51 research outputs found

    Determination of benazepril HCl and hydrochlorothiazide in pharmaceutical preparations using UV-visible spectrophotometry and genetic multivariate calibration method

    Get PDF
    Simultaneous determination of binary mixtures of benazepril and hydrochlorothiazide in pharmaceutical tablets using UV-visible spectrophotometry, classical least squares (CLS) and three genetic algorithms (GA) based multivariate calibration methods was demonstrated. The three genetic multivariate calibration methods are Genetic Classical Least Squares (GCLS), Genetic Inverse Least Squares (GILS) and Genetic Regression (GR). The sample data set contains the UV- spectra of 28 synthetic mixtures of benazepril (12∼36 μg/mL) and hydrochlorothiazide (10∼22 μg/mL) and 16 tablets containing both compounds. The spectra cover the range from 210 to 360 nm in 0.1 mn intervals. Several calibration models were built with the four methods. The root mean square error of calibration (RMSEC) and validation (RMSEV) for the synthetic data were in the range of 0.19 and 0.34 μg/mL for all the genetic algorithm based methods. The root mean square error of Prediction (RMSEP) values for the tablets were in the range of 0.04∼0.20 mg/tablets. A comparison of genetic algorithm selected wavelengths for each component was also included

    Application of Haar and Mexican hat wavelets to double divisor-ratio spectra for the multicomponent determination of ascorbic acid, acetylsalicylic acid and paracetamol in effervescent tablets

    Full text link
    Simultaneous determination of ascorbic acid (AA), acetylsalicylic acid (ASP) and paracetamol (PAR) in their synthetic mixtures and effervescent tablets were performed by Haar and Mexican continuous wavelet transforms (HAAR-CWT and MEXH-CWT, respectively) together with double divisor technique. The signal processing methods are based on the application of HAAR-CWT and MEXH-CWT to the double divisor-ratio spectra (DDRS). These spectra were obtained by dividing the absorption spectra of pure compound and its ternary mixtures by a double-divisor or standard spectrum corresponding to a mixture of two compounds in ternary mixture. A combined use of HAAR-CWT and MEXH-CWT with double divisor-ratio spectra (DDRS) was denoted by DDRS-HAAR CWT and DDRS-MEXH CWT. To check the ability or applicability of the developed DDRS-CWT methods, the double divisor-ratio spectra-derivative spectrophotometric (DDRS-DS) method, as a comparison method, was applied to the above mentioned samples containing AA, ASP and PAR and satisfactory results were obtained

    Analysis of UV spectral bands using multidimensional scaling

    Get PDF
    This study describes the change of the ultraviolet spectral bands starting from 0.1 to 5.0 nm slit width in the spectral range of 200–400 nm. The analysis of the spectral bands is carried out by using the multidimensional scaling (MDS) approach to reach the latent spectral background. This approach indicates that 0.1 nm slit width gives higher-order noise together with better spectral details. Thus, 5.0 nm slit width possesses the higher peak amplitude and lower-order noise together with poor spectral details. In the above-mentioned conditions, the main problem is to find the relationship between the spectral band properties and the slit width. For this aim, the MDS tool is to used recognize the hidden information of the ultraviolet spectra of sildenafil citrate by using a Shimadzu UV–VIS 2550, which is in the world the best double monochromator instrument. In this study, the proposed mathematical approach gives the rich findings for the efficient use of the spectrophotometer in the qualitative and quantitative studies

    Analysis of UV spectral bands using multidimensional scaling

    Get PDF
    This study describes the change of the ultraviolet spectral bands starting from 0.1 to 5.0 nm slit width in the spectral range of 200–400 nm. The analysis of the spectral bands is carried out by using the multidimensional scaling (MDS) approach to reach the latent spectral background. This approach indicates that 0.1 nm slit width gives higher-order noise together with better spectral details. Thus, 5.0 nm slit width possesses the higher peak amplitude and lower-order noise together with poor spectral details. In the above-mentioned conditions, the main problem is to find the relationship between the spectral band properties and the slit width. For this aim, the MDS tool is to used recognize the hidden information of the ultraviolet spectra of sildenafil citrate by using a ShimadzuUV–VIS 2550, which is in theworld the best double monochromator instrument. In this study, the proposed mathematical approach gives the rich findings for the efficient use of the spectrophotometer in the qualitative and quantitative studies

    Wavelet Transform-Based UV Spectroscopy for Pharmaceutical Analysis

    Get PDF
    In research and development laboratories, chemical or pharmaceutical analysis has been carried out by evaluating sample signals obtained from instruments. However, the qualitative and quantitative determination based on raw signals may not be always possible due to sample complexity. In such cases, there is a need for powerful signal processing methodologies that can effectively process raw signals to get correct results. Wavelet transform is one of the most indispensable and popular signal processing methods currently used for noise removal, background correction, differentiation, data smoothing and filtering, data compression and separation of overlapping signals etc. This review article describes the theoretical aspects of wavelet transform (i.e., discrete, continuous and fractional) and its characteristic applications in UV spectroscopic analysis of pharmaceuticals

