ANAIS-25.Comment: 4 pages, 6 Figure

    Integral field spectroscopy of type-II QSOs at z=0.3-0.4

    Get PDF
    We present and analyse integral-field observations of six type-II QSOs with z=0.3-0.4, selected from the Sloan Digital Sky Survey (SDSS). Two of our sample are found to be surrounded by a nebula of warm ionized gas, with the largest nebula extending across 8" (40 kpc). Some regions of the extended nebulae show kinematics that are consistent with gravitational motion, while other regions show relatively perturbed kinematics: velocity shifts and line widths too large to be readily explained by gravitational motion. We propose that a ~20 kpc x20 kpc outflow is present in one of the galaxies. Possible mechanisms for triggering the outflow are discussed. In this object, we also find evidence for ionization both by shocks and the radiation field of the AGN.Comment: 6 pages, 5 figures, accepted by MNRAS Letter

    Bulk NaI(Tl) scintillation low energy events selection with the ANAIS-0 module

    Get PDF
    Dark matter particles scattering off some target nuclei are expected to deposit very small energies in form of nuclear recoils (below 100 keV). Because of the low scintillation efficiency for nuclear recoils vs. electron recoils, in most of the scintillating targets considered in the search for dark matter, the region below 10 keVee concentrates most of the expected dark matter signal. For this reason, very low energy threshold (at or below 2 keVee) and very low background are required. This is the case of the ANAIS (Annual modulation with NaI Scintillators) experiment. A good knowledge of the detector response function for real scintillation events, a good characterization of other anomalous or noise event populations contributing in that energy range, and the development of convenient filtering procedures for the latter are mandatory to achieve the required low background at such a low energy. In this work we will present the specific protocols developed to select bulk scintillation events in NaI(Tl), and its application to data obtained with the ANAIS-0 prototype. Slight differences in time constants are expected in scintillation pulses produced by nuclear or electron recoils in NaI(Tl), so in order to analyze the effect of these filtering procedures in the case of a recoil population attributable to dark matter, data from a neutron calibration have been used.Comment: 13 pages, 22 figure

    Nuevo género de avispa agallícola del encino, Kokkocynips Pujade-Villar & Melika, gen. n., con descripción de una nueva especies de México (Hymenoptera, Cynipidae)

    Get PDF
    A new genus of oak gallwasp, Kokkocynips Pujade-Villar & Melika gen.n., is described from Mexico. Diagnostic characters and generic limits of the new genus are discussed in detail. Galls were found on branches of Quercus acutifolia Née. Diagnostic characters, distribution and biology of the new species are described and illustrated.Se describe un nuevo género de cinípido agallícola, Kokkocynips Pujade-Villar & Melika n. gen. (Hymenoptera: Cynipidae: Cynipini) de México. Se discuten en detalle los caracteres diagnósticos y los límites genéricos de este nuevo género. Las agallas se encuentran en las ramas de Quercus acutifolia Née. Se describen e ilustran los caracteres diagnósticos, su distribución y la biología de la nueva especie

    Results of donor after cardiac death circulation activation: recuperation of spontaneous circulation analysis.

    Get PDF
    The activation procedure of a potential donor after cardiac death begins after recognition of a situation of unrecovered PCR patient meets the criteria donor after cardiac death. Still have to meet a number of medical conditions and logistical both for the potential donor becomes effective donor. The aim of this study is to describe this procedure and know the number of potential donors who finally become effective donors. Method: Collection of all activations procedure after cardiac death donor HU 12 de Octubre for 5 years (2009-2013). Data collection is performed on a web platform created for this purpose.post-print255 K
    corecore