16 research outputs found
Tenth and Twelfth Nerve Palsies in a Patient with Internal Carotid Artery Dissection Mistaken for Cervical Mass Lesion
Among the multiple causes for cranial nerve palsies, internal carotid artery dissection is rather uncommon. Patients usually present with unilateral head pain, Horner's syndrome, and signs of cerebral ischemia. We present the case of a 52-year-old male patient, who showed isolated palsies of the tenth and twelfth nerve without any other symptoms. Magnetic resonance imaging (T1) depicted a hyperintense lesion surrounding the internal carotid artery, which was mistaken for a cervical mass, and the patient underwent unnecessary surgical exploration of the neck. Angiography performed afterward could reveal the dissection of the internal carotid artery. This case shows that even in cases with mild and atypic symptoms, internal carotid artery dissection has always to be ruled out in lower cranial nerve palsies
Fixed and adaptive beamforming improves speech perception in noise in cochlear implant recipients equipped with the MED-EL SONNET audio processor
Objective: To determine the impact of the fixed and adaptive beamforming technology of the new MED-EL SONNET cochlear implant audio processor on speech perception in noise. Methods: The study cohort comprises 18 postlingually deafened adult cochlear implant recipients with at least six months of experience. Speech reception thresholds were measured with the Oldenburg Sentence Test in continuous, speech-shaped noise. Target sentences were presented in front of the listener, with noise sources placed at -135° and 135°, respectively. Outcome measures were the differences in speech reception threshold using omnidirectional, fixed and adaptive beamformer microphone settings. Results: The use of directional microphones significantly improved speech reception thresholds: fixed beamformer vs. omnidirectional: 4.3 dB (95%-CI [3.15.5]), p<0.0001adaptive beamformer vs. omnidirectional: 6.1 dB (95%-CI [4.97.3]), p<0.0001and adaptive beamformer vs. fixed beamformer: 1.8 dB (95%-CI [0.73.0]), p = 0.001. Conclusion: This study confirms the previously reported improvements in speech perception in noise of the fixed beamformer microphone setting and is the first to report significant improvements in speech perception in noise when applying the adaptive beamformer microphone settings of the SONNET audio processor. Cochlear implant users may be able to benefit from improved hearing performance especially in difficult listening situations
Fixed and adaptive beamforming improves speech perception in noise in cochlear implant recipients equipped with the MED-EL SONNET audio processor
Objective
To determine the impact of the fixed and adaptive beamforming technology of the new MED-EL SONNET cochlear implant audio processor on speech perception in noise.
Methods
The study cohort comprises 18 postlingually deafened adult cochlear implant recipients with at least six months of experience. Speech reception thresholds were measured with the Oldenburg Sentence Test in continuous, speech-shaped noise. Target sentences were presented in front of the listener, with noise sources placed at -135 and 135, respectively. Outcome measures were the differences in speech reception threshold using omnidirectional, fixed and adaptive beamformer microphone settings.
Results
The use of directional microphones significantly improved speech reception thresholds: fixed beamformer vs. omnidirectional: 4.3 dB (95%-CI [3.1; 5.5]), p<0.0001; adaptive beamformer vs. omnidirectional: 6.1 dB (95%-CI [4.9; 7.3]), p<0.0001; and adaptive beamformer vs. fixed beamformer: 1.8 dB (95%-CI [0.7; 3.0]), p = 0.001.
