981 research outputs found
Characteristics of Non-Fatal Attacks by Black Bears: Conterminous United States, 2000–2017
Attacks on humans by bears (Ursus spp.) have increased in recent decades, as both human and bear populations have increased. To help mitigate the risk of future attacks, it is important to understand the circumstances in past attacks. Information and analyses exist regarding fatal attacks by both American black bears (Ursus americanus) and brown bears (U. arctos) as well as non-fatal attacks by brown bears. No similarly thorough analyses on non-fatal attacks by black bears are available. Our study addressed this information gap by analyzing all (n = 210) agency-confirmed, non-fatal attacks by black bears in the 48 conterminous United States during 2000 to 2017. Most attacks were defensive (52%), while 15% were predatory and 33% were food-motivated. Of defensive attacks, 85% were by female bears, and 91% of those females had young. Of predatory attacks, 95% were by male bears, and of food-motivated attacks, 80% were by male bears. Forty percent of defensive attacks by female bears involved dogs (Canis lupus familiaris). Sixty-four percent had an attractant present during the attack and 74% indicated there were reports of property damage by bears or of bears getting a food-reward in the area prior to the attack. A classification and regression tree model show the highest proportion of severe attacks were among a female victim who was with a dog and who fought back during an attack. When compared with previous studies of fatal attacks by black bears, which are typically predatory attacks by male bears, our results illustrate clear differences between fatal and non-fatal attacks. Our study also lends evidence to the hypothesis that dogs can trigger defensive attacks by black bears. These results have implications for risk assessment, attack mitigation, and how we advise the public to respond to an attacking bear
Moderate hypothermia within 6 h of birth plus inhaled xenon versus moderate hypothermia alone after birth asphyxia (TOBY-Xe): a proof-of-concept, open-label, randomised controlled trial
Background Moderate cooling after birth asphyxia is associated with substantial reductions in death and disability, but additional therapies might provide further benefit. We assessed whether the addition of xenon gas, a promising novel therapy, after the initiation of hypothermia for birth asphyxia would result in further improvement. Methods Total Body hypothermia plus Xenon (TOBY-Xe) was a proof-of-concept, randomised, open-label, parallel-group trial done at four intensive-care neonatal units in the UK. Eligible infants were 36–43 weeks of gestational age, had signs of moderate to severe encephalopathy and moderately or severely abnormal background activity for at least 30 min or seizures as shown by amplitude-integrated EEG (aEEG), and had one of the following: Apgar score of 5 or less 10 min after birth, continued need for resuscitation 10 min after birth, or acidosis within 1 h of birth. Participants were allocated in a 1:1 ratio by use of a secure web-based computer-generated randomisation sequence within 12 h of birth to cooling to a rectal temperature of 33·5°C for 72 h (standard treatment) or to cooling in combination with 30% inhaled xenon for 24 h started immediately after randomisation. The primary outcomes were reduction in lactate to N-acetyl aspartate ratio in the thalamus and in preserved fractional anisotropy in the posterior limb of the internal capsule, measured with magnetic resonance spectroscopy and MRI, respectively, within 15 days of birth. The investigator assessing these outcomes was masked to allocation. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00934700, and with ISRCTN, as ISRCTN08886155. Findings The study was done from Jan 31, 2012, to Sept 30, 2014. We enrolled 92 infants, 46 of whom were randomly assigned to cooling only and 46 to xenon plus cooling. 37 infants in the cooling only group and 41 in the cooling plus xenon group underwent magnetic resonance assessments and were included in the analysis of the primary outcomes. We noted no significant differences in lactate to N-acetyl aspartate ratio in the thalamus (geometric mean ratio 1·09, 95% CI 0·90 to 1·32) or fractional anisotropy (mean difference −0·01, 95% CI −0·03 to 0·02) in the posterior limb of the internal capsule between the two groups. Nine infants died in the cooling group and 11 in the xenon group. Two adverse events were reported in the xenon group: subcutaneous fat necrosis and transient desaturation during the MRI. No serious adverse events were recorded. Interpretation Administration of xenon within the delayed timeframe used in this trial is feasible and apparently safe, but is unlikely to enhance the neuroprotective effect of cooling after birth asphyxia
Piezoelectricity: Quantized Charge Transport Driven by Adiabatic Deformations
We study the (zero temperature) quantum piezoelectric response of Harper-like
models with broken inversion symmetry. The charge transport in these models is
related to topological invariants (Chern numbers). We show that there are
arbitrarily small periodic modulations of the atomic positions that lead to
nonzero charge transport for the electrons.Comment: Latex, letter. Replaced version with minor change in style. 1 fi
Review of high-contrast imaging systems for current and future ground- and space-based telescopes I. Coronagraph design methods and optical performance metrics
The Optimal Optical Coronagraph (OOC) Workshop at the Lorentz Center in
September 2017 in Leiden, the Netherlands gathered a diverse group of 25
researchers working on exoplanet instrumentation to stimulate the emergence and
sharing of new ideas. In this first installment of a series of three papers
summarizing the outcomes of the OOC workshop, we present an overview of design
methods and optical performance metrics developed for coronagraph instruments.
