31 research outputs found
Dose-finding study of a 90-day contraceptive vaginal ring releasing estradiol and segesterone acetate.
ObjectiveTo evaluate serum estradiol (E2) concentrations during use of 90-day contraceptive vaginal rings releasing E2 75, 100, or 200 mcg/day and segesterone acetate (SA) 200 mcg/day to identify a dose that avoids hypoestrogenism.Study designWe conducted a multicenter dose-finding study in healthy, reproductive-aged women with regular cycles with sequential enrollment to increasing E2 dose groups. We evaluated serum E2 concentrations twice weekly for the primary outcome of median E2 concentrations throughout initial 30-day use (target ≥40 pg/mL). In an optional 2-cycle extension substudy, we randomized participants to 2- or 4-day ring-free intervals per 30-day cycle to evaluate bleeding and spotting based on daily diary information.ResultsSixty-five participants enrolled in E2 75 (n = 22), 100 (n = 21), and 200 (n = 22) mcg/day groups; 35 participated in the substudy. Median serum E2 concentrations in 75 and 100 mcg/day groups were <40 pg/mL. In the 200 mcg/day group, median E2 concentrations peaked on days 4-5 of CVR use at 194 pg/mL (range 114-312 pg/mL) and remained >40 pg/mL throughout 30 days; E2 concentrations were 37 pg/mL (range 28-62 pg/mL) on days 88-90 (n = 11). Among the E2 200 mcg/day substudy participants, all had withdrawal bleeding following ring removal. The 2-day ring-free interval group reported zero median unscheduled bleeding and two (range 0-16) and three (range 0-19) unscheduled spotting days in extension cycles 1 and 2, respectively. The 4-day ring-free interval group reported zero median unscheduled bleeding or spotting days.ConclusionsEstradiol concentrations with rings releasing E2 200 mcg/day and SA 200 mcg/day avoid hypoestrogenism over 30-day use.ImplicationsA 90-day contraceptive vaginal ring releasing estradiol 200 mcg/day and segesterone acetate 200 mcg/day achieves estradiol concentrations that should avoid hypoestrogenism and effectively suppresses ovulation
Efficacy of the 1-year (13-cycle) segesterone acetate and ethinylestradiol contraceptive vaginal system : results of two multicentre, open-label, single-arm, phase 3 trials
A ring-shaped, contraceptive vaginal system designed to last 1 year (13 cycles) delivers an average of 0.15 mg segesterone acetate and 0.013 mg ethinylestradiol per day. We evaluated the efficacy of this contraceptive vaginal system and return to menses or pregnancy after use. In two identically designed, multicentre, open-label, single-arm, phase 3 trials (one at 15 US academic and community sites and one at 12 US and international academic and community sites), participants followed a 21-days-in, 7-days-out segesterone acetate and ethinylestradiol contraceptive vaginal system schedule for up to 13 cycles. Participants were healthy, sexually active, non-pregnant, non-sterilised women aged 18-40 years. Women were cautioned that any removals during the 21 days of cyclic use should not exceed 2 h, and used daily paper diaries to record vaginal system use. Consistent with regulatory requirements for contraceptives, we calculated the Pearl Index for women aged 35 years and younger, excluding adjunctive contraception cycles, as the primary efficacy outcome measure. We also did intention-to-treat Kaplan-Meier life table analyses and followed up women who did not use hormonal contraceptives or desired pregnancy after study completion for 6 months for return to menses or pregnancy. The trials are registered with ClinicalTrials.gov, numbers NCT00455156 and NCT00263341. Between Dec 19, 2006, and Oct 9, 2009, at the 15 US sites, and between Nov 1, 2006, and July 2, 2009, at the 12 US and international sites we enrolled 2278 women. Our overall efficacy analysis included 2265 participants (1130 in the US study and 1135 in the international study) and 1303 (57.5%) participants completed up to 13 cycles. The Pearl Index for the primary efficacy group was 2.98 (95% CI 2.13-4.06) per 100 woman-years, and was well within the range indicative of efficacy for a contraceptive under a woman's control. The Kaplan-Meier analysis revealed the contraceptive vaginal system was 97.5% effective, which provided further evidence of efficacy. Pregnancy occurrence was similar across cycles. All 290 follow-up participants reported return to menses or became pregnant (24 [63%] of 38 women who desired pregnancy) within 6 months. Interpretation The segesterone acetate and ethinylestradiol contraceptive vaginal system is an effective contraceptive for 13 consecutive cycles of use. This new product adds to the contraceptive method mix and the 1-year duration of use means that women do not need to return to the clinic or pharmacy for refills every few months78e1054e1064We thank The Eunice Kennedy Shriver National Institute of Child Health and Human Development of the National Institutes of Health (NICHD), the US Agency for International Development (USAID), and WHO for funding the phase 