Conclusion
This study confirms the previously reported improvements in speech perception in noise of the fixed beamformer microphone setting and is the first to report significant improvements in speech perception in noise when applying the adaptive beamformer microphone settings of the SONNET audio processor. Cochlear implant users may be able to benefit from improved hearing performance especially in difficult listening situations.(VLID)479101
Medical, Technical and Audiological Outcomes of Hearing Rehabilitation with the Bonebridge Transcutaneous Bone-Conduction Implant: A Single-Center Experience
Bone-conduction implants are a standard therapeutic option for patients with conductive, unilateral, or mixed hearing loss who either do not tolerate conventional hearing aids or can benefit from surgery. The aim of this study was to evaluate long-term medical and technical outcomes, and audiological results with the Bonebridge transcutaneous bone-conduction implant. This retrospective study included all patients implanted with a bone-conduction hearing implant at a tertiary medical referral center between March 2012 and October 2018. Medical and technical outcomes included the mean length of implant usage, medical and technical complications (skin and wound infection, lack of benefit, technical failure), explantations and revisions, coupling approaches, implant failure rate, implant survival and the implant loss for added follow-up years. Auditory results were measured by functional hearing gain and the Freiburger monosyllabic test at 65 dB sound pressure level. Sixty-four patients were included in the study; five of these were implanted bilaterally (69 devices). Five unilaterally implanted patients were lost to follow-up. The mean follow-up was 27.1 months (range: 0.2 months–6.3 years). The mean implant usage was 25.9 months (range: 0.2 months–6.3 years). Fifty-seven implants (89.1%) were in use at the end of the follow-up period. Complications occurred in six ears (9.4%). Five implants (7.8%) were explanted without reimplantation. Device failure occurred in one implant (1.6%), which was possibly caused by recurrent head trauma. The rate of implant loss due to technical device failure (damage to device) was 1 per 72 follow-up years. The mean improvement on the Freiburger monosyllabic test (52.1%, p = 0.0001), and in functional hearing gain across frequencies (26.5 dB, p = 0.0001) was significant. This single-center follow-up reveals the medical and technical reliability of a transcutaneous bone-conduction implant for hearing rehabilitation because complication and revision rates were low. The majority of patients still used the device at the end of the observation period. Implantation resulted in favorable hearing outcomes in comparison to that of unaided conditions. Cautious patient selection mainly regarding co-morbidities, the history of chronic otologic diseases and proper surgical technique seems to be crucial in reducing complications
Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography
Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging. Recent studies have shown that cone beam computed tomography has advantages when imaging metal artifacts. Patients with hearing loss or vertigo, who have undergone stapedotomy, often present a challenge for otologic surgeons. Imaging studies can deliver crucial additional information. Methods: A retrospective analysis of imaging studies and clinical data in a tertiary care center were carried out. Forty-one patients with forty-five implanted ears were evaluated in the study. All included patients had been implanted with a platinum–fluoroplastic (n = 19) or titanium (n = 26) piston and subsequently had undergone imaging months or years after surgery for various reasons. Patients underwent computed tomography or cone beam computed tomography of the temporal bone depending on availability. Piston visualization, prosthesis length, vestibular intrusion and audiologic results were compared between the groups. Piston position on imaging studies were compared to intraoperative findings. Results: Functional length measurements of all prostheses were carried out with a mean error of −0.17 mm (±0.20). Platinum–fluoroplastic protheses were significantly underestimated in length compared to titanium prostheses. To analyze the material-dependent difference in the measurement errors of the imaging techniques the interaction was tested in an ANOVA model and showed no statistically significant result (p = 0.24). The blinded neuroradiologist viewed two implants, both platinum–fluoroplastic pistons, as located outside of the vestibule due to an underestimation of the prothesis length and the missing radiodensity of the lower end of the prosthesis. Conclusion: Surgeons and radiologists should be aware of the different types and radiologic features of stapes prostheses and the missing radiodensity of some protheses parts. Cone beam computed tomography is an imaging alternative with a potential advantage of reduced radiation in patients after stapes surgery suffering from vertigo or hearing loss to evaluate piston position
The Laryngoscope / Long-term outcome of hearing rehabilitation with an active middle ear implant
Objective
To assess the audiological and longterm medical and technical followup outcomes of an active middle ear implant.
Methods
This was a retrospective medical chart analysis of all patients provided with an active middle ear implant in a tertiary academic medical referral center between September 1, 1998, and July 31, 2015. Main outcome measures were medical and technical complications, revisions, reimplantations, explantations, coupling approaches, mean time of use, pre and postoperative hearing thresholds, functional hearing gain across frequencies (2504,000 Hz), and Freiburg monosyllablic word test at 65 dB.