The design and optimization of coronagraphs for future telescopes has
progressed rapidly over the past several years in the context of space mission
studies for Exo-C, WFIRST, HabEx, and LUVOIR as well as ground-based
telescopes. Design tools have been developed at several institutions to
optimize a variety of coronagraph mask types. We aim to give a broad overview
of the approaches used, examples of their utility, and provide the optimization
tools to the community. Though it is clear that the basic function of
coronagraphs is to suppress starlight while maintaining light from off-axis
sources, our community lacks a general set of standard performance metrics that
apply to both detecting and characterizing exoplanets. The attendees of the OOC
workshop agreed that it would benefit our community to clearly define
quantities for comparing the performance of coronagraph designs and systems.
Therefore, we also present a set of metrics that may be applied to theoretical
designs, testbeds, and deployed instruments. We show how these quantities may
be used to easily relate the basic properties of the optical instrument to the
detection significance of the given point source in the presence of realistic
noise.Comment: To appear in Proceedings of the SPIE, vol. 1069
High temperature piezoelectric properties of flux-grown α-GeO 2 single crystal
International audienceThe temperature-dependence of the piezoelectric properties of trigonal -GeO2 single-crystals obtained by the high-temperature flux method was measured by the resonance technique of the electrical impedance in the 20°C-600°C range. To approach the values of the two independent piezoelectric coefficients d11 and d14, we first measured as a function of temperature the elastic coefficients S11, S14 and S66 and the dielectric permittivity 11 which are involved in the coupling coefficient k of both the thickness shear mode and the transverse mode. A Y-cut plate with a simple +45°-rotation ((YXtwl) +45°/0°/0°) was used to measure the coupling coefficient of the thickness shear mode, and two X-turned plates ((XYtwl) +45°/0°/0° and (XYtwl)-45°/0°/0°) were prepared to characterize the coupling coefficient of two transverse modes. From the whole experimental measurements, the piezoelectric coefficients of -GeO2 were calculated up to 600 °C. They show that this crystal is one of the most efficient in regard of the -quartz-like family at room temperature, and that its thermal comportment retains large piezoelectric properties up to 600°C
Mars Science Laboratory Drill
This drill (see Figure 1) is the primary sample acquisition element of the Mars Science Laboratory (MSL) that collects powdered samples from various types of rock (from clays to massive basalts) at depths up to 50 mm below the surface. A rotary-percussive sample acquisition device was developed with an emphasis on toughness and robustness to handle the harsh environment on Mars. It is the first rover-based sample acquisition device to be flight-qualified (see Figure 2). This drill features an autonomous tool change-out on a mobile robot, and novel voice-coil-based percussion. The drill comprises seven subelements. Starting at the end of the drill, there is a bit assembly that cuts the rock and collects the sample. Supporting the bit is a subassembly comprising a chuck mechanism to engage and release the new and worn bits, respectively, and a spindle mechanism to rotate the bit. Just aft of that is a percussion mechanism, which generates hammer blows to break the rock and create the dynamic environment used to flow the powdered sample. These components are mounted to a translation mechanism, which provides linear motion and senses weight-on-bit with a force sensor. There is a passive-contact sensor/stabilizer mechanism that secures the drill fs position on the rock surface, and flex harness management hardware to provide the power and signals to the translating components. The drill housing serves as the primary structure of the turret, to which the additional tools and instruments are attached. The drill bit assembly (DBA) is a passive device that is rotated and hammered in order to cut rock (i.e. science targets) and collect the cuttings (powder) in a sample chamber until ready for