567 research outputs found
Transcriptional, epigenetic and pharmacological control of JAK/STAT pathway in NK cells
Differentiation of Natural Killer (NK) cells is a stepwise process having its origin in the bone marrow and proceeding in the periphery, where these cells follow organ specific trajectories. Several soluble factors and cytokines regulate the distinct stages of NK cell differentiation, and ultimately, their functional properties. Cytokines activating the Janus kinases (JAKs) and members of the signal transducer and activator of transcription (STAT) pathway control distinct aspects of NK cell biology, ranging from development, terminal differentiation, activation, and generation of cells with adaptive properties. Here, we discuss how the recent advances of next generation sequencing (NGS) technology have led to unravel novel molecular aspects of gene regulation, with the aim to provide genomic views of how STATs regulate transcriptional and epigenetic features of NK cells during the different functional stages
SARS-CoV-2 diagnostics in the virology laboratory of a University Hospital in Rome during the lockdown period
Italy was one of the most affected nations by coronavirus disease 2019 outside China. The infections, initially limited to Northern Italy, spread to all other Italian regions. This study aims to provide a snapshot of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) epidemiology based on a single-center laboratory experience in Rome. The study retrospectively included 6565 subjects tested for SARS-CoV-2 at the Laboratory of Virology of Sapienza University Hospital in Rome from 6 March to 4 May. A total of 9995 clinical specimens were analyzed, including nasopharyngeal swabs, bronchoalveolar lavage fluids, gargle lavages, stools, pleural fluids, and cerebrospinal fluids. Positivity to SARS-CoV-2 was detected in 8% (527/6565) of individuals, increased with age, and was higher in male patients (P <.001). The number of new confirmed cases reached a peak on 18 March and then decreased. The virus was detected in respiratory samples, in stool and in pleural fluids, while none of gargle lavage or cerebrospinal fluid samples gave a positive result. This analysis allowed to gather comprehensive information on SARS-CoV-2 epidemiology in our area, highlighting positivity variations over time and in different sex and age group and the need for a continuous surveillance of the infection, mostly because the pandemic evolution remains unknown
Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments
Measurement of Through-Going Particle Momentum By Means Of Multiple Scattering With The ICARUS T600 TPC
The ICARUS collaboration has demonstrated, following the operation of a 600
ton (T600) detector at shallow depth, that the technique based on liquid Argon
TPCs is now mature. The study of rare events, not contemplated in the Standard
Model, can greatly benefit from the use of this kind of detectors. In
particular, a deeper understanding of atmospheric neutrino properties will be
obtained thanks to the unprecedented quality of the data ICARUS provides.
However if we concentrate on the T600 performance, most of the
charged current sample will be partially contained, due to the reduced
dimensions of the detector. In this article, we address the problem of how well
we can determine the kinematics of events having partially contained tracks.
The analysis of a large sample of atmospheric muons collected during the T600
test run demonstrate that, in case the recorded track is at least one meter
long, the muon momentum can be reconstructed by an algorithm that measures the
Multiple Coulomb Scattering along the particle's path. Moreover, we show that
momentum resolution can be improved by a factor two using an algorithm based on
the Kalman Filtering technique
Performance Of A Liquid Argon Time Projection Chamber Exposed To The WANF Neutrino Beam
We present the results of the first exposure of a Liquid Argon TPC to a
multi-GeV neutrino beam. The data have been collected with a 50 liters
ICARUS-like chamber located between the CHORUS and NOMAD experiments at the
CERN West Area Neutrino Facility (WANF). We discuss both the instrumental
performance of the detector and its capability to identify and reconstruct low
multiplicity neutrino interactions.Comment: 14 pages, 12 figures. Submitted for publication to Physical Review
Discovery of underground argon with low level of radioactive 39Ar and possible applications to WIMP dark matter detectors
We report on the first measurement of 39Ar in argon from underground natural
gas reservoirs. The gas stored in the US National Helium Reserve was found to
contain a low level of 39Ar. The ratio of 39Ar to stable argon was found to be
<=4x10-17 (84% C.L.), less than 5% the value in atmospheric argon
(39Ar/Ar=8x10-16). The total quantity of argon currently stored in the National
Helium Reserve is estimated at 1000 tons. 39Ar represents one of the most
important backgrounds in argon detectors for WIMP dark matter searches. The
findings reported demonstrate the possibility of constructing large multi-ton
argon detectors with low radioactivity suitable for WIMP dark matter searches.Comment: 6 pages, 2 figures, 2 table
Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN
A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed
in order to definitely clarify the possible existence of additional neutrino
states, as pointed out by neutrino calibration source experiments, reactor and
accelerator experiments and measure the corresponding oscillation parameters.