    Application of continuous wavelet transform to the analysis of the modulus of the fractional Fourier transform bands for resolving two component mixture

    Get PDF
    In this paper, the fractional Fourier transform (FrFT) is applied to the spectral bands of two component mixture containing oxfendazole and oxyclozanide to provide the multicomponent quantitative prediction of the related substances. With this aim in mind, the modulus of FrFT spectral bands are processed by the continuous Mexican Hat family of wavelets, being denoted by MEXH-CWT-MOFrFT. Four modulus sets are obtained for the parameter a of the FrFT going from 0.6 up to 0.9 in order to compare their effects upon the spectral and quantitative resolutions. Four linear regression plots for each substance were obtained by measuring the MEXH-CWT-MOFrFT amplitudes in the application of the MEXH family to the modulus of the FrFT. This new combined powerful tool is validated by analyzing the artificial samples of the related drugs, and it is applied to the quality control of the commercial veterinary samples

    Continuous wavelet transform methods for the simultaneous determinations and dissolution profiles of valsartan and hydrochlorothiazide in tablets

    Get PDF
    Continuous wavelet transform (CWT) was proposed for the simultaneous determination and dissolution profiles of valsartan (VAL) and hydrochlorothiazide (HCT) in tablets, without the use of a chemical separation procedure. The CWT approach was applied to the original UV spectra and their ratio spectra in the optimal wavelength ranges. After testing several wavelet families, Mexican hat function-CWT and Daubechies7-CWT (mexh-CWT and db7-CWT, respectively) were found to be suitable for the transformation of the original UV spectra. In the following procedure, mexh-CWT and Coiflets3-CWT (coif3-CWT) were found to be appropriate for the signal analysis of ratio spectra (RS) of VAL/HCT and HCT/VAL. Calibration graphs for VAL and HCT were obtained by measuring db7-CWT and mexh-CWT amplitudes in the transformation of the original absorption spectra and RS-coif-CWT and RS-mexh-CWT amplitudes in the transformation of the ratio spectra. The validity and applicability of the proposed CWT methods were evaluated through the analysis of an independent set of synthetic binary mixtures consisting of VAL and HCT. The proposed signal processing methods were then successfully applied to the simultaneous quantitative evaluation and simultaneous dissolution profiles of the related drugs in commercial tablets, with good agreement reported for the experimental results

    Application of Continuous Wavelet Transform to the Analysis of the Modulus of the Fractional Fourier Transform Bands for Resolving Two Component Mixture

    Get PDF
    In this paper, the fractional Fourier transform (FrFT) is applied to the spectral bands of two component mixture containing oxfendazole and oxyclozanide to provide the multicomponent quantitative prediction of the related substances. With this aim in mind, the modulus of FrFT spectral bands are processed by the continuous Mexican Hat family of wavelets, being denoted by MEXH-CWT-MOFrFT. Four modulus sets are obtained for the parameter a of the FrFT going from 0.6 up to 0.9 in order to compare their effects upon the spectral and quantitative resolutions. Four linear regression plots for each substance were obtained by measuring the MEXH-CWT-MOFrFT amplitudes in the application of the MEXH family to the modulus of the FrFT. This new combined powerful tool is validated by analyzing the artificial samples of the related drugs, and it is applied to the quality control of the commercial veterinary samples

    Continuous wavelet transform methods for the simultaneous determinations and dissolution profiles of valsartan and hydrochlorothiazide in tablets

    Get PDF
    ABSTRACT Continuous wavelet transform (CWT) was proposed for the simultaneous determination and dissolution profiles of valsartan (VAL) and hydrochlorothiazide (HCT) in tablets, without the use of a chemical separation procedure. The CWT approach was applied to the original UV spectra and their ratio spectra in the optimal wavelength ranges. After testing several wavelet families, Mexican hat function-CWT and Daubechies7-CWT (mexh-CWT and db7-CWT, respectively) were found to be suitable for the transformation of the original UV spectra. In the following procedure, mexh-CWT and Coiflets3-CWT (coif3-CWT) were found to be appropriate for the signal analysis of ratio spectra (RS) of VAL/HCT and HCT/VAL. Calibration graphs for VAL and HCT were obtained by measuring db7-CWT and mexh-CWT amplitudes in the transformation of the original absorption spectra and RS-coif-CWT and RS-mexh-CWT amplitudes in the transformation of the ratio spectra. The validity and applicability of the proposed CWT methods were evaluated through the analysis of an independent set of synthetic binary mixtures consisting of VAL and HCT. The proposed signal processing methods were then successfully applied to the simultaneous quantitative evaluation and simultaneous dissolution profiles of the related drugs in commercial tablets, with good agreement reported for the experimental results
    • …
    corecore