transfer to the CHIMRA (Collection and Handling for Interior Martian Rock Analysis). The DBA consists of a 5/8-in. (.1.6- cm) commercial hammer drill bit whose shank has been turned down and machined with deep flutes designed for aggressive cutting removal. Surrounding the shank of the bit is a thick-walled maraging steel collection tube allowing the powdered sample to be augured up the hole into the sample chamber. For robustness, the wall thickness of the DBA was maximized while still ensuring effective sample collection. There are four recesses in the bit tube that are used to retain the fresh bits in their bit box. The rotating bit is supported by a back-to-back duplex bearing pair within a housing that is connected to the outer DBA housing by two titanium diaphragms. The only bearings on the drill in the sample flow are protected by a spring-energized seal, and an integrated shield that diverts the ingested powdered sample from the moving interface. The DBA diaphragms provide radial constraint of the rotating bit and form the sample chambers. Between the diaphragms there is a sample exit tube from which the sample is transferred to the CHIMRA. To ensure that the entire collected sample is retained, no matter the orientation of the drill with respect to gravity during sampling, the pass-through from the forward to the aft chamber resides opposite to the exit tube
Tropospheric methanol observations from space: retrieval evaluation and constraints on the seasonality of biogenic emissions
Methanol retrievals from nadir-viewing space-based sensors offer powerful new information for quantifying methanol emissions on a global scale. Here we apply an ensemble of aircraft observations over North America to evaluate new methanol measurements from the Tropospheric Emission Spectrometer (TES) on the Aura satellite, and combine the TES data with observations from the Infrared Atmospheric Sounding Interferometer (IASI) on the MetOp-A satellite to investigate the seasonality of methanol emissions from northern midlatitude ecosystems. Using the GEOS-Chem chemical transport model as an intercomparison platform, we find that the TES retrieval performs well when the degrees of freedom for signal (DOFS) are above 0.5, in which case the model : TES regressions are generally consistent with the model : aircraft comparisons. Including retrievals with DOFS below 0.5 degrades the comparisons, as these are excessively influenced by the a priori. The comparisons suggest DOFS > 0.5 as a minimum threshold for interpreting retrievals of trace gases with a weak tropospheric signal. We analyze one full year of satellite observations and find that GEOS-Chem, driven with MEGANv2.1 biogenic emissions, underestimates observed methanol concentrations throughout the midlatitudes in springtime, with the timing of the seasonal peak in model emissions 1-2 months too late. We attribute this discrepancy to an underestimate of emissions from new leaves in MEGAN, and apply the satellite data to better quantify the seasonal change in methanol emissions for midlatitude ecosystems. The derived parameters (relative emission factors of 11.0, 1.0, 0.05 and 8.6 for new, growing, mature, and old leaves, respectively, plus a leaf area index activity factor of 0.75 for expanding canopies with leaf area index < 2.0) provide a more realistic simulation of seasonal methanol concentrations in midlatitudes on the basis of IASI, TES, and ground-based measurements
HCOOH measurements from space: TES retrieval algorithm and observed global distribution
Presented is a detailed description of the TES (Tropospheric Emission Spectrometer)-Aura satellite formic acid
(HCOOH) retrieval algorithm and initial results quantifying the global
distribution of tropospheric HCOOH. The retrieval strategy, including the
optimal estimation methodology, spectral microwindows, a priori constraints,
and initial guess information, are provided. A comprehensive error and
sensitivity analysis is performed in order to characterize the retrieval
performance, degrees of freedom for signal, vertical resolution, and limits
of detection. These results show that the TES HCOOH retrievals (i) typically
provide at best 1.0 pieces of information; (ii) have the most vertical
