144 research outputs found

    Anatomic variations of the T2 nerve root (including the nerve of Kuntz) and their implications for sympathectomy

    Get PDF
    AbstractObjective: The aim of this study was to clarify the anatomic variations of the intrathoracic nerve of Kuntz, and this should help delineate the resection margins during video-assisted thoracic sympathectomy. Methods: Sixty-six thoracic sympathetic chains of 39 adult Korean cadavers were dissected on both sides of the thorax in 27 cadavers (54 sides) and on one side in 12 cadavers (12 sides). Results: The intrathoracic nerve was observed in 45 (68.2%) sides and was present bilaterally in 48.1% of cadavers. No intrathoracic nerve or ascending ramus communicans arising from the second thoracic nerve was observed in only 5 (7.6%) sides. The diameter of the intrathoracic nerve was 1.25 ± 0.55 mm on average. The arising point of the intrathoracic nerve from the second thoracic nerve was 7.3 mm on average from the sympathetic trunk. Presence of the stellate ganglion was noted in 56 (84.8%) sides, and 6 (9.1%) sides showed a single large ganglion formed by the stellate and the second thoracic sympathetic ganglia. The second thoracic sympathetic ganglion was most commonly located (50%) in the second intercostal space. Conclusion: The anatomic variations of the intrathoracic nerve of Kuntz and the second thoracic sympathetic ganglion were characterized in human cadavers. It is hoped that this study will help to improve the recurrence of symptoms caused by the intrathoracic nerve in an upper thoracic sympathectomy for hyperhidrosis.J Thorac Cardiovasc Surg 2002;123:498-50

    Tip-Enhanced Raman Scattering Imaging of Two-Dimensional Tungsten Disulfide with Optimized Tip Fabrication Process

    Get PDF
    We successfully achieve the tip-enhanced nano Raman scattering images of a tungsten disulfide monolayer with optimizing a fabrication method of gold nanotip by controlling the concentration of etchant in an electrochemical etching process. By applying a square-wave voltage supplied from an arbitrary waveform generator to a gold wire, which is immersed in a hydrochloric acid solution diluted with ethanol at various ratios, we find that both the conical angle and radius of curvature of the tip apex can be varied by changing the ratio of hydrochloric acid and ethanol. We also suggest a model to explain the origin of these variations in the tip shape. From the systematic study, we find an optimal condition for achieving the yield of similar to 60% with the radius of similar to 34 nm and the cone angle of similar to 35 degrees. Using representative tips fabricated under the optimal etching condition, we demonstrate the tip-enhanced Raman scattering experiment of tungsten disulfide monolayer grown by a chemical vapor deposition method with a spatial resolution of similar to 40 nm and a Raman enhancement factor of similar to 4,760. © The Author(s) 2017

    A childhood case of spinal tuberculosis misdiagnosed as muscular dystrophy

    Get PDF
    Tuberculosis is primarily a pulmonary disease, but extra-pulmonary manifestations are not uncommon, especially in children and adolescents. Ten percent of extra pulmonary tuberculosis localizes to the bones and joints, and 56% of such cases affect the spine. We treated a childhood case of spinal tuberculosis misdiagnosed as muscular dystrophy in a patient without specific constitutional symptoms. We report this case because the patient had an unusual presentation of spinal tuberculosis

    Palliative radiotherapy in patients with a symptomatic pelvic mass of metastatic colorectal cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate the palliative role of radiotherapy (RT) and define the effectiveness of chemotherapy combined with palliative RT (CCRT) in patients with a symptomatic pelvic mass of metastatic colorectal cancer.</p> <p>Methods</p> <p>From August 1995 to December 2007, 80 patients with a symptomatic pelvic mass of metastatic colorectal cancer were treated with palliative RT at Samsung Medical Center. Initial presenting symptoms were pain (68 cases), bleeding (18 cases), and obstruction (nine cases). The pelvic mass originated from rectal cancer in 58 patients (73%) and from colon cancer in 22 patients (27%). Initially 72 patients (90%) were treated with surgery, including 64 complete local excisions; 77% in colon cancer and 81% in rectal cancer. The total RT dose ranged 8-60 Gy (median: 36 Gy) with 1.8-8 Gy per fraction. When the <b>α/β </b>for the tumor was assumed to be 10 Gy for the biologically equivalent dose (BED), the median RT dose was 46.8 Gy<sub>10 </sub>(14.4-78). Twenty one patients (26%) were treated with CCRT. Symptom palliation was assessed one month after the completion of RT.</p> <p>Results</p> <p>Symptom palliation was achieved in 80% of the cases. During the median follow-up period of five months (1-44 months), 45% of the cases experienced reappearance of symptoms; the median symptom control duration was five months. Median survival after RT was six months. On univariate analysis, the only significant prognostic factor for symptom control duration was BED ≥40 Gy<sub>10 </sub>(p < 0.05), and CCRT was a marginally significant factor (p = 0.0644). On multivariate analysis, BED and CCRT were significant prognostic factors for symptom control duration (p < 0.05).</p> <p>Conclusions</p> <p>RT was an effective palliation method in patients with a symptomatic pelvic mass of metastatic colorectal cancer. For improvement of symptom control rate and duration, a BED ≥ 40 Gy<sub>10 </sub>is recommended when possible. Considering the low morbidity and improved symptom palliation, CCRT might be considered in patients with good performance status.</p

