    The impact of chest CT body composition parameters on clinical outcomes in COVID-19 patients

    Get PDF
    We assessed the impact of chest CT body composition parameters on outcomes and disease severity at hospital presentation of COVID-19 patients, focusing also on the possible mediation of body composition in the relationship between age and death in these patients. Chest CT scans performed at hospital presentation by consecutive COVID-19 patients (02/27/2020-03/13/2020) were retrospectively reviewed to obtain pectoralis muscle density and total, visceral, and intermuscular adipose tissue areas (TAT, VAT, IMAT) at the level of T7-T8 vertebrae. Primary outcomes were: hospitalization, mechanical ventilation (MV) and/or death, death alone. Secondary outcomes were: C-reactive protein (CRP), oxygen saturation (SO2), CT disease extension at hospital presentation. The mediation of body composition in the effect of age on death was explored. Of the 318 patients included in the study (median age 65.7 years, females 37.7%), 205 (64.5%) were hospitalized, 68 (21.4%) needed MV, and 58 (18.2%) died. Increased muscle density was a protective factor while increased TAT, VAT, and IMAT were risk factors for hospitalization and MV/death. All these parameters except TAT had borderline effects on death alone. All parameters were associated with SO2 and extension of lung parenchymal involvement at CT; VAT was associated with CRP. Approximately 3% of the effect of age on death was mediated by decreased muscle density. In conclusion, low muscle quality and ectopic fat accumulation were associated with COVID-19 outcomes, VAT was associated with baseline inflammation. Low muscle quality partly mediated the effect of age on mortality.We assessed the impact of chest CT body composition parameters on outcomes and disease severity at hospital presentation of COVID-19 patients, focusing also on the possible mediation of body composition in the relationship between age and death in these patients. Chest CT scans performed at hospital presentation by consecutive COVID-19 patients (02/ 27/2020-03/13/2020) were retrospectively reviewed to obtain pectoralis muscle density and total, visceral, and intermuscular adipose tissue areas (TAT, VAT, IMAT) at the level of T7-T8 vertebrae. Primary outcomes were: hospitalization, mechanical ventilation (MV) and/or death, death alone. Secondary outcomes were: C-reactive protein (CRP), oxygen saturation (SO2), CT disease extension at hospital presentation. The mediation of body composition in the effect of age on death was explored. Of the 318 patients included in the study (median age 65.7 years, females 37.7%), 205 (64.5%) were hospitalized, 68 (21.4%) needed MV, and 58 (18.2%) died. Increased muscle density was a protective factor while increased TAT, VAT, and IMAT were risk factors for hospitalization and MV/death. All these parameters except TAT had borderline effects on death alone. All parameters were associated with SO2 and extension of lung parenchymal involvement at CT; VAT was associated with CRP. Approximately 3% of the effect of age on death was mediated by decreased muscle density. In conclusion, low muscle quality and ectopic fat accumulation were associated with COVID-19 outcomes, VAT was associated with baseline inflammation. Low muscle quality partly mediated the effect of age on mortality

    The International Robotic Antarctic Infrared Telescope (IRAIT)

    No full text
    Thanks to exceptional coldness, low sky brightness and low content of water vapour of the above atmosphere Dome C, one of the three highest peaks of the large Antarctic plateau, is likely to be the best site on Earth for thermal infrared observations (2.3-300 μm) as well as for the far infrared range (30 μm-1mm). IRAIT (International Robotic Antarctic Infrared Telescope) will be the first European Infrared telescope operating at Dome C. It will be delivered to Antarctica at the end of 2006, will reach Dome C at the end of 2007 and the first winter-over operation will start in spring 2008, IRAIT will offer a unique opportunity for astronomers to test and verify the astronomical quality of the site and it will be a useful test-instrument for a new generation of Antarctic telescopes and focal plane instrumentations. We give here a general overview of the project and of the logistics and transportation options adopted to facilitate the installation of IRAIT at Dome C. We summarize the results of the electrical, electronics and networking tests and of the sky polarization measurements carried out at Dome C during the 2005-2006 summer-campaign. We also present the 25 cm optical telescope (small-IRAIT project) that will installed at Dome C during the Antarctic summer 2006-2007 and that will start observations during the 2007 Antarctic winter when a member of the IRAIT collaboration will join the Italian-French Dome C winter-over team
    corecore