18 research outputs found
Optoelectronic sensor of longitudinal and angular displacements
In the sensor a triangulation method of displacement measurement has been used. A method of sensor calibration using interferometric distance measurements has been elaborated. Linearity and resolution investigations have been performed for different parameter sets of sensor transmitting-receiving head. An accuracy of displacement measurements depends on parameters of a beam illuminating a surface being displaced, parameters of a position sensitive detector and on a signal-to-noise ratio of a signal analog processing block. Results of investigations of uncertainties of lathe slide shifts are also presented
The biochemical processes and molecular mechanisms of aluminium toxicity
Na podstawie literatury omówiono metabolizm glinu, lokalizację tego pierwiastka w komórkach i tkankach ludzkich i zwierzęcych oraz zachowanie jonów glinu na poziomie struktur komórkowych.On the basis of a literature metabolism of aluminium, intracellular localization and concentration of A13+ in the human and animal tissues, effect of aluminium on cellular structures were discussed
Content of heavy metals in Polish mineral and spring waters
Celem badań było oznaczenie metali ciężkich w najpopularniejszych wodach źródlanych
i mineralnych dostępnych na rynku polskim.
Oznaczano zawartość Cd, Pb, Al, Ni, Fe, Cr i Mn, stosując metodę spektrometrii absorpcji
atomowej (AAS).
Wykazano, że oprócz jednego przypadku (tab. 4), we wszystkich badanych wodach nie zostały przekroczone wartości metali ciężkich, określone jako dopuszczalne przez Ministerstwo
Zdrowia w Zarządzeniu z dn. 04.09.2000 r.The aim of this study was to assay the contents of heavy metals in the most popular
Polish spring and mineral waters available on markets.
For determination of the contents of Cd, Pb, Al, Ni, Fe, Cr and Mn atomic absorption
spectrometry (AAS) method was used.
It results from the research that the concentrations of heavy metals in all tested waters
(with one exception – Table 4) did not exceed the acceptable level as defined by the
Ministry of Health ordinance dated Oct. 4, 2000
Zawartosc manganu w surowicy krwi, erytrocytach i wlosach mezczyzn - pracownikach lotniska
Manganese is a component and cofactor for many important enzymes. In blood Mn is complexed to transferrin, and it quickly passes through the body to be extracted mainly in the bile and urine. Almost all Mn pool in blood is located in erythrocytes. Content of manganese in serum, erythrocytes, and hair of 26 men, workers of an airport, was determined. The control group consisted of administrative workers and the test group was composed of airplane servicemen. Hair samples of 0.5 g and 3-4 cm in length measured from the scalp were taken from some places on a head, washed with a detergent solution, rinsed with deionized water, acetone, and dried. Samples of blood were spun. All the samples were mineralized in a mixture of spectrally clean acids HNO3 and HClO4. Concentration of Mn was analyzed by electrothermal atomic absorption spectrometry GFAAS. The concentrations of Mn in the samples of erythrocytes were statistical significantly higher in the test group. In samples of hair, Mn concentrations were comparable between both groups of men. The coefficients of correlation between Mn concentrations in serum and hair, erythrocytes and hair, and between serum and erythrocytes did not imply significant correlations between Mn concentration in the analyzed clinical samples. In contrast, in the erythrocytes of men exposed on aviation fuel the content of Mn was significantly higher.Mangan jest kofaktorem i składnikiem wielu enzymów. We krwi jest związany głównie z transferyną, szybko ulega dystrybucji i szybko jest wydalany z organizmu, przede wszystkim z żółcią. Niewielkie ilości tego pierwiastka są wydalane w moczu. Prawie cała pula Mn we krwi jest zlokalizowana w erytrocytach. W pracy oznaczono zawartość manganu w surowicy, erytrocytach i włosach 26 mężczyzn będących pracownikami lotniska. Grupę kontrolną stanowili pracownicy administracyjni, natomiast grupę badaną - mężczyźni obsługujący samoloty. Włosy pobrano z kilku punktów głowy, w ilości ok. 0.5 g i długości 3-4 cm, licząc od skóry. Próbki włosów umyto w roztworze detergentu, wodzie dejonizowanej i acetonie, a następnie wysuszono. Próbki krwi odwirowano i oddzielono masę erytrocytarną od surowicy. Tak przygotowane próbki mineralizowano w mieszaninie spektralnie czystych kwasów HNO3 i HClO4. Zawartość manganu