160 research outputs found

    Measurements of wavelength dependent scattering and backscattering coefficients by low-coherence spectroscopy

    Get PDF
    Quantitative measurements of scattering properties are invaluable for optical techniques in medicine. However, noninvasive, quantitative measurements of scattering properties over a large wavelength range remain challenging. We introduce low-coherence spectroscopy as a noninvasive method to locally and simultaneously measure scattering μs and backscattering μb coefficients from 480 to 700 nm with 8 nm spectral resolution. The method is tested on media with varying scattering properties (μs = 1 to 34 mm−1 and μb = 2.10−6 to 2.10−3 mm−1), containing different sized polystyrene spheres. The results are in excellent agreement with Mie theor

    Ongoing outbreaks of hepatitis A among men who have sex with men (MSM), Berlin, November 2016 to January 2017 – linked to other German cities and European countries

    Get PDF
    Since 14 November 2016, 38 cases of hepatitis A have been notified in Berlin; of these, 37 were male and 30 reported to have sex with men (MSM). Median age of MSM cases is 31 years (range: 24–52 years). Phylogenetic analysis revealed three distinct sequences, linking cases in Berlin to those in other German cities and to clusters recognised in other European countries in 2016

    Quantitative measurements of absorption spectra in scattering media by low-coherence spectroscopy

    Get PDF
    Low-coherence spectroscopy (LCS) is a spectroscopic method that allows for quantitative and localized assessment of absorption spectra by combining reflection spectroscopy with low-coherence interferometry. We describe absorption coefficient (µa) measurements by LCS in tissue simulating phantoms with varying scattering and absorbing properties. We used LCS in the 455–680 nm wavelength range with a spectral resolution of 8 nmto obtain µa spectra with ±0.5 mm−1 accuracy. We conclude that LCS is a promising technique for the in vivo determination of tissue chromophore concentrations

    Multidiameter single-fiber reflectance spectroscopy of heavily pigmented skin:modeling the inhomogeneous distribution of melanin

    Get PDF
    When analyzing multidiameter single-fiber reflectance (MDSFR) spectra, the inhomogeneous distribution of melanin pigments in skin tissue is usually not accounted for. Especially in heavily pigmented skins, this can result in bad fits and biased estimation of tissue optical properties. A model is introduced to account for the inhomogeneous distribution of melanin pigments in skin tissue. In vivo visible MDSFR measurements were performed on heavily pigmented skin of type IV to VI. Skin tissue optical properties and related physiological properties were extracted from the measured spectra using the introduced model. The absorption of melanin pigments described by the introduced model demonstrates a good correlation with the co-localized measurement of the well-known melanin index. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License

    Simple and robust calibration procedure for k-linearization and dispersion compensation in optical coherence tomography

    Get PDF
    In Fourier-domain optical coherence tomography (FD-OCT), proper signal sampling and dispersion compensation are essential steps to achieve optimal axial resolution. These calibration steps can be performed through numerical signal processing, but require calibration information about the system that may require lengthy and complex measurement protocols. We report a highly robust calibration procedure that can simultaneously determine correction vectors for nonlinear wavenumber sampling and dispersion compensation. The proposed method requires only two simple mirror measurements and no prior knowledge about the system's illumination source or detection scheme. This method applies to both spectral domain and swept-source OCT systems. Furthermore, it may be implemented as a low-cost fail-safe to validate the proper function of calibration hardware such as k-clocks. We demonstrate the method's simple implementation, effectiveness, and robustness on both types of OCT systems

    Resurgence of an international hepatitis A outbreak linked to imported frozen strawberries, Germany, 2018 to 2020

    Get PDF
    Following outbreaks linked to frozen strawberries in Sweden and Austria in 2018, 65 cases linked to the same hepatitis A virus strain were detected in Germany between October 2018 and January 2020, presenting in two waves. Two case-control studies and a comparison of cases' consumption frequencies with purchase data from a large consumer panel provided strong evidence for frozen strawberry cake as the main vehicle of transmission. Of 46 cases interviewed, 27 reported consuming frozen strawberry cake and 25 of these identified cake(s) from brand A spontaneously or in product picture-assisted recall. Trace back investigations revealed that the Polish producer involved in the previous outbreaks in Sweden and Austria had received frozen strawberries from Egypt via a wholesaler that also delivered frozen strawberries to manufacturer of brand A. Phylogenetic analyses linked the outbreak strain to similar strains formerly isolated from sewage, stool and strawberries in Egypt. Complete trace back and timely recall of products with strong evidence of contamination is important to control an outbreak and prevent later resurgence, particularly for food items with a long shelf life. Continued molecular surveillance of hepatitis A is needed to identify outbreaks and monitor the success of food safety interventions
    corecore