393 research outputs found
Assessing the Permeability of Engineered Capillary Networks in a 3D Culture
Many pathologies are characterized by poor blood vessel growth and reduced nutrient delivery to the surrounding tissue, introducing a need for tissue engineered blood vessels. Our lab has developed a 3D co-culture method to grow interconnected networks of pericyte-invested capillaries, which can anastamose with host vasculature following implantation to restore blood flow to ischemic tissues. However, if the engineered vessels contain endothelial cells (ECs) that are misaligned or contain wide junctional gaps, they may function improperly and behave more like the pathologic vessels that nourish tumors. The purpose of this study was to test the resistance to permeability of these networks in vitro, grown with different stromal cell types, as a metric of vessel functionality. A fluorescent dextran tracer was used to visualize transport across the endothelium and the pixel intensity was quantified using a customized MATLAB algorithm. In fibroblast-EC co-cultures, the dextran tracer easily penetrated through the vessel wall and permeability was high through the first 5 days of culture, indicative of vessel immaturity. Beyond day 5, dextran accumulated at the periphery of the vessel, with very little transported across the endothelium. Quantitatively, permeability dropped from initial levels of 61% to 39% after 7 days, and to 7% after 2 weeks. When ECs were co-cultured with bone marrow-derived mesenchymal stem cells (MSCs) or adipose-derived stem cells (AdSCs), much tighter control of permeability was achieved. Relative to the EC-fibroblast co-cultures, permeabilities were reduced 41% for the EC-MSC co-cultures and 50% for the EC-AdSC co-cultures after 3 days of culture. By day 14, these permeabilities decreased by 68% and 77% over the EC-fibroblast cultures. Co-cultures containing stem cells exhibit elevated VE-cadherin levels and more prominent EC-EC junctional complexes when compared to cultures containing fibroblasts. These data suggest the stromal cell identity influences the functionality and physiologic relevance of engineered capillary networks
Quantum-enhanced advanced LIGO detectors in the era of gravitational-wave astronomy
The Laser Interferometer Gravitational Wave Observatory (LIGO) has been directly detecting gravitational waves from compact binary mergers since 2015. We report on the first use of squeezed vacuum states in the direct measurement of gravitational waves with the Advanced LIGO H1 and L1 detectors. This achievement is the culmination of decades of research to implement squeezed states in gravitational-wave detectors. During the ongoing O3 observation run, squeezed states are improving the sensitivity of the LIGO interferometers to signals above 50 Hz by up to 3 dB, thereby increasing the expected detection rate by 40% (H1) and 50% (L1)
Sensitivity and performance of the Advanced LIGO detectors in the third observing run
On April 1st, 2019, the Advanced Laser Interferometer Gravitational-Wave Observatory (aLIGO), joined by the Advanced Virgo detector, began the third observing run, a year-long dedicated search for gravitational radiation. The LIGO detectors have achieved a higher duty cycle and greater sensitivity to gravitational waves than ever before, with LIGO Hanford achieving angle-averaged sensitivity to binary neutron star coalescences to a distance of 111 Mpc, and LIGO Livingston to 134 Mpc with duty factors of 74.6% and 77.0% respectively. The improvement in sensitivity and stability is a result of several upgrades to the detectors, including doubled intracavity power, the addition of an in-vacuum optical parametric oscillator for squeezed-light injection, replacement of core optics and end reaction masses, and installation of acoustic mode dampers. This paper explores the purposes behind these upgrades, and explains to the best of our knowledge the noise currently limiting the sensitivity of each detector
Point absorbers in Advanced LIGO
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nanometer scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduce the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power buildup in second generation gravitational wave detectors (dual-recycled Fabry–Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and, hence, limit GW sensitivity, but it suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises
Environmental Noise in Advanced LIGO Detectors
The sensitivity of the Advanced LIGO detectors to gravitational waves can be
affected by environmental disturbances external to the detectors themselves.
