310 research outputs found

    Elastic Instabilities of Polymer Solutions in Cross-Channel Flow

    Get PDF
    When polymer molecules pass near the hyperbolic point of a microchannel cross flow, they are strongly stretched. As the strain rate is varied at low Reynolds number ( \u3c 10-2), tracer and particle-tracking experiments show that molecular stretching produces two flow instabilities: one in which the velocity field becomes strongly asymmetric, and a second in which it fluctuates nonperiodically in time. The flow is strongly perturbed even far from the region of instability, and this phenomenon can be used to produce mixing

    Environmental regulation of the neural epigenome

    Get PDF
    AbstractParental effects are a major source of phenotypic plasticity. Moreover, there is evidence from studies with a wide range of species that the relevant parental signals are influenced by the quality of the parental environment. The link between the quality of the environment and the nature of the parental signal is consistent with the idea that parental effects, whether direct or indirect, might serve to influence the phenotype of the offspring in a manner that is consistent with the prevailing environmental demands. In this review we explore recent studies from the field of ‘environmental epigenetics’ that suggest that (1) DNA methylation states are far more variable than once thought and that, at least within specific regions of the genome, there is evidence for both demethylation and remethylation in post-mitotic cells and (2) that such remodeling of DNA methylation can occur in response to environmentally-driven, intracellular signaling pathways. Thus, studies of variation in mother–offspring interactions in rodents suggest that parental signals operate during pre- and/or post-natal life to influence the DNA methylation state at specific regions of the genome leading to sustained changes in gene expression and function. We suggest that DNA methylation is a candidate mechanism for parental effects on phenotypic variation

    Studies on the Ultrastructure of Fibrin Lacking Fibrinopeptide B (ÎČ-Fibrin)

    Get PDF
    Release of fibrinopeptide B from fibrinogen by copperhead venom procoagulant enzyme results in a form of fibrin (beta-fibrin) with weaker self-aggregation characteristics than the normal product (alpha beta-fibrin) produced by release of fibrinopeptides A (FPA) and B (FPB) by thrombin. We investigated the ultrastructure of these two types of fibrin as well as that of beta-fibrin prepared from fibrinogen Metz (A alpha 16 Arg----Cys), a homozygous dysfibrinogenemic mutant that does not release FPA. At 14 degrees C and physiologic solvent conditions (0.15 mol/L of NaCl, 0.015 mol/L of Tris buffer pH 7.4), the turbidity (350 nm) of rapidly polymerizing alpha beta-fibrin (thrombin 1 to 2 U/mL) plateaued in less than 6 min and formed a “coarse” matrix consisting of anastomosing fiber bundles (mean diameter 92 nm). More slowly polymerizing alpha beta-fibrin (thrombin 0.01 and 0.001 U/mL) surpassed this turbidity after greater than or equal to 60 minutes and concomitantly developed a network of thicker fiber bundles (mean diameters 118 and 186 nm, respectively). Such matrices also contained networks of highly branched, twisting, “fine” fibrils (fiber diameters 7 to 30 nm) that are usually characteristic of matrices formed at high ionic strength and pH. Slowly polymerizing beta-fibrin, like slowly polymerizing alpha beta-fibrin, displayed considerable quantities of fine matrix in addition to an underlying thick cable network (mean fiber diameter 135 nm), whereas rapidly polymerizing beta-fibrin monomer was comprised almost exclusively of wide, poorly anastomosed, striated cables (mean diameter 212 nm). Metz beta-fibrin clots were more fragile than those of normal beta-fibrin and were comprised almost entirely of a fine network. Metz fibrin could be induced, however, to form thick fiber bundles (mean diameter 76 nm) in the presence of albumin at a concentration (500 mumol/L) in the physiologic range and resembled a Metz plasma fibrin clot in that regard. The diminished capacity of Metz beta-fibrin to form thick fiber bundles may be due to impaired use or occupancy of a polymerization site exposed by FPB release. Our results indicate that twisting fibrils are an inherent structural feature of all forms of assembling fibrin, and suggest that mature beta-fibrin or alpha beta-fibrin clots develop from networks of thin fibrils that have the ability to coalesce to form thicker fiber bundles

