170 research outputs found

    BCS to Bose Crossover in Anisotropic Superconductors

    Full text link
    In this work we use functional integral techniques to examine the nearest neighbour attractive Hubbard model on a quasi-2D lattice. It is a simple phenomenological model for the high-Tc cuprates that allows both extended (non-local) s- and d-wave singlet superconductivity as well as mixed symmetry states. The Hartree-Gor'kov mean field theory of the model has a finite temperature phase diagram which shows a transition from pure s-wave to pure d-wave superconductivity, via a mixed symmetry s+id state, as a function of doping. Including Gaussian fluctuations we examine the crossover from weak-coupling BCS superconductivity to the strong-coupling Bose-Einstein condensation of composite s- or d-wave bosons and comment on the origin and symmetry of the pseudogap.Comment: 20 pages inc. 13 figure

    The design of a project to assess bilateral versus unilateral hearing aid fitting

    Get PDF
    Binaural hearing provides advantages over monaural in several ways, particularly in difficult listening situations. For a person with bilateral hearing loss, the bilateral fitting of hearing aids thus seems like a natural choice. However, surprisingly few studies have been reported in which the additional benefit of bilateral versus unilateral hearing aid use has been investigated based on real-life experiences. Therefore, a project has been designed to address this issue and to find tools to identify people for whom the drawbacks would outweigh the advantages of bilateral fitting. A project following this design is likely to provide reliable evidence concerning differences in benefit between unilateral and bilateral fitting of hearing aids by evaluating correlations between entrance data and outcome measures and final preferences

    Subleading-twist effects in single-spin asymmetries in semi-inclusive deep-inelastic scattering on a longitudinally polarized hydrogen target

    Get PDF
    Single-spin asymmetries in the semi-inclusive production of charged pions in deep-inelastic scattering from transversely and longitudinally polarized proton targets are combined to evaluate the subleading-twist contribution to the longitudinal case. This contribution is significantly positive for (\pi^+) mesons and dominates the asymmetries on a longitudinally polarized target previously measured by \hermes. The subleading-twist contribution for (\pi^-) mesons is found to be small

    First Measurement of the Tensor Structure Function b1b_1 of the Deuteron

    Full text link
    The \Hermes experiment has investigated the tensor spin structure of the deuteron using the 27.6 GeV/c positron beam of \Hera. The use of a tensor polarized deuteron gas target with only a negligible residual vector polarization enabled the first measurement of the tensor asymmetry \At and the tensor structure function \bd for average values of the Bj{\o}rken variable 0.01<0.450.01<0.45 and of the squared four-momentum transfer 0.5GeV2<5GeV20.5 {\rm GeV^2} <5 {\rm GeV^2}. The quantities \At and \bd are found to be non-zero. The rise of \bd for decreasing values of xx can be interpreted to originate from the same mechanism that leads to nuclear shadowing in unpolarized scattering

    Double hadron leptoproduction in the nuclear medium

    Full text link
    First measurement of double-hadron production in deep-inelastic scattering has been measured with the HERMES spectrometer at HERA using a 27.6 GeV positron beam with deuterium, nitrogen, krypton and xenon targets. The influence of the nuclear medium on the ratio of double-hadron to single-hadron yields has been investigated. Nuclear effects are clearly observed but with substantially smaller magnitude and reduced AA-dependence compared to previously measured single-hadron multiplicity ratios. The data are in fair agreement with models based on partonic or pre-hadronic energy loss, while they seem to rule out a pure absorptive treatment of the final state interactions. Thus, the double-hadron ratio provides an additional tool for studying modifications of hadronization in nuclear matter

    Real-Time Contrast Enhancement to Improve Speech Recognition

    Get PDF
    An algorithm that operates in real-time to enhance the salient features of speech is described and its efficacy is evaluated. The Contrast Enhancement (CE) algorithm implements dynamic compressive gain and lateral inhibitory sidebands across channels in a modified winner-take-all circuit, which together produce a form of suppression that sharpens the dynamic spectrum. Normal-hearing listeners identified spectrally smeared consonants (VCVs) and vowels (hVds) in quiet and in noise. Consonant and vowel identification, especially in noise, were improved by the processing. The amount of improvement did not depend on the degree of spectral smearing or talker characteristics. For consonants, when results were analyzed according to phonetic feature, the most consistent improvement was for place of articulation. This is encouraging for hearing aid applications because confusions between consonants differing in place are a persistent problem for listeners with sensorineural hearing loss

    A retrospective analysis of noise-induced hearing loss in the Dutch construction industry

