5 research outputs found

    Mammographic density: Comparison of visual assessment with fully automatic calculation on a multivendor dataset

    No full text
    To compare breast density (BD) assessment provided by an automated BD evaluator (ABDE) with that provided by a panel of experienced breast radiologists, on a multivendor dataset. Methods Twenty-one radiologists assessed 613 screening/ diagnostic digital mammograms from nine centers and six different vendors, using the BI-RADS a, b, c, and d density classification. The same mammograms were also evaluated by an ABDE providing the ratio between fibroglandular and total breast area on a continuous scale and, automatically, the BI-RADS score. A panel majority report (PMR) was used as reference standard. Agreement (Îș) and accuracy (proportion of cases correctly classified) were calculated for binary (BI-RADS a-b versus c-d) and 4-class classification. Results While the agreement of individual radiologists with the PMR ranged from Îș=0.483 to Îș=0.885, the ABDE correctly classified 563/613 mammograms (92 %). A substantial agreement for binary classification was found for individual reader pairs (Îș=0.620, standard deviation [SD]=0.140), individual versus PMR (Îș=0.736, SD=0.117), and individual versus ABDE (Îș=0.674, SD=0.095). Agreement between ABDE and PMR was almost perfect (Îș=0.831). Conclusions The ABDE showed an almost perfect agreement with a 21-radiologist panel in binary BD classification on a multivendor dataset, earning a chance as a reproducible alternative to visual evaluation

    Digital breast tomosynthesis (DBT): recommendations from the Italian College of Breast Radiologists (ICBR) by the Italian Society of Medical Radiology (SIRM) and the Italian Group for Mammography Screening (GISMa)

    Get PDF
    This position paper, issued by ICBR/SIRM and GISMa, summarizes the evidence on DBT and provides recommendations for its use. In the screening setting, DBT in adjunct to digital mammography (DM) increased detection rate by 0.5\u20132.7\u2030 and decreased false positives by 0.8\u20133.6% compared to DM alone in observational and double-testing experimental studies. The reduction in recall rate could be less prominent in those screening programs which already have low recall rates with DM. The increase in radiation exposure associated with DM/DBT protocols has been solved by the introduction of synthetic mammograms (sDM) reconstructed from DBT datasets. Thus, whenever possible, sDM/DBT should be preferred to DM/DBT. However, before introducing DBT as a routine screening tool for average-risk women, we should wait for the results of randomized controlled trials and for a statistically significant and clinically relevant reduction in the interval cancer rate, hopefully associated with a reduction in the advanced cancer rate. Otherwise, a potential for overdiagnosis and overtreatment cannot be excluded. Studies exploring this issue are ongoing. Screening of women at intermediate risk should follow the same recommendations, with particular protocols for women with previous BC history. In high-risk women, if mammography is performed as an adjunct to MRI or in the case of MRI contraindications, sDM/DBT protocols are suggested. Evidence exists in favor of DBT usage in women with clinical symptoms/signs and asymptomatic women with screen-detected findings recalled for work-up. The possibility to perform needle biopsy or localization under DBT guidance should be offered when DBT-only findings need characterization or surger

    Digital breast tomosynthesis (DBT): recommendations from the Italian College of Breast Radiologists (ICBR) by the Italian Society of Medical Radiology (SIRM) and the Italian Group for Mammography Screening (GISMa)

    Get PDF
    This position paper, issued by ICBR/SIRM and GISMa, summarizes the evidence on DBT and provides recommendations for its use. In the screening setting, DBT in adjunct to digital mammography (DM) increased detection rate by 0.5\u20132.7\u2030 and decreased false positives by 0.8\u20133.6% compared to DM alone in observational and double-testing experimental studies. The reduction in recall rate could be less prominent in those screening programs which already have low recall rates with DM. The increase in radiation exposure associated with DM/DBT protocols has been solved by the introduction of synthetic mammograms (sDM) reconstructed from DBT datasets. Thus, whenever possible, sDM/DBT should be preferred to DM/DBT. However, before introducing DBT as a routine screening tool for average-risk women, we should wait for the results of randomized controlled trials and for a statistically significant and clinically relevant reduction in the interval cancer rate, hopefully associated with a reduction in the advanced cancer rate. Otherwise, a potential for overdiagnosis and overtreatment cannot be excluded. Studies exploring this issue are ongoing. Screening of women at intermediate risk should follow the same recommendations, with particular protocols for women with previous BC history. In high-risk women, if mammography is performed as an adjunct to MRI or in the case of MRI contraindications, sDM/DBT protocols are suggested. Evidence exists in favor of DBT usage in women with clinical symptoms/signs and asymptomatic women with screen-detected findings recalled for work-up. The possibility to perform needle biopsy or localization under DBT guidance should be offered when DBT-only findings need characterization or surger