270 research outputs found

    The cerebral and systemic kinetics of thiopentone and propofol in halothane anaesthetized sheep

    Get PDF
    Publisher's copy made available with the permission of the publisher © Australian Society of AnaesthetistsThe cerebral and systemic kinetics of intravenous thiopentone (250 mg over 2 minutes, n=5) and propofol (100 mg over 2 minutes, n=6) were determined in sheep anaesthetized with halothane (2.0%) and mechanically ventilated to an end-expired carbon dioxide tension of 40 mmHg. The sheep were previously instrumented with arterial and sagittal sinus (effluent from the brain) blood sampling catheters. Systemic kinetics were inferred from the time-course of the arterial blood concentrations, and cerebral kinetics from the time-course of the arterio-sagittal sinus concentration difference across the brain. Under halothane anaesthesia, the peak arterial concentrations of each drug occurred at the end of the two-minute infusion, and was 42.3 mg/l and 12.3 mg/l for thiopentone and propofol, respectively. Propofol had a significantly larger systemic clearance (3.19 l/min) than thiopentone (0.99 l/min). The brain concentrations of propofol equilibrated more slowly with the arterial concentrations than those of thiopentone. The extraction ratio across the brain near the end of the infusions (1.5 min) were 0.85 and 0.46 respectively. These data were also compared to analogous previously published data for initially conscious sheep. The systemic kinetics of thiopentone were little affected by halothane anaesthesia. For propofol, halothane anaesthesia was associated with a statistically significant reduction in clearance (50% of awake), a slower initial half-life (247% of awake), and the emergence of a second slower half-life in some sheep. The cerebral kinetics of both drugs were subtly altered by halothane anaesthesia.R. N. Upton, G. L. Ludbrook, C. Granthttp://www.aaic.net.au/Article.asp?D=200024

    Few-cycle soliton propagation

    Full text link
    Soliton propagation is usually described in the ``slowly varying envelope approximation'' (SVEA) regime, which is not applicable for ultrashort pulses. We present theoretical results and numerical simulations for both NLS and parametric (χ(2)\chi^{(2)}) ultrashort solitons in the ``generalised few-cycle envelope approximation'' (GFEA) regime, demonstrating their altered propagation.Comment: 4 pages, 4 figure

    Noise-free scattering of the quantized electromagnetic field from a dispersive linear dielectric

    Get PDF
    We study the scattering of the quantized electromagnetic field from a linear, dispersive dielectric using the scattering formalism for quantum fields. The medium is modeled as a collection of harmonic oscillators with a number of distinct resonance frequencies. This model corresponds to the Sellmeir expansion, which is widely used to describe experimental data for real dispersive media. The integral equation for the interpolating field in terms of the in field is solved and the solution used to find the out field. The relation between the in and out creation and annihilation operators is found which allows one to calculate the S-matrix for this system. In this model, we find that there are absorption bands, but the input-output relations are completely unitary. No additional quantum noise terms are required.Comment: Revtex, submitted to Physical Review

    Quantum-Noise Reduction in a Driven Cavity with Feedback

    Get PDF
    We show that amplitude-squeezed states may be produced by driving a feedback-controlled cavity with a coherent input signal. The feedback controls the transmissivity of one output from the cavity and is essentially equivalent to nonlinear absorption. The cavity effectively acts as a nonlinear reflector. Hence, amplitude-squeezed states with arbitrarily strong coherent intensities can be obtained

    Nonclassical statistics of intracavity coupled χ(2)\chi^{(2)} waveguides: the quantum optical dimer

    Get PDF
    A model is proposed where two χ(2)\chi^{(2)} nonlinear waveguides are contained in a cavity suited for second-harmonic generation. The evanescent wave coupling between the waveguides is considered as weak, and the interplay between this coupling and the nonlinear interaction within the waveguides gives rise to quantum violations of the classical limit. These violations are particularly strong when two instabilities are competing, where twin-beam behavior is found as almost complete noise suppression in the difference of the fundamental intensities. Moreover, close to bistable transitions perfect twin-beam correlations are seen in the sum of the fundamental intensities, and also the self-pulsing instability as well as the transition from symmetric to asymmetric states display nonclassical twin-beam correlations of both fundamental and second-harmonic intensities. The results are based on the full quantum Langevin equations derived from the Hamiltonian and including cavity damping effects. The intensity correlations of the output fields are calculated semi-analytically using a linearized version of the Langevin equations derived through the positive-P representation. Confirmation of the analytical results are obtained by numerical simulations of the nonlinear Langevin equations derived using the truncated Wigner representation.Comment: 15 pages, 8 figures, submitted to Phys. Rev.

    Systematic review of economic evaluations and cost analyses of guideline implementation strategies

    Get PDF
    Objectives To appraise the quality of economic studies undertaken as part of evaluations of guideline implementation strategies; determine their resources use; and recommend methods to improve future studies. Methods Systematic review of economic studies undertaken alongside robust study designs of clinical guideline implementation strategies published (1966-1998). Studies assessed against the BMJ economic evaluations guidelines for each stage of the guideline process (guideline development, implementation and treatment). Results 235 studies were identified, 63 reported some information on cost. Only 3 studies provided evidence that their guideline was effective and efficient. 38 reported the treatment costs only, 12 implementation and treatment costs, 11 implementation costs alone, and two guideline development, implementation and treatment costs. No study gave reasonably complete information on costs. Conclusions Very few satisfactory economic evaluations of guideline implementation strategies have been performed. Current evaluations have numerous methodological defects and rarely consider all relevant costs and benefits. Future evaluations should focus on evaluating the implementation of evidence based guidelines. Keywords: Cost-effectiveness analysis, physician (or health care professional) behaviour, practice guidelines, quality improvement, systematic review.Peer reviewedAuthor versio

    Renal Foreign Bodies

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/67109/2/10.1177_000992286900800511.pd

    Bose-Einstein condensate collapse: a comparison between theory and experiment

    Full text link
    We solve the Gross-Pitaevskii equation numerically for the collapse induced by a switch from positive to negative scattering lengths. We compare our results with experiments performed at JILA with Bose-Einstein condensates of Rb-85, in which the scattering length was controlled using a Feshbach resonance. Building on previous theoretical work we identify quantitative differences between the predictions of mean-field theory and the results of the experiments. Besides the previously reported difference between the predicted and observed critical atom number for collapse, we also find that the predicted collapse times systematically exceed those observed experimentally. Quantum field effects, such as fragmentation, that might account for these discrepancies are discussed.Comment: 4 pages, 2 figure
    corecore