213 research outputs found

    Patient-reported physical activity questionnaires: A systematic review of content and format

    Get PDF
    Many patients with chronic illness are limited in their physical activities. This systematic review evaluates the content and format of patient-reported outcome (PRO) questionnaires that measure physical activity in elderly and chronically ill populations.status: publishe

    Laser Applications

    Get PDF
    Contains research objectives and reports on three research projects.Joint Services Electronics Programs (U. S. Army, U. S. Navy, and U. S. Air Force) under Contract DAAB07-71-C-0300U. S. Air Force Office of Scientific Research (Contract F44620-71-C-0051)Naval Air Systems Comman

    Validity of instruments to measure physical activity may be questionable due to a lack of conceptual frameworks: a systematic review

    Get PDF
    BACKGROUND: Regulators' guidance documents for the development and validation of patient reported outcomes (PROs) advise the use of conceptual frameworks, which outline the structure of the concept that a PRO aims to measure. It is unknown if currently available PROs are based on conceptual frameworks. This study, limited to a specific case, aimed (i) to identify conceptual frameworks of physical activity in chronic respiratory patients or similar populations (chronic heart disease patients or the elderly), and (ii) to assess if the development and validation of PROs to measure physical activity in these populations were based on a conceptual framework of physical activity. METHODS: Two systematic reviews were conducted through search in Medline, Embase, Psychinfo, and Cinahl databases up to January 2010. RESULTS: In the first review only 2 references, identified from 581 references about physical activity in the defined populations, provided a conceptual framework of physical activity in COPD patients. In the second review, out of 103 studies developing PROs to measure physical activity or related constructs, none of them was based on a conceptual framework of physical activity. CONCLUSIONS: These findings raise concerns about how the large body of evidence from studies that use physical activity PRO instruments should be evaluated by health care providers, guideline developers, and regulatory bodies

    The ELPAT Living Organ Donor Psychosocial Assessment Tool (EPAT): from 'What' to 'How' of Psychosocial Screening - a Pilot Study

    Get PDF
    Thorough psychosocial screening of donor candidates is required in order to minimize potential negative consequences and to strive for optimal safety within living donation programmes. We aimed to develop an evidence-based tool to standardize the psychosocial screening process. Key concepts of psychosocial screening were used to structure our tool: motivation and decision-making, personal resources, psychopathology, social resources, ethical and legal factors and information and risk processing. We (i) discussed how each item per concept could be measured, (ii) reviewed and rated available validated tools, (iii) where necessary developed new items, (iv) assessed content validity and (v) pilot-tested the new items. The resulting ELPAT living organ donor Psychosocial Assessment Tool (EPAT) consists of a selection of validated questionnaires (28 items in total), a semi-structured interview (43 questions) and a Red Flag Checklist. We outline optimal procedures and conditions for implementing this tool. The EPAT and user manual are available from the authors. Use of this tool will standardize the psychosocial screening procedure ensuring that no psychosocial issues are overlooked and ensure that comparable selection criteria are used and facilitate generation of comparable psychosocial data on living donor candidates.info:eu-repo/semantics/publishedVersio

    Validity and responsiveness of the Daily- and Clinical visit-PROactive Physical Activity in COPD (D-PPAC and C-PPAC) instruments

    Full text link
    BACKGROUND The Daily-PROactive and Clinical visit-PROactive Physical Activity (D-PPAC and C-PPAC) instruments in chronic obstructive pulmonary disease (COPD) combines questionnaire with activity monitor data to measure patients' experience of physical activity. Their amount, difficulty and total scores range from 0 (worst) to 100 (best) but require further psychometric evaluation. OBJECTIVE To test reliability, validity and responsiveness, and to define minimal important difference (MID), of the D-PPAC and C-PPAC instruments, in a large population of patients with stable COPD from diverse severities, settings and countries. METHODS We used data from seven randomised controlled trials to evaluate D-PPAC and C-PPAC internal consistency and construct validity by sex, age groups, COPD severity, country and language as well as responsiveness to interventions, ability to detect change and MID. RESULTS We included 1324 patients (mean (SD) age 66 (8) years, forced expiratory volume in 1 s 55 (17)% predicted). Scores covered almost the full range from 0 to 100, showed strong internal consistency after stratification and correlated as a priori hypothesised with dyspnoea, health-related quality of life and exercise capacity. Difficulty scores improved after pharmacological treatment and pulmonary rehabilitation, while amount scores improved after behavioural physical activity interventions. All scores were responsive to changes in self-reported physical activity experience (both worsening and improvement) and to the occurrence of COPD exacerbations during follow-up. The MID was estimated to 6 for amount and difficulty scores and 4 for total score. CONCLUSIONS The D-PPAC and C-PPAC instruments are reliable and valid across diverse COPD populations and responsive to pharmacological and non-pharmacological interventions and changes in clinically relevant variables

    Attitudes towards medication non-adherence in elderly kidney transplant patients: A Q methodology study

    Get PDF
    Background. Non-adherence to the post-transplant regime is a common problem in kidney transplant patients and may lead to rejection or even graft failure. This study investigated attitudes towards the post-transplant regime of immunosuppressive medication among the ever growing population of elderly kidney recipients.Methods. Q methodology was used to explore attitude profiles. Participants (> 65 years) were asked to rank-order opinion statements on issues associated with (non-)adherence. The rankings were subject to by-person factor analysis, and the resulting factors were interpreted and described as attitudes.Results. Twenty-six elderly renal transplant recipients participated in the study. All passed the Mini-Mental