The experiment is based on two identical LAr-TPCs complemented by magnetized
spectrometers detecting electron and muon neutrino events at Far and Near
positions, 1600 m and 300 m from the proton target, respectively. The ICARUS
T600 detector, the largest LAr-TPC ever built with a size of about 600 ton of
imaging mass, now running in the LNGS underground laboratory, will be moved at
the CERN Far position. An additional 1/4 of the T600 detector (T150) will be
constructed and located in the Near position. Two large area spectrometers will
be placed downstream of the two LAr-TPC detectors to perform charge
identification and muon momentum measurements from sub-GeV to several GeV
energy range, greatly complementing the physics capabilities. This experiment
will offer remarkable discovery potentialities, collecting a very large number
of unbiased events both in the neutrino and antineutrino channels, largely
adequate to definitely settle the origin of the observed neutrino-related
anomalies.Comment: Contribution to the European Strategy for Particle Physics - Open
Symposium Preparatory Group, Kracow 10-12 September 201
Measurement of the muon decay spectrum with the ICARUS liquid Argon TPC
Examples are given which prove the ICARUS detector quality through relevant
physics measurements. We study the muon decay energy spectrum from a sample of
stopping muon events acquired during the test run of the ICARUS T600 detector.
This detector allows the spatial reconstruction of the events with fine
granularity, hence, the precise measurement of the range and dE/dx of the muon
with high sampling rate. This information is used to compute the calibration
factors needed for the full calorimetric reconstruction of the events. The
Michel rho parameter is then measured by comparison of the experimental and
Monte Carlo simulated muon decay spectra, obtaining rho = 0.72 +/- 0.06(stat.)
+/- 0.08(syst.). The energy resolution for electrons below ~50 MeV is finally
extracted from the simulated sample, obtaining (Emeas-Emc)/Emc =
11%/sqrt(E[MeV]) + 2%.Comment: 16 pages, 8 figures, LaTex, A4. Some text and 1 figure added. Final
version as accepted for publication in The European Physical Journal
Oxygen contamination in liquid Argon: combined effects on ionization electron charge and scintillation light
A dedicated test of the effects of Oxygen contamination in liquid Argon has
been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP
R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a
small (0.7 lt) dedicated detector, coupled with a system for the injection of
controlled amounts of gaseous Oxygen. Purpose of the test with the 0.7 lt
detector is to detect the reduction of the long-lived component lifetime of the
Argon scintillation light emission at increasing O2 concentration. Data from
the WArP prototype are used for determining the behavior of both the ionization
electron lifetime and the scintillation long-lived component lifetime during
the O2-purification process activated in closed loop during the acquisition
run. The electron lifetime measurements allow to infer the O2 content of the
Argon and correlate it with the long-lived scintillation lifetime data. The
effect of Oxygen contamination on the scintillation light has been thus
measured over a wide range of O2 concentration, spanning from about 10^-3 ppm
up to about 10 ppm. The rate constant of the light quenching process induced by
Oxygen in LAr has been found to be k'(O2)=0.54+-0.03 micros^-1 ppm^-1
- âŠ