3 studies. We also acknowledge all participating study investigators (appendix p 1) and coordinators at the 27 clinical sites for conduct of the two phase 3 clinical trials and the over 2200 women participants from eight countries. We further acknowledge the medical writing assistance of Kathleen Ohleth (Precise Publications; Bedminster. NJ, USA) supported by TherapeuticsMD (Boca Raton, FL, USA). The NICHD (contract no HHSN27500403372) funded and conducted the US study and USAID (grant no GPO-A-00-04-00019-00) funded the international study, which was conducted by the Population Council. WHO Department of Reproductive Health and Research funded two international study sites. Medical writing support for manuscript submission and resubmission was supported by TherapeuticsMD. The authors acknowledge the major contribution of Daniel R Mishell Jr (deceased), from the Department of Obstetrics and Gynecology, University of Southern California, Keck School of Medicine (Los Angeles, CA, USA) who invented the concept of the vaginal system to deliver contraceptive steroids, did many of the clinical studies for the segesterone acetate and ethinylestradiol contraceptive vaginal system, and was a principle investigator for the 300 B phase 3 study analysed in this Article while a member of the International Committee for Contraceptive Research (ICCR) of the Population Council. The authors also gratefully acknowledge the contribution of Horacio B Croxatto, from the University of Chile (Santiago, Chile), who established the clinical centre in Chile, participated in all pivotal clinical studies for this ring, and provided guidance for the full development of this new contraceptive while a member of the ICC
Lysozyme and RNases as anti-HIV components in β-core preparations of human chorionic gonadotropin
Human chorionic gonadotropin (hCG) preparations contain activity against HIV type 1 (HIV-1). However, there has been controversy about whether some biological activities of hCG β-subunit (hCGβ) preparations are caused by the β-subunit itself or other proteins present in the preparations. We report here the purification, characterization, and identification of three enzymes with anti-HIV activity present in the β-core fraction of hCGβ prepared from the urine of pregnant women. The N-terminal amino acid sequence of one protein is identical to human urinary lysozyme C, and those of the other two are identical to human RNase A and urinary RNase U. We thus refer to these proteins as AVL (antiviral lysozyme) and AVR (antiviral RNases). In addition to HIV-1 inhibition, AVL is capable of lysing Micrococcus lysodeikticus. AVR digests a variety of RNA substrates, including RNA from HIV-1-infected cells. We also find that lysozyme from chicken egg white, human milk, and human neutrophils and RNase A from bovine pancreas possess activity against HIV-1. These findings may offer additional strategies for the treatment of HIV-1 infection
Recommended from our members
Menstrual cup use and intrauterine device expulsion in a copper intrauterine device randomized trial
ObjectiveTo evaluate menstrual cup use and intrauterine device (IUD) expulsion.Study designWe performed a secondary analysis of a 3-year contraceptive efficacy trial comparing two copper 380 mm2 IUDs. Investigators randomized participants approximately 1:4 to the TCu380A or NTCu380-Mini IUD. Approximately 12 months after enrollment began, we advised participants against menstrual cup use due to observed IUD expulsions in cup users. We evaluated IUD expulsion (including spontaneous partial and complete expulsion and accidental self-removal) at 12 and 36 months. We used multivariable logistic regression to evaluate IUD expulsion by age, baseline menstrual volume, body mass index, IUD type, menstrual cup use, parity, and uterine length.ResultsThis analysis included 1046 participants (203 TCu380A and 843 NTCu380-Mini), with 879 (84.0%) nulliparas. Through 12 and 36 months, expulsion occurred in 74 (7.1%, 95% CI 5.5-8.6%) and 133 (12.7%, 95% CI 10.7-14.7%) participants, respectively. Overall, 250 (23.9%) reported menstrual cup use. More menstrual cup users than non-users experienced expulsion through 12 months (32/203 [15.8%] vs. 42/843 [5.0%]) and 36 months (58/250 [23.2%] vs. 75/796 [9.4%]). Through 36 months, NTCu380-Mini menstrual cup users had higher expulsion odds, while TCu380A cup users did not. Menstrual cup users more frequently experienced accidental self-removal than non-users in participants using the TCu380A (3/53 [5.7%] vs. 0/150 [0.0%]) and the NTCu380-Mini (20/197 [10.2%] vs. 7/646 [1.1%]). In multivariable regression, we found increased odds of expulsion through 36 months in participants using menstrual cups with the NTCu380-Mini (aOR 3.13, 95% CI 1.16-8.46) and <25 years (aOR 1.59, 95% CI 1.07-2.34).ConclusionsWe found higher odds of IUD expulsion with menstrual cup and concurrent NTCu380-Mini IUD use over 36 months of use, but not with concurrent TCu380A IUD use. Menstrual cup users experienced higher likelihood of accidental self-removal regardless of IUD type.ImplicationsMenstrual cup and NTCu380-Mini use may increase IUD expulsion risk and may increase accidental self-removal risk with TCu380A and NTCu380-Mini use. Clinicians should advise patients of these risks and consider warning patients using an IUD shaped like the NTCu380-Mini (Nova-T frames) of expulsion risk with menstrual cup use
