50 research outputs found

    Evaluation of the relationship between capillary and venous plasma glucose concentrations obtained by the HemoCue Glucose 201+ system during an oral glucose tolerance test

    Get PDF
    Abstract In 55 women with previous gestational diabetes mellitus, simultaneous capillary and venous plasma glucose concentrations were measured at 0, 30 and 120 min during a 75 g oral glucose tolerance test (OGTT). The aims of the study were to examine the relationship between capillary and venous glucose measurements, and to establish equations for the conversion of capillary and venous glucose concentrations using the HemoCue Glucose 201+ system. Additionally, the correlation between the capillary and venous glucose concentrations with the diagnostic cut-off limits proposed by the World Health Organization (WHO) in 1999 was evaluated. Capillary glucose concentrations were consistently higher than venous glucose concentrations at all time points of the OGTT (p < 0.001), and the correlations between the measurements were statistically highly significant (p < 0.001). The differences between the samples were greatest in the non-fasting state as revealed by the 95% prediction intervals (mmol/L) in Bland-Altman plots; ? 0.54 at 0 min, ? 2.01 at 30 min, and ? 1.35 at 120 min. Equivalence values for capillary plasma glucose concentrations derived from this study tended to be higher than those proposed by the WHO as diagnostic cut-off limits. Stratifying subjects by glucose tolerance status according to the WHO criteria revealed disagreements related to glucose values close to the diagnostic cut-off points. The study findings highlight the uncertainty associated with derived equivalence values. However, capillary plasma glucose measurements could be suitable for diagnostic purposes in epidemiological studies and when translating results on a group basis

    Development of a diagnostic protocol for dizziness in elderly patients in general practice: a Delphi procedure

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Dizziness in general practice is very common, especially in elderly patients. The empirical evidence for diagnostic tests in the evaluation of dizziness is scarce. Aim of our study was to determine which set of diagnostic tests should be part of a diagnostic protocol for evaluating dizziness in elderly patients in general practice.</p> <p>Methods</p> <p>We conducted a Delphi procedure with a panel of 16 national and international experts of all relevant medical specialities in the field of dizziness. A selection of 36 diagnostic tests, based on a systematic review and practice guidelines, was presented to the panel. Each test was described extensively, and data on test characteristics and methodological quality (assessed with the Quality Assessment of Diagnostic Accuracy Studies, QUADAS) were presented. The threshold for in- or exclusion of a diagnostic test was set at an agreement of 70%.</p> <p>Results</p> <p>During three rounds 21 diagnostic tests were selected, concerning patient history (4 items), physical examination (11 items), and additional tests (6 items). Five tests were excluded, although they are recommended by existing practice guidelines on dizziness. Two tests were included, although several practice guidelines question their diagnostic value. Two more tests were included that have never been recommended by practice guidelines on dizziness.</p> <p>Conclusion</p> <p>In this study we successfully combined empirical evidence with expert opinion for the development of a set of diagnostic tests for evaluating dizziness in elderly patients. This comprehensive set of tests will be evaluated in a cross-sectional diagnostic study.</p

    Criteria for the use of omics-based predictors in clinical trials: Explanation and elaboration

    Get PDF
    High-throughput 'omics' technologies that generate molecular profiles for biospecimens have been extensively used in preclinical studies to reveal molecular subtypes and elucidate the biological mechanisms of disease, and in retrospective studies on clinical specimens to develop mathematical models to predict clinical endpoints. Nevertheless, the translation of these technologies into clinical tests that are useful for guiding management decisions for patients has been relatively slow. It can be difficult to determine when the body of evidence for an omics-based test is sufficiently comprehensive and reliable to support claims that it is ready for clinical use, or even that it is ready for definitive evaluation in a clinical trial in which it may be used to direct patient therapy. Reasons for this difficulty include the exploratory and retrospective nature of many of these studies, the complexity of these assays and their application to clinical specimens, and the many potential pitfalls inherent in the development of mathematical predictor models from the very high-dimensional data generated by these omics technologies. Here we present a checklist of criteria to consider when evaluating the body of evidence supporting the clinical use of a predictor to guide patient therapy. Included are issues pertaining to specimen and assay requirements, the soundness of the process for developing predictor models, expectations regarding clinical study design and conduct, and attention to regulatory, ethical, and legal issues. The proposed checklist should serve as a useful guide to investigators preparing proposals for studies involving the use of omics-based tests. The US National Cancer Institute plans to refer to these guidelines for review of proposals for studies involving omics tests, and it is hoped that other sponsors will adopt the checklist as well. © 2013 McShane et al.; licensee BioMed Central Ltd

    A comparison of stability of chemical analytes in plasma from the BD Vacutainer (R) Barricor (TM) tube with mechanical separator versus tubes containing gel separator

    No full text
    Background: There is a need of prolonged stability of certain chemical analytes in lithium heparin tubes with separators. A new tube with a mechanical separator has recently been launched (Barricor (TM)), which according to the manufacturer may have these benefits. The aim of this study was to evaluate stability performance of this tube in comparison with plasma gel tubes under clinically realistic circumstances. Methods: Blood was collected in tubes containing lithium heparin with different separators; gel separator (Vacutainer (R) PST (TM), Becton Dickinson and Vacuette (R), Greiner bio-one) and mechanical separator (Vacutainer (R) Barricor (TM), Becton Dickinson). All tubes had an aspiration volume of 3 mL and were centrifuged at similar time and force. Tubes were transported manually or by car. Seven analytes from 122 patients were analyzed after 3 to 80 hours by Cobas c701 (Roche). Results The Barricor (TM) tube showed increased stability of phosphate and potassium and similar stability of aspartate aminotransferase, glucose, homocysteine, lactate dehydrogenase, and magnesium compared with gel tubes. Maximal allowable bias for phosphate was exceeded after 68 hours for Barricor (TM) tubes compared with 29 or 35 hours for gel tubes and for potassium after 40 hours for Barricor (TM) tubes vs 9 or 12 hours for gel tubes. Transportation did not affect stability. Hemolysis index was slightly lower in Barricor tubes than in gel tubes (P = .01). Conclusion Implementing the new Barricor (TM) tube will improve stability of potassium and phosphate in plasma. Blood sampling facilities far from the laboratory may benefit from using these tubes, thus diminishing preanalytical errors