Since the transition from the former initial LIGO phase, many improvements have
been made to the equipment and techniques used to investigate these
environmental effects. These methods have aided in tracking down and mitigating
noise sources throughout the first three observing runs of the advanced
detector era, keeping the ambient contribution of environmental noise below the
background noise levels of the detectors. In this paper we describe the methods
used and how they have led to the mitigation of noise sources, the role that
environmental monitoring has played in the validation of gravitational wave
events, and plans for future observing runs
Sensitivity and Performance of the Advanced LIGO Detectors in the Third Observing Run
On April 1st, 2019, the Advanced Laser Interferometer Gravitational-Wave
Observatory (aLIGO), joined by the Advanced Virgo detector, began the third
observing run, a year-long dedicated search for gravitational radiation. The
LIGO detectors have achieved a higher duty cycle and greater sensitivity to
gravitational waves than ever before, with LIGO Hanford achieving
angle-averaged sensitivity to binary neutron star coalescences to a distance of
111 Mpc, and LIGO Livingston to 134 Mpc with duty factors of 74.6% and 77.0%
respectively. The improvement in sensitivity and stability is a result of
several upgrades to the detectors, including doubled intracavity power, the
addition of an in-vacuum optical parametric oscillator for squeezed-light
injection, replacement of core optics and end reaction masses, and installation
of acoustic mode dampers. This paper explores the purposes behind these
upgrades, and explains to the best of our knowledge the noise currently
limiting the sensitivity of each detector.Comment: 27 pages, 11 figures. v2 edits: minor wording changes, author
additions, and grayscale-friendly figure
Quantum correlations between the light and kilogram-mass mirrors of LIGO
Measurement of minuscule forces and displacements with ever greater precision
encounters a limit imposed by a pillar of quantum mechanics: the Heisenberg
uncertainty principle. A limit to the precision with which the position of an
object can be measured continuously is known as the standard quantum limit
(SQL). When light is used as the probe, the SQL arises from the balance between
the uncertainties of photon radiation pressure imposed on the object and of the
photon number in the photoelectric detection. The only possibility surpassing
the SQL is via correlations within the position/momentum uncertainty of the
object and the photon number/phase uncertainty of the light it reflects. Here,
we experimentally prove the theoretical prediction that this type of quantum
correlation is naturally produced in the Laser Interferometer
Gravitational-wave Observatory (LIGO). Our measurements show that the quantum
mechanical uncertainties in the phases of the 200 kW laser beams and in the
positions of the 40 kg mirrors of the Advanced LIGO detectors yield a joint
quantum uncertainty a factor of 1.4 (3dB) below the SQL. We anticipate that
quantum correlations will not only improve gravitational wave (GW)
observatories but all types of measurements in future
Quantum correlations between light and the kilogram-mass mirrors of LIGO
The measurement of minuscule forces and displacements with ever greater precision is inhibited by the Heisenberg uncertainty principle, which imposes a limit to the precision with which the position of an object can be measured continuously, known as the standard quantum limit. When light is used as the probe, the standard quantum limit arises from the balance between the uncertainties of the photon radiation pressure applied to the object and of the photon number in the photoelectric detection. The only way to surpass the standard quantum limit is by introducing correlations between the position/momentum uncertainty of the object and the photon number/phase uncertainty of the light that it reflects. Here we confirm experimentally the theoretical prediction that this type of quantum correlation is naturally produced in the Laser Interferometer Gravitational-wave Observatory (LIGO). We characterize and compare noise spectra taken without squeezing and with squeezed vacuum states injected at varying quadrature angles. After subtracting classical noise, our measurements show that the quantum mechanical uncertainties in the phases of the 200-kilowatt laser beams and in the positions of the 40-kilogram mirrors of the Advanced LIGO detectors yield a joint quantum uncertainty that is a factor of 1.4 (3 decibels) below the standard quantum limit. We anticipate that the use of quantum correlations will improve not only the observation of gravitational waves, but also more broadly future quantum noise-limited measurements
- …