oznaczono metodą spektrometrii absorpcji atomowej z atomizacją w piecu grafitowym GFAAS. Oznaczona zawartość Mn w badanych próbkach erytrocytów była statystycznie istotnie wyższa w grupie kontrolnej. W próbkach włosów zawartość Mn była porównywalna w obu grupach mężczyzn. Wyznaczone współczynniki korelacji między zawartością Mn w surowicy i we włosach, erytrocytach i we włosach oraz w surowicy i erytrocytach nie wskazują na występowanie istotnych zależności między zawartością Mn w badanych próbkach klinicznych. W badaniach, zarówno w surowicy, erytrocytach i włosach mężczyzn z grupy kontrolnej, jak i w badanej, nie stwierdzono, aby w znaczący sposób kumulował się mangan. Jednak w erytrocytach pracowników obsługujących lotnisko ilość Mn była znamiennie wyższa
Analiza porownawcza stezen pierwiastkow sladowych w plynach dializacyjnych przed i za dializatorem
Disturbances of mineral metabolism are one of the many complications observed in patients
with renal failure. Fluids used in dialysotherapy may introduce elements to a patient’s
body. On the other hand, some trace elements may be removed. Dialysis fluids contain
chlorides of calcium (Ca), magnesium (Mg), sodium (Na), and potassium (K), but they
may also be contaminated by toxic metals. In the first part of our work the amounts of Mg,
Ca, zinc (Zn), and iron (Fe) were determined in samples of hemodialysis fluids just before
and after a dialyzer. The concentration of copper (Cu), aluminium (Al), lead (Pb), cadmium
(Cd), and chromium (Cr) were measured by the atomic absorption spectrometry method
(AAS) in a graphite furnace (GFAAS) in the same dialysates. The average concentration
of Cu in dialysis fluids before and after dialyzer was 13.51 and 10.51 μg L-1 respectively,
Al – 8.72 and 7.88 μg L-1, Pb – 24.03 and 22.81 μg L-1, Cd – 1.09 and 1.07 μg L-1, Cr – 5.91
and 6.28 μg L-1. Except for Cr (p < 0.05), the comparison of concentrations of all the measured
elements before and after haemodialysis did not show any significant differences.
Positive significant correlations between the element concentration before and after a dialyzer
were found for Al (r = 0.33030 and Cd (r = 0.7496). In the samples of dialysis fluids
of patients who had been dialyzed for less than one year, a negative balance of elements
was found, except Pb. The balance was positive in patients who had been dialyzed for more
than a year. Our findings also show statistically significant negative correlation between
duration of dialysis treatments and Al concentration. Statistically, the examined dialysis fluids
seem to be safe for dialyzed patients. However, individual data show that it is important
to control elemental levels in dialyzates used for many years to prevent some complications
in these patients.Zaburzenia w gospodarce mineralnej to jedno z wielu powikłań obserwowanych u pacjentów
ze schyłkową niewydolnością nerek. Płyny stosowane w dializoterapii mogą do organizmu
dostarczać pierwiastki, ale mogą je także z niego usuwać. W składzie płynów dializacyjnych
znajdują się chlorki Ca, Mg Na i K. Mogą one także zawierać inne metale będące
ich zanieczyszczeniami. W pierwszym etapie pracy oznaczono stężenie Ca, Mg, Zn i Fe
w 38 próbkach płynów dializacyjnych przed i za dializatorem. Stężenie tych pierwiastków
nie zmieniło się w sposób istotny statystycznie, ale stężenie Zn było o ok. 7% wyższe w płynie
po zabiegu, a w kilku z nich stwierdzono podwyższone stężenie Fe. Celem pracy było
oznaczenie w tych samych dializatach stężeń pierwiastków śladowych istotnie wpływających na funkcje organizmu. Porównawcze oznaczenia stężenia miedzi (Cu), glinu (Al), ołowiu
(Pb), kadmu (Cd) i chromu (Cr) wykonano metodą spektrometrii absorpcji atomowej
z atomizacją w piecu grafitowym (GFAAS). Zastosowane procedury analityczne zapewniają
dobrą czułość i precyzję metody. Średnie stężenie Cu w płynach przed i za dializatorem
wynosiło 13,51 i 10,51 μg L-1, Al – 8,27 i 7,88 μg L-1, Pb – 24,03 i 22,81 μg L-1, Cd – 1,09
i 1,07 μg L-1, Cr – 5,91 i 6,28 μg L-1. Z wyjątkiem Cr (p<0,05), stężenie pierwiastków w płynach
przed i za dializatorem nie różniło w sposób statystycznie istotny. Dodatnie istotne
korelacje między zawartością pierwiastków przed i za dializatorem wyznaczono dla Al
(r = 0,3303) i Cd (r = 0,7496). W próbkach płynów dializacyjnych pacjentów dializowanych
w czasie krótszym niż rok stwierdzono, z wyjątkiem Pb, ujemny bilans pierwiastków, a powyżej roku – dodatni. Stwierdzono ujemną istotną korelację między czasem trwania dializoterapii
a stężeniem Al.
