40 research outputs found

    Nanocasting Synthesis of Ultrafine WO3 Nanoparticles for Gas Sensing Applications

    Get PDF
    Ultrafine WO3 nanoparticles were synthesized by nanocasting route, using mesoporous SiO2 as a template. BET measurements showed a specific surface area of 700 m 2/gr for synthesized SiO2, while after impregnation and template removal, this area was reduced to 43 m 2/gr for WO3 nanoparticles. HRTEM results showed single crystalline nanoparticles with average particle size of about 5 nm possessing a monoclinic structure, which is the favorite crystal structure for gas sensing applications. Gas sensor was fabricated by deposition of WO3 nanoparticles between electrodes via low frequency AC electrophoretic deposition. Gas sensing measurements showed that this material has a high sensitivity to very low concentrations of NO2 at 250Ā°C and 300Ā°C

    Circadian changes and sex-related differences in fetal heart rate parameters

    Get PDF
    BACKGROUND: Previous researchers have studied circadian changes in the fetal heart rate (FHR) on small sample sizes and in a strictly controlled environment. This study was undertaken to investigate these changes during the late second and third trimesters, using a portable fetal electrocardiogram recording device (Monica AN24) in pregnant women in home and hospital environments with unrestricted mobility. METHODS: This was a prospective cohort study of 54 pregnant women with uncomplicated singleton pregnancies between 25 and 40 weeks gestation. FHR recordings were made up to 16 h at home or in the hospital setting in the United Kingdom. FHR data over 90 min periods were averaged and the day (7:00 am-11:00 pm) and night (11:00 pm-7:00 am) data from the same individual were compared. Data were examined for evidence of sex-related differences. RESULTS: During the night, there was a significant reduction in basal heart rate (bFHR) and a significant increase in short term variation (STV) and long term variation (LTV) (Pā€‰<ā€‰0.05). Basal FHR decreased (Pā€‰<ā€‰0.002), whereas LTV increased (Pā€‰=ā€‰0.014) with advancing gestation. Male fetuses showed greater day: night variation than females regardless of gestation (Pā€‰=ā€‰0.014). There was a higher bFHR in fetuses monitored during the day in hospital (Pā€‰=ā€‰0.04). CONCLUSION: This study demonstrates that there are sex-, environment and time-related differences in the FHR parameters measured. These differences may need to be considered taken when interpreting FHR data

    Comparison of diurnal variations, gestational age and gender related differences in fetal heart rate (FHR) parameters between appropriate-for-gestational-age (AGA) and small-for-gestational-age (SGA) fetuses in the home environment

    Get PDF
    Objective To assess the influence of gender, time of the day and gestational age on fetal heart rate (FHR) parameters between appropriate-for-gestational-age (AGA) and small-for-gestational age (SGA) fetuses using a portable fetal ECG monitor employed in the home setting. Methods We analysed and compared the antenatal FHR data collected in the home setting on 61 healthy pregnant women with singleton pregnancies from 24 weeks gestation. Of the 61 women, 31 had SGA fetuses (estimated fetal weight below the tenth gestational centile) and 30 were pregnant with AGA fetuses. FHR recordings were collected for up to 20 h. Two 90 min intervals were deliberately chosen retrospectively with respect to signal recording quality, one during day-time and one at night-time for comparison. Results Overall, success rate of the fetal abdominal ECG in the AGA fetuses was 75.7% compared to 48.6% in the SGA group. Based on randomly selected episodes of heart rate traces where recording quality exceeded 80% we were able to show a marginal difference between day and night-time recordings in AGA vs. SGA fetuses beyond 32 weeks of gestation. A selection bias in terms of covering different representation periods of fetal behavioural states cannot be excluded. In contrast to previous studies, we neither controlled maternal diet and activity nor measured maternal blood hormone and heart rate as all mothers were monitored in the home environment. Conclusion Based on clinically unremarkable, but statistically significant differences in the FHR parameters between the AGA and SGA group we suggest that further studies with large sample size are required to assess the clinical value of antenatal fetal ECG monitoring

    Template-based Quality Assessment of the Doppler Ultrasound Signal for Fetal Monitoring

    No full text
    One dimensional Doppler Ultrasound (DUS) is a low cost method for fetal auscultation. However, accuracy of any metrics derived from the DUS signals depends on their quality, which relies heavily on operator skills. In low resource settings, where skill levels are sparse, it is important for the device to provide real time signal quality feedback to allow the re-recording of data. Retrospectively, signal quality assessment can help remove low quality recordings when processing large amounts of data. To this end, we proposed a novel template-based method, to assess DUS signal quality. Data used in this study were collected from 17 pregnant women using a low-cost transducer connected to a smart phone. Recordings were split into 1990 segments of 3.75 s duration, and hand labeled for quality by three independent annotators. The proposed template-based method uses Empirical Mode Decomposition (EMD) to allow detection of the fetal heart beats and segmentation into short, time-aligned temporal windows. Templates were derived for each 15 s window of the recordings. The DUS signal quality index (SQI) was calculated by correlating the segments in each window with the corresponding running template using four different pre-processing steps: (i) no additional preprocessing, (ii) linear resampling of each beat, (iii) dynamic time warping (DTW) of each beat and (iv) weighted DTW of each beat. The template-based SQIs were combined with additional features based on sample entropy and power spectral density. To assess the performance of the method, the dataset was split into training and test subsets. The training set was used to obtain the best combination of features for predicting the DUS quality using cross validation, and the test set was used to estimate the classification accuracy using bootstrap resampling. A median out of sample classification accuracy on the test set of 85.8% was found using three features; template-based SQI, sample entropy and the relative power in the 160 to 660 Hz range. The results suggest that the new automated method can reliably assess the DUS quality, thereby helping users to consistently record DUS signals with acceptable quality for fetal monitoring

    A review of fetal cardiac monitoring, with a focus on low- And middle-income countries

    No full text
    There is limited evidence regarding the utility of fetal monitoring during pregnancy, particularly during labor and delivery. Developed countries rely on consensus ā€˜best practicesā€™ of obstetrics and gynecology professional societies to guide their protocols and policies. Protocols are often driven by the desire to be as safe as possible and avoid litigation, regardless of the cost of downstream treatment. In high-resource settings, there may be a justification for this approach. In low-resource settings, in particular, interventions can be costly and lead to adverse outcomes in subsequent pregnancies. Therefore, it is essential to consider the evidence and cost of different fetal monitoring approaches, particularly in the context of treatment and care in low-to-middle income countries. This article reviews the standard methods used for fetal monitoring, with particular emphasis on fetal cardiac assessment, which is a reliable indicator of fetal well-being. An overview of fetal monitoring practices in low-to-middle income counties, including perinatal care access challenges, is also presented. Finally, an overview of how mobile technology may help reduce barriers to perinatal care access in low-resource settings is provided

    NO2 gas sensor fabrication through AC electrophoretic deposition from electrospun In2O3 nanoribbons

    No full text
    In this paper, electrospinning method was employed to fabricate polymer-ceramic composite fibers from solutions containing polyvinyl pyrrolidone (PVP) and In(NO3)(3)center dot xH(2)O. Upon firing the composite fibers at 600 degrees C, In2O3 nanoribbons with cross section around 250 nm were synthesized. Gas sensor was fabricated by deposition of In2O3 nanoribbons between the electrodes via AC electrophoretic deposition. Gas sensing measurements showed that this material has high response to very low concentrations of NO2 gas at 200 degrees C. (C) 2011 Elsevier BM. All rights reserved
    corecore