5,218 research outputs found

    Holocene slip rate