Badane płyny dializacyjne, uwzględniając ocenę statystyczną, nie zwiększają ekspozycji
pacjentów dializowanych na oznaczane metale ciężkie. Z analizy danych indywidualnych
wynika jednak, że płyny te, ze względu na systematyczne stosowanie w ciągu wielu lat,
mogą wywierać wpływ na status mineralny pacjenta, i dlatego też pod tym kątem powinny
być kontrolowane
Badania nad zawartoscia niklu we wlosach ludzkich
Effect of nickel (Ni) on human organism is still evaluated, although there are few
research papers dedicated to this problem. The participation of Ni in carcinogenesis and
allergic reactions is considered. Nickel is absorbed through the alimentary tract, lungs and
skin. Concentration of Ni in blood and urine is low (about 1 μg L-1). More nickel has been
determined in tissues such as liver, lungs and osseous tissue. The aim of this work was to
assess the Ni level in human hair (n = 220, 110 women and 110 men) and correlations
between Ni and other elements i.e. calcium (Ca), magnesium (Mg), zinc (Zn), iron (Fe),
lead (Pb), and cadmium (Cd). Hair washed with acetone and redistilled water was mineralized
in mixture of HNO3 and HClO4 acids. Content of the elements was determined by
the atomic absorption spectrometry method AAS. Concentrations of Ca, Mg, Zn, Cu, and
Fe was measured by the flame technique (FAAS), while concentration of Pb, Cd and Ni
was analyzed by the electrothermal atomic absorption spectrometry in a graphite furnace
(GFAAS). The data were the subject of statistical analysis. The mean Ni concentration in
the hair samples was 0.24 μg g-1 (median 0.17 μg g-1, range 0.01-1.77 μg g-1). Slightly
more Ni was found in hair of women (0.25 μg g-1) than of men (0.22 μg g-1). Statistically
higher concentrations of Ni were noticed in hair of men > 20 years than in younger men
(p<0.05). Statistically significant positive correlations (for Zn, negative correlation) were established
between Ni and Cd, Pb, and Cu concentration. Hair is available easily and noninvasively
for tests and owing to a higher Ni level in hair than in physiological fluids, such
tests help reduce analytical error. Therefore, hair is a very suitable material for monitoring
elements in the human body.Oddziaływanie niklu (Ni) na organizm człowieka nadal jest przedmiotem badań, jednak
liczba opublikowanych prac poświęconych tej tematyce jest niewielka. Rozpatrywany
jest udział tego pierwiastka w procesie kancerogenezy oraz jako czynnika wywołującego
alergię. Główne drogi wchłaniania Ni to przewód pokarmowy, płuca i skóra. Stężenie tego
pierwiastka we krwi i moczu jest niskie i wynosi ok. 1 μg L-1. Większe jego ilości oznaczono
w tkankach (wątrobie, płucach, tkance kostnej). Celem pracy była ocena zawartości Ni
we włosach (n=220, 110 kobiet i 110 mężczyzn) oraz korelacji między jego stężeniem a stężeniem innych pierwiastków: wapniem (Ca), magnezem (Mg), cynkiem (Zn), żelazem (Fe),
ołowiem (Pb) i kadmem (Cd). Włosy umyte w acetonie i wodzie mineralizowano na mokro
w mieszaninie kwasów HNO3 i HClO4. Zawartość pierwiastków oznaczano metodą spektrometrii
absorpcji atomowej (AAS). Stężenie Ca, Mg, Zn, Cu i Fe wykonano techniką płomieniową (FAAS), natomiast Pb, Cd i Ni techniką bezpłomieniową w piecu grafitowym
(GFAAS). Otrzymane dane poddano analizie statystycznej. Zawartość pierwiastków podano
w zależności od płci i wieku. Średnia zawartość Ni w badanych próbkach włosów wynosiła
0,24 μg g-1 (mediana 0,17 μg g-1, rozrzut 0,01-1,77 μg g-1), nieco więcej tego pierwiastka
stwierdzono we włosach kobiet (0,25 μg g-1) niż u mężczyzn (0,22 μg g-1) i statystycznie
więcej we włosach mężczyzn powyżej 20 lat w porównaniu z grupą wiekową poniżej 20.
roku życia (p<0,05). Istotne statystycznie dodatnie korelacje (z wyjątkiem Zn) wyznaczono
między zawartością Ni oraz Cd, Pb i Cu. Włosy są tkanką dostępną w sposób łatwy i nieinwazyjny,
a ze względu na znacznie wyższą zawartość Ni w porównaniu z płynami ustrojowymi
stanowił dobry materiał badań, co umożliwia zmniejszenie błędów pomiarowych podczas
analizy