    Get PDF
    Purpose Noise exposure is an important and highly prevalent occupational hazard in the construction industry. This study examines hearing threshold levels of a large population of Dutch construction workers and compares their hearing thresholds to those predicted by ISO-1999. Methods In this retrospective study, medical records of periodic occupational health examinations of 29,644 construction workers are analysed. Pure-tone audiometric thresholds of noise-exposed workers are compared to a non-exposed control group and to ISO-1999 predictions. Regression analyses are conducted to explore the relationship between hearing loss and noise intensity, noise exposure time and the use of hearing protection. Results Noise-exposed workers had greater hearing losses compared to their non-noise-exposed colleagues and to the reference population reported in ISO-1999. Noise exposure explained only a small proportion of hearing loss. When the daily noise exposure level rose from 80 dB(A) towards 96 dB(A), only a minor increase in hearing loss is shown. The relation of exposure time and hearing loss found was similar to ISO-1999 predictions when looking at durations of 10 years or more. For the first decade, the population medians show poorer hearing than predicted by ISO-1999. Discussion Duration of noise exposure was a better predictor than noise exposure levels, probably because of the limitations in noise exposure estimations. In this population, noise-induced hearing loss was already present at the beginning of employment and increased at the same rate as is predicted for longer exposure duration

    Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints

    Get PDF
    OBJECTIVES: To generate insight into the differences between utility measures EuroQol 5D (EQ-5D), Health Utilities Index Mark II (HUI2) and Mark III (HUI3) and their impact on the incremental cost-effectiveness ratio (ICER) for hearing aid fitting METHODS: Persons with hearing complaints completed EQ-5D, HUI2 and HUI3 at baseline and, when applicable, after hearing aid fitting. Practicality, construct validity, agreement, responsiveness and impact on the ICER were examined. RESULTS: All measures had high completion rates. HUI3 was capable of discriminating between clinically distinctive groups. Utility scores (n = 315) for EQ-5D UK and Dutch tariff (0.83; 0.86), HUI2 (0.77) and HUI3 (0.61) were significantly different, agreement was low to moderate. Change after hearing aid fitting (n = 70) for HUI2 (0.07) and HUI3 (0.12) was statistically significant, unlike the EQ-5D UK (0.01) and Dutch (0.00) tariff. ICERs varied from 647,209 euros/QALY for the EQ-5D Dutch tariff to 15,811 euros/QALY for HUI3. CONCLUSION: Utility scores, utility gain and ICERs heavily depend on the measure that is used to elicit them. This study indicates HUI3 as the instrument of first choice when measuring utility in a population with hearing complaints, but emphasizes the importance of a clear notion of what constitutes utility with regard to economic analyse

    Substituting abacavir for hyperlipidemia-associated protease inhibitors in HAART regimens improves fasting lipid profiles, maintains virologic suppression, and simplifies treatment

    Get PDF
    BACKGROUND: Hyperlipidemia secondary to protease inhibitors (PI) may abate by switching to anti-HIV medications without lipid effects. METHOD: An open-label, randomized pilot study compared changes in fasting lipids and HIV-1 RNA in 104 HIV-infected adults with PI-associated hyperlipidemia (fasting serum total cholesterol >200 mg/dL) who were randomized either to a regimen in which their PI was replaced by abacavir 300 mg twice daily (n = 52) or a regimen in which their PI was continued (n = 52) for 28 weeks. All patients had undetectable viral loads (HIV-1 RNA <50 copies/mL) at baseline and were naïve to abacavir and non-nucleoside reverse transcriptase inhibitors. RESULTS: At baseline, the mean total cholesterol was 243 mg/dL, low density lipoprotein (LDL)-cholesterol 149 mg/dL, high density lipoprotein (HDL)-cholesterol 41 mg/dL, and triglycerides 310 mg/dL. Mean CD4+ cell counts were 551 and 531 cells/mm(3 )in the abacavir-switch and PI-continuation arms, respectively. At week 28, the abacavir-switch arm had significantly greater least square mean reduction from baseline in total cholesterol (-42 vs -10 mg/dL, P < 0.001), LDL-cholesterol (-14 vs +5 mg/dL, P = 0.016), and triglycerides (-134 vs -36 mg/dL, P = 0.019) than the PI-continuation arm, with no differences in HDL-cholesterol (+0.2 vs +1.3 mg/dL, P = 0.583). A higher proportion of patients in the abacavir-switch arm had decreases in protocol-defined total cholesterol and triglyceride toxicity grades, whereas a smaller proportion had increases in these toxicity grades. At week 28, an intent-to treat: missing = failure analysis showed that the abacavir-switch and PI-continuation arms did not differ significantly with respect to proportion of patients maintaining HIV-1 RNA <400 or <50 copies/mL or adjusted mean change from baseline in CD4+ cell count. Two possible abacavir-related hypersensitivity reactions were reported. No significant changes in glucose, insulin, insulin resistance, C-peptide, or waist-to-hip ratios were observed in either treatment arm, nor were differences in these parameters noted between treatments. CONCLUSION: In hyperlipidemic, antiretroviral-experienced patients with HIV-1 RNA levels <50 copies/mL and CD4+ cell counts >500 cells/mm(3), substituting abacavir for hyperlipidemia-associated PIs in combination antiretroviral regimens improves lipid profiles and maintains virologic suppression over a 28-week period, and it simplifies treatment
    corecore