    Genotypes and haplotypes in the insulin-like growth factors, their receptors and binding proteins in relation to plasma metabolic levels and mammographic density

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Increased mammographic density is one of the strongest independent risk factors for breast cancer. It is believed that one third of breast cancers are derived from breasts with more than 50% density. Mammographic density is affected by age, BMI, parity, and genetic predisposition. It is also greatly influenced by hormonal and growth factor changes in a woman's life cycle, spanning from puberty through adult to menopause. Genetic variations in genes coding for hormones and growth factors involved in development of the breast are therefore of great interest. The associations between genetic polymorphisms in genes from the IGF pathway on mammographic density and circulating levels of IGF1, its binding protein IGFBP3, and their ratio in postmenopausal women are reported here.</p> <p>Methods</p> <p>Samples from 964 postmenopausal Norwegian women aged 55-71 years were collected as a part of the Tromsþ Mammography and Breast Cancer Study. All samples were genotyped for 25 SNPs in IGF1, IGF2, IGF1R, IGF2R, IGFALS and IGFBP3 using Taqman (ABI). The main statistical analyses were conducted with the PROC HAPLOTYPE procedure within SAS/GENETICSℱ (SAS 9.1.3).</p> <p>Results</p> <p>The haplotype analysis revealed six haploblocks within the studied genes. Of those, four had significant associations with circulating levels of IGF1 or IGFBP3 and/or mammographic density. One haplotype variant in the IGF1 gene was found to be associated with mammographic density. Within the IGF2 gene one haplotype variant was associated with levels of both IGF1 and IGFBP3. Two haplotype variants in the IGF2R were associated with the level of IGF1. Both variants of the IGFBP3 haplotype were associated with the IGFBP3 level and indicate regulation in cis.</p> <p>Conclusion</p> <p>Polymorphisms within the IGF1 gene and related genes were associated with plasma levels of IGF1, IGFBP3 and mammographic density in this study of postmenopausal women.</p

    Exploring Advanced Technology Gas Turbine Engine Design and Performance for the Large Civil Tiltrotor (LCTR)

    Get PDF
    A Large Civil Tiltrotor (LCTR) conceptual design was developed as part of the NASA Heavy Lift Rotorcraft Systems Investigation in order to establish a consistent basis for evaluating the benefits of advanced technology for large tiltrotors. The concept has since evolved into the second-generation LCTR2, designed to carry 90 passengers for 1,000 nautical miles at 300 knots, with vertical takeoff and landing capability. This paper explores gas turbine component performance and cycle parameters to quantify performance gains possible for additional improvements in component and material performance beyond those identified in previous LCTR2 propulsion studies and to identify additional research areas. The vehicle-level characteristics from this advanced technology generation 2 propulsion architecture will help set performance levels as additional propulsion and power systems are conceived to meet ever-increasing requirements for mobility and comfort, while reducing energy use, cost, noise and emissions. The Large Civil Tiltrotor vehicle and mission will be discussed as a starting point for this effort. A few, relevant engine and component technology studies, including previous LCTR2 engine study results will be summarized to help orient the reader on gas turbine engine architecture, performance and limitations. Study assumptions and methodology used to explore engine design and performance, as well as assess vehicle sizing and mission performance will then be discussed. Individual performance for present and advanced engines, as well as engine performance effects on overall vehicle size and mission fuel usage, will be given. All results will be summarized to facilitate understanding the importance and interaction of various component and system performance on overall vehicle characteristics

    Dietary calcium and vitamin D intakes in childhood and throughout adulthood and mammographic density in a British birth cohort