Recommended from our members
Male contraception development: monitoring effective spermatogenesis suppression utilizing a user-controlled sperm concentration test compared with standard semen analysis
ObjectiveTo determine whether a user-controlled sperm concentration test compared with standard semen analysis can effectively monitor spermatogenesis suppression for male contraception.DesignSingle center, prospective sub study of the ongoing clinical trial: "Study of daily application of Nestorone and testosterone combination gel for male contraception."SettingResearch institute at an academic medical center.Participant(s)Couples participating in the male contraceptive clinical trial.InterventionsNone.Main outcome measure(s)The ability by participants to monitor sperm suppression to a threshold compatible with contraceptive efficacy utilizing a user-controlled test verified by sperm concentration determined by standard laboratory methods.Result(s)Thirty-eight men participating in a hormonal male contraceptive clinical trial provided multiple samples during spermatogenesis suppression for this substudy. Participants, employing a user-controlled test, correctly identified the absence of sperm (a negative test) in 100% of their laboratory-confirmed azoospermic samples (n = 122). Participants also identified 100% of samples (n = 73) with sperm >0.2 million/mL as positive. Sperm counts between 0.01 and 0.2 million/mL were identified as negative in 96% of samples. Trial participants noted the overall ease of using the test with respect to sample preparation, test timing, and result interpretation, and that they could accurately use this test at home without difficulty.Conclusion(s)Participants undergoing spermatogenesis suppression in a hormonal male contraceptive trial performed user-controlled test to determine whether their semen sperm concentration was ≤ or >0.2 million/mL. Compared with standard semen analyses, participants correctly identified 100% of samples with sperm counts >0.2 million/mL as positive (Sensitivity 100%). A positive result when the couple is using a male contraceptive method triggers the need for semen analysis by a laboratory while the couple uses another method of contraception. Participants correctly diagnosed samples ≤0.2 million sperm/mL as negative in 99% of samples (specificity 99%). A negative result indicates a sperm concentration ≤0.2 million/mL, well below the threshold of ≤1 million/mL offering contraceptive efficacy demonstrated by prior studies. At-home sperm concentration test would minimize the need for users to return to the clinic to monitor suppression of spermatogenesis, decreasing cost and burden of male contraception trials and increasing practicality of the method.Clinical trial registration numberNCT: 03452111
Prevalence and cumulative incidence rates of vaginal infections and urogenital infections in women in the substudy and remainder of women in Phase III trial.
<p>Prevalence and cumulative incidence rates of vaginal infections and urogenital infections in women in the substudy and remainder of women in Phase III trial.</p
Change in vaginal infections and selected vaginal microbiota by assessment visit and the comparison of vaginal culture and ring culture.
<p>Visit timing: Cycle 6 (targeted at Day 144 [beginning of Cycle 6], range 2 to 251); Cycle 13 (targeted at Day 358 [12 cycles plus 21 days of use during cycle 13], range 252 to 358).</p><p># One subject without Nugent Score data at screening.</p><p>* McNemar’s tests: p<0.05.</p><p>** Performed at study exit (Cycle 13 [n = 58] or early discontinuation visit [n = 14]).</p><p>Change in vaginal infections and selected vaginal microbiota by assessment visit and the comparison of vaginal culture and ring culture.</p
Subjects’ disposition chart in microbiology study.
<p>* Thirteen cases of abnormal pap smear, one current PID, one vaginal cyst, three migraines or headaches, one heavy smoking, one drug abuse, two hypertension, one abnormal blood cholesterol, one abnormal urine test. ** One in another study, one employed in the office. <sup>&</sup>Visit timing: Cycle 6 (targeted at Day 144 [beginning of Cycle 6], range 2 to 251); Cycle 13 (targeted at Day 358 [12 cycles plus 21 days of use during cycle 13], range 252 to 358).</p
Demographic and baseline characteristics among substudy participants.
<p>*p<0.05</p><p>**Multiple choices allowed per subject. Seven subjects did not respond.</p><p>*** Other includes abstinence, rhythm method, and transdermal patch.</p><p>Demographic and baseline characteristics among substudy participants.</p