    Complete Fracture of Sirolimus-Eluting Stent in a Saphenous Vein Graft to Left Anterior Descending Artery

    Get PDF
    Coronary stent fractures have been suggested as a potential new mechanism of restenosis. The mechanical properties of stents were designed not only to prevent vessel recoil, but also to resist the mechanical stress of vessel movement over millions of cardiac cycles. We present a case in which mechanical stress may have contributed to the fracture of a stent implanted in a saphenous vein graft (SVG) to the left coronary artery. The patient was admitted due to chest pain 2 years after receiving a coronary artery bypass graft. A coronary angiography revealed the culprit vessel to be the SVG to the left coronary artery. The graft was stenosed and was stented with a sirolimus-eluting stent. A 6-month follow-up coronary angiography revealed 80% in-stent restenosis with stent fracture. We re-intervened by balloon angioplasty. This is the first report of sirolimus-eluting stent fracture combined with restenosis of SVG in Korea

    Comparison of CT and 18F-FDG PET for Detecting Peritoneal Metastasis on the Preoperative Evaluation for Gastric Carcinoma

    Get PDF
    OBJECTIVE: The aim of our study was to compare the accuracy of CT and (18)FFDG PET for detecting peritoneal metastasis in patients with gastric carcinoma. MATERIALS AND METHODS: One-hundred-twelve patients who underwent a histologic confirmative exam or treatment (laparotomy, n = 107; diagnostic laparoscopy, n = 4; peritoneal washing cytology, n = 1) were retrospectively enrolled. All the patients underwent CT and (18)F-FDG PET scanning for their preoperative evaluation. The sensitivities, specificities and accuracies of CT and (18)FFDG PET imaging for the detection of peritoneal metastasis were calculated and then compared using Fisher's exact probability test (p < 0.05), on the basis of the original preoperative reports. In addition, two board-certified radiologists and two board-certified nuclear medicine physicians independently reviewed the CT and PET scans, respectively. A receiver-operating characteristic curve analysis was performed to compare the diagnostic performance of CT and (18)F-FDG PET imaging for detecting peritoneal metastasis. RESULTS: Based on the original preoperative reports, CT and (18)F-FDG PET showed sensitivities of 76.5% and 35.3% (p = 0.037), specificities of 91.6% and 98.9% (p = 0.035), respectively, and equal accuracies of 89.3% (p = 1.0). The receptor operating characteristics curve analysis showed a significantly higher diagnostic performance for CT (Az = 0.878) than for PET (Az = 0.686) (p = 0.004). The interobserver agreement for detecting peritoneal metastasis was good (kappa value = 0.684) for CT and moderate (kappa value = 0.460) for PET. CONCLUSION: For the detection of peritoneal metastasis, CT was more sensitive and showed a higher diagnostic performance than PET, although CT had a relatively lower specificity than did PET.ope

    Sequential magnetic resonance spectroscopic changes in a patient with nonketotic hyperglycinemia

    Get PDF
    Nonketotic hyperglycinemia (NKH) is a rare inborn error of amino acid metabolism. A defect in the glycine cleavage enzyme system results in highly elevated concentrations of glycine in the plasma, urine, cerebrospinal fluid, and brain, resulting in glycine-induced encephalopathy and neuropathy. The prevalence of NKH in Korea is very low, and no reports of surviving patients are available, given the scarcity and poor prognosis of this disease. In the current study, we present a patient with NKH diagnosed on the basis of clinical features, biochemical profiles, and genetic analysis. Magnetic resonance spectroscopy (MRS) allowed the measurement of absolute glycine concentrations in different parts of the brain that showed a significantly increased glycine peak, consolidating the diagnosis of NKH. In additional, serial MRS follow-up showed changes in the glycine/creatinine ratios in different parts of the brain. In conclusion, MRS is an effective, noninvasive diagnostic tool for NKH that can be used to distinguish this disease from other glycine metabolism disorders. It may also be useful for monitoring NKH treatment
    corecore