    Get PDF
    We examined the role of dietary calcium and vitamin D intakes in childhood and throughout adulthood in relation to mammographic density using data from a nationally representative cohort of 1161 women followed up since their birth in 1946. Dietary intakes at the age of 4 years were determined by 24-h recalls and at the ages of 36, 43 and 53 years by 5-day food records. After adjusting for known risk factors and confounders, no evidence of a relationship between dietary calcium or vitamin D intakes and mammographic density approximately at the age of 50 years was found, except for a cross-sectional relationship between dietary calcium intake at the age of 53 years and breast density in women who were post-menopausal at the time of mammography, with those in the top fifth of the distribution of calcium intake having a 0.53 s.d. lower percent breast density than those in the lowest fifth (P-value <0.01 for linear trend)

    Body mass index and circulating oestrone sulphate in women treated with adjuvant letrozole

    Get PDF
    Background: Obesity is an independent adverse prognostic factor in early breast cancer patients, but it is still controversial whether obesity may affect adjuvant endocrine therapy efficacy. The aim of our study (ancillary to the two clinical trials Gruppo Italiano Mammella (GIM)4 and GIM5) was to investigate whether the circulating oestrogen levels during treatment with the aromatase inhibitor letrozole are related to body mass index (BMI) in postmenopausal women with breast cancer. Methods: Plasma concentration of oestrone sulphate (ES) was evaluated by radioimmunoassay in 370 patients. Plasma samples were obtained after at least 6 weeks of letrozole therapy (steady-state time). Patients were divided into four groups according to BMI. Differences among the geometric means (by ANOVA and ANCOVA) and correlation (by Spearman's rho) between the ES levels and BMI were assessed. Results: Picomolar geometric mean values (95% confidence interval, n=patients) of circulating ES during letrozole were 58.6 (51.0-67.2, n=150) when BMI was <25.0 kg m-2; 65.6 (57.8-74.6, n=154) when 25.0-29.9 kg m-2; 59.3 (47.1-74.6, n=50) when 30.0-34.9 kg m -2; and 43.3 (23.0-81.7, n=16) when 6535.0 kg m-2. No statistically significant difference in terms of ES levels among groups and no correlation with BMI were observed. Conclusions: Body mass index does not seem to affect circulating oestrogen levels in letrozole-treated patient

    Dietary intake and breast density in high-risk women: a cross-sectional study

    Get PDF
    Background Women with a family history of breast cancer may be at higher risk for breast cancer, but few previous studies evaluating diet and breast cancer have focused on such women. The objective of the present study was to determine whether diet, a modifiable risk factor, is related to breast density among women at high genetic risk for breast cancer. Methods Women with at least one first-degree or second-degree relative with breast cancer or ovarian cancer participating in the Fox Chase Cancer Center Family Risk Assessment Program completed health history and food frequency questionnaires and received standard screening mammograms. Cranial–caudal mammographic images were classified into the four Breast Imaging Reporting and Data System categories ranging from \u27entirely fatty\u27 to \u27extremely dense\u27. Logistic regression analysis using proportional odds models for polychotomous outcomes provided estimates of odds ratios for having a higher category versus a lower category of breast density. Results Among 157 high-risk women, breast density was inversely associated with vitamin D intake (odds ratio for third tertile versus first tertile, 0.5; 95% confidence interval, 0.2–1.0). In contrast, intakes above the median level for protein (odds ratio, 3.0; 95% confidence interval, 1.3–6.9) and above the median level for animal protein (odds ratio, 4.3; 95% confidence interval, 1.8–10.3) were associated with higher breast density, but only among women whose family history did not reflect a known familial cancer syndrome or a breast cancer predisposition gene. Conclusion For women with a strong family history that was not associated with known cancer syndromes, dietary factors may be associated with breast density, a strong predictor of breast cancer risk. Since women with strong family history are often very motivated to change their lifestyle habits, further studies are needed to confirm whether changes in diet will change the breast density and the subsequent onset of breast cancer in these women
    • 

    corecore