    High-resolution, 3D radiative transfer modelling : IV. AGN-powered dust heating in NGC 1068

    Get PDF
    The star formation rate and the mass of interstellar medium (ISM) have a high predictive power for the future evolution of a galaxy. Nevertheless, deriving such properties is not straightforward. Dust emission, an important diagnostic of star formation and ISM mass throughout the Universe, can be powered by sources unrelated to ongoing star formation. In the framework of the DustPedia project we set out to disentangle the radiation of the ongoing star formation from that of the older stellar populations. This is done through detailed 3D radiative transfer simulations of face-on spiral galaxies. We take special care in modelling the morphological features present for each source of radiation. In this particular study, we focus on NGC 1068, which in addition contains an active galactic nucleus (AGN). The effect of diffuse dust heating by an AGN (beyond the torus) has so far only been investigated for quasars. This additional dust heating source further contaminates the broadband fluxes that are used by classic galaxy modelling tools to derive physical properties. We aim to fit a realistic model to the observations of NGC 1068 and quantify the contribution of the several dust-heating sources. Our model is able to reproduce the global spectral energy distribution of the galaxy. It matches the resolved optical and infrared images fairly well, but deviates in the UV and the submillimetre (submm). This is partly due to beam smearing effects, but also because the input dust distribution is not sufficiently peaked in the centre. We find that AGN contamination of the broadband fluxes has a strong dependency on wavelength. It peaks in the mid-infrared, drops in the far-infrared, and then rises again at submm wavelengths. We quantify the contribution of the dust-heating sources in each 3D dust cell and find a median value of 83% for the star formation component. The AGN contribution is measurable at the percentage level in the disc, but quickly increases in the inner few hundred parsecs, peaking above 90%. This is the first time the phenomenon of an AGN heating the diffuse dust beyond its torus is quantified in a nearby star-forming galaxy. NGC 1068 only contains a weak AGN, meaning this effect could be stronger in galaxies with a more luminous AGN. This could significantly impact the derived star formation rates and ISM masses for such systems

    Validity and responsiveness of the Daily- and Clinical visit-PROactive Physical Activity in COPD (D-PPAC and C-PPAC) instruments

    Get PDF
    Background: The Daily-PROactive and Clinical visit-PROactive Physical Activity (D-PPAC and C-PPAC) instruments in chronic obstructive pulmonary disease (COPD) combines questionnaire with activity monitor data to measure patients' experience of physical activity. Their amount, difficulty and total scores range from 0 (worst) to 100 (best) but require further psychometric evaluation. Objective: To test reliability, validity and responsiveness, and to define minimal important difference (MID), of the D-PPAC and C-PPAC instruments, in a large population of patients with stable COPD from diverse severities, settings and countries. Methods: We used data from seven randomised controlled trials to evaluate D-PPAC and C-PPAC internal consistency and construct validity by sex, age groups, COPD severity, country and language as well as responsiveness to interventions, ability to detect change and MID. Results: We included 1324 patients (mean (SD) age 66 (8) years, forced expiratory volume in 1 s 55 (17)% predicted). Scores covered almost the full range from 0 to 100, showed strong internal consistency after stratification and correlated as a priori hypothesised with dyspnoea, health-related quality of life and exercise capacity. Difficulty scores improved after pharmacological treatment and pulmonary rehabilitation, while amount scores improved after behavioural physical activity interventions. All scores were responsive to changes in self-reported physical activity experience (both worsening and improvement) and to the occurrence of COPD exacerbations during follow-up. The MID was estimated to 6 for amount and difficulty scores and 4 for total score. Conclusions: The D-PPAC and C-PPAC instruments are reliable and valid across diverse COPD populations and responsive to pharmacological and non-pharmacological interventions and changes in clinically relevant variables

    Validity and responsiveness of the Daily- and Clinical visit-PROactive Physical Activity in COPD (D-PPAC and C-PPAC) instruments

    Get PDF
    BACKGROUND: The Daily-PROactive and Clinical visit-PROactive Physical Activity (D-PPAC and C-PPAC) instruments in chronic obstructive pulmonary disease (COPD) combines questionnaire with activity monitor data to measure patients' experience of physical activity. Their amount, difficulty and total scores range from 0 (worst) to 100 (best) but require further psychometric evaluation. OBJECTIVE: To test reliability, validity and responsiveness, and to define minimal important difference (MID), of the D-PPAC and C-PPAC instruments, in a large population of patients with stable COPD from diverse severities, settings and countries. METHODS: We used data from seven randomised controlled trials to evaluate D-PPAC and C-PPAC internal consistency and construct validity by sex, age groups, COPD severity, country and language as well as responsiveness to interventions, ability to detect change and MID. RESULTS: We included 1324 patients (mean (SD) age 66 (8) years, forced expiratory volume in 1 s 55 (17)% predicted). Scores covered almost the full range from 0 to 100, showed strong internal consistency after stratification and correlated as a priori hypothesised with dyspnoea, health-related quality of life and exercise capacity. Difficulty scores improved after pharmacological treatment and pulmonary rehabilitation, while amount scores improved after behavioural physical activity interventions. All scores were responsive to changes in self-reported physical activity experience (both worsening and improvement) and to the occurrence of COPD exacerbations during follow-up. The MID was estimated to 6 for amount and difficulty scores and 4 for total score. CONCLUSIONS: The D-PPAC and C-PPAC instruments are reliable and valid across diverse COPD populations and responsive to pharmacological and non-pharmacological interventions and changes in clinically relevant variables
    corecore