sensitivity in the range from 900 to 600 hPa with ~ 2 km vertical
resolution; (iii) require at least 0.5 ppbv (parts per billion by volume) of HCOOH for detection if
thermal contrast is greater than 5 K, and higher concentrations as thermal
contrast decreases; and (iv) based on an ensemble of simulated retrievals,
are unbiased with a standard deviation of ±0.4 ppbv. The relative
spatial distribution of tropospheric HCOOH derived from TES and its
associated seasonality are broadly correlated with predictions from a
state-of-the-science chemical transport model (GEOS-Chem CTM). However, TES
HCOOH is generally higher than is predicted by GEOS-Chem, and this is in
agreement with recent work pointing to a large missing source of atmospheric
HCOOH. The model bias is especially pronounced in summertime and over biomass
burning regions, implicating biogenic emissions and fires as key sources of
the missing atmospheric HCOOH in the model
Resection of the liver for colorectal carcinoma metastases - A multi-institutional study of long-term survivors
In this review of a collected series of patients undergoing hepatic resection for colorectal metastases, 100 patients were found to have survived greater than five years from the time of resection. Of these 100 long-term survivors, 71 remain disease-free through the last follow-up, 19 recurred prior to five years, and ten recurred after five years. Patient characteristics that may have contributed to survival were examined. Procedures performed included five trisegmentectomies, 32 lobectomies, 16 left lateral segmentectomies, and 45 wedge resections. The margin of resection was recorded in 27 patients, one of whom had a positive margin, nine of whom had a less than or equal to 1-cm margin, and 17 of whom had a greater than 1-cm margin. Eighty-one patients had a solitary metastasis to the liver, 11 patients had two metastases, one patient had three metastases, and four patients had four metastases. Thirty patients had Stage C primary carcinoma, 40 had Stage B primary carcinoma, and one had Stage A primarycarcinoma. The disease-free interval from the time of colon resection to the time of liver resection was less than one year in 65 patients, and greater than one year in 34 patients. Three patients had bilobar metastases. Four of the patients had extrahepatic disease resected simultaneously with the liver resection. Though several contraindications to hepatic resection have been proposed in the past, five-year survival has been found in patients with extrahepatic disease resected simultaneously, patients with bilobar metastases, patients with multiple metastases, and patients with positive margins. Five-year disease-free survivors are also present in each of these subsets. It is concluded that five-year survival is possible in the presence of reported contraindications to resection, and therefore that the decision to resect the liver must be individualized. © 1988 American Society of Colon and Rectal Surgeons
Paving the Way to Future Missions: the Roman Space Telescope Coronagraph Technology Demonstration
This document summarizes how far the Nancy Grace Roman Space Telescope Coronagraph Instrument (Roman CGI) will go toward demonstrating high-contrast imaging and spectroscopic requirements for potential future exoplanet direct imaging missions, illustrated by the HabEx and LUVOIR concepts. The assessment is made for two levels of assumed CGI performance: (i) current best estimate (CBE) as of August 2020, based on laboratory results and realistic end-to-end simulations with JPL-standard Model Uncertainty Factors (MUFs); (ii) CGI design specifications inherited from Phase B requirements. We find that the predicted performance (CBE) of many CGI subsystems compares favorably with the needs of future missions, despite providing more modest point source detection limits than future missions. This is essentially due to the challenging pupil of the Roman Space Telescope; this pupil pushes the coronagraph masks sensitivities to misalignments to be commensurate with future missions. In particular, CGI will demonstrate active low-order wavefront control and photon counting capabilities at levels of performance either higher than, or comparable to, the needs of future missions
- …