921 research outputs found

    SOME FORENSIC ASPECTS OF BALLISTIC IMAGING

    Get PDF
    Analysis of ballistics evidence (spent cartridge casings and bullets) has been a staple of forensic criminal investigation for almost a century. Computer-assisted databases of images of ballistics evidence have been used since the mid-1980s to help search for potential matches between pieces of evidence. In this article, we draw on the 2008 National Research Council Report Ballistic Imaging to assess the state of ballistic imaging technology. In particular, we discuss the feasibility of creating a national reference ballistic imaging database (RBID) from test-fires of all newly manufactured or imported firearms. A national RBID might aid in using crime scene ballistic evidence to generate investigative leads to a crime gun’s point of sale. We conclude that a national RBID is not feasible at this time, primarily because existing imaging methodologies have insufficient discriminatory power. We also examine the emerging technology of micro- stamping for forensic identification purposes: etching a known identifier on firearm or ammunition parts so that they can be directly read and recovered from crime scene evidence. Microstamping could provide a stronger basis for identification based on ballistic evidence than the status quo, but substantial further research is needed to thoroughly assess its practical viability

    Hemodynamic Effects of Entry and Exit Tear Size in Aortic Dissection Evaluated with In Vitro Magnetic Resonance Imaging and Fluid-Structure Interaction Simulation

    Full text link
    Understanding the complex interplay between morphologic and hemodynamic features in aortic dissection is critical for risk stratification and for the development of individualized therapy. This work evaluates the effects of entry and exit tear size on the hemodynamics in type B aortic dissection by comparing fluid-structure interaction (FSI) simulations with in vitro 4D-flow magnetic resonance imaging (MRI). A baseline patient-specific 3D-printed model and two variants with modified tear size (smaller entry tear, smaller exit tear) were embedded into a flow- and pressure-controlled setup to perform MRI as well as 12-point catheter-based pressure measurements. The same models defined the wall and fluid domains for FSI simulations, for which boundary conditions were matched with measured data. Results showed exceptionally well matched complex flow patterns between 4D-flow MRI and FSI simulations. Compared to the baseline model, false lumen flow volume decreased with either a smaller entry tear (-17.8 and -18.5 %, for FSI simulation and 4D-flow MRI, respectively) or smaller exit tear (-16.0 and -17.3 %). True to false lumen pressure difference (initially 11.0 and 7.9 mmHg, for FSI simulation and catheter-based pressure measurements, respectively) increased with a smaller entry tear (28.9 and 14.6 mmHg), and became negative with a smaller exit tear (-20.6 and -13.2 mmHg). This work establishes quantitative and qualitative effects of entry or exit tear size on hemodynamics in aortic dissection, with particularly notable impact observed on FL pressurization. FSI simulations demonstrate acceptable qualitative and quantitative agreement with flow imaging, supporting its deployment in clinical studies.Comment: Judith Zimmermann and Kathrin B\"aumler contributed equall

    Radiation Damage Effects on High-Purity Germanium Detectors

    Get PDF
    This research was sponsored by the National Science Foundation Grant NSF PHY-931478
    • …
    corecore