Results
One hundred and three patients were identified. Fifteen were implanted bilaterally (n = 118 Vibrant Soundbridge devices [MEDEL, Innsbruck, Austria]). Seventyseven devices were implanted for sensorineural and 41 for mixed and conductive hearing loss. Patients used the implant for 6.7 years (range 0.7 months17.9 years) on average. Ninetyone patients (77.12%) were using the device at the end of the observation period. An overall complication rate of 16.1% was observed. The revision and explantation rates were higher for devices implanted between 2004 and 2006. The device failure rate was 3.4%. Audiological evaluation showed significant hearing gains for both hearing loss patient groups.
Conclusion
This longterm followup reveals the reliability of the active middle ear implant in a single center. Overall complication rate and device failure rate are acceptable. The complication rate was higher during implementation of alternative coupling approaches. The audiological benefit was satisfactory in patients with all hearing loss types. The majority of implanted patients used the implant at the end of the observation period.(VLID)341189
Association of Surgical Volume and Quality Management in Thyroid Surgery: A Two-Nation Multicenter Study.
BACKGROUND
High-volume caseload in thyroid surgery is associated with lower postoperative complication rates resulting to better outcomes. The aim of the present study was to investigate the correlation of the departments' annual number of thyroid surgeries on the adherence to consensus guidelines and on the implementation of measures for quality assurance.
METHODS
In 2016, we sent an anonymous electronic survey with questions related to the perioperative management in thyroid surgery to all directors of departments in operative medicine in Switzerland and Austria. We compared the pre- and postoperative management with the summarized recommendations of the four most frequently used consensus guidelines. Analogously, we analyzed the implementation of six measures for quality assurance related to thyroid surgery for each participating department. Using logistic regression analysis, we evaluated the correlation of number of guidelines respected and number of measures for quality assurance with the departments' annual number of surgeries performed. Furthermore, we evaluated the number of departments providing thyroid cancer surgery and their experience in neck dissection.
RESULTS
The management corresponded in 64.0% to the summarized recommendations. Adherence to the summarized recommendations and implementation of measures for quality assurance were significantly more likely with increasing numbers of surgeries performed (p = 0.049 and p < 0.001). Ninety-two departments provided thyroid cancer surgery, whereas 12/92 (13.0%) were not able to perform central and/or lateral neck dissection.
CONCLUSION
Consensus guidelines are insufficiently implemented within thyroid surgery, and quality management is associated with surgical volume
Impact of surgeons' experience and the single-shot perioperative antibiotic prophylaxis on outcome in stapedotomy.
BackgroundThe aim of this study was to evaluate whether surgeons´ experience and perioperative single-shot antibiotic prophylaxis affect outcome of patients undergoing stapes surgery.Patients and methodsWe retrospectively evaluated audiological outcomes and postoperative complications of 538 consecutive patients who underwent stapes surgery at a single tertiary referral center between 1990 and 2017. Effects of different clinical variables, including single-shot antibiotic prophylaxis and surgeons' experience on outcome were assessed.Results538 patients underwent 667 stapedotomies and postoperative complication rate was 7.5% (n = 50). Air conduction and air-bone gap closure improved significantly after surgery (14.2 ± 14.8 dB, p = 0.001; 14.5 ± 12.8 dB, p = 0.001). Multivariate analysis revealed that 6 years or less of surgical experience was independently associated with a higher incidence of persisting or recurrent conductive hearing loss (p = 0.033, OR 5.13) but perioperative application of antibiotics had no significant effect on outcome.ConclusionFirst, clinical outcome regarding persisting or recurrent conductive hearing loss caused by incus necrosis and prosthesis luxation is linked to surgical performance. This underlines the need for a meticulous training and supervision of less experienced surgeons performing stapes surgery. Second, our results do not support the need for perioperative antibiotic prophylaxis in stapes surgery. Potential standard limitations of retrospective cohort studies (selection bias, confusion bias etc.) could play a role in interpreting our results. However, the probability for these limitations is minimized due to the large patient sample
Demographic characteristics of the study population.
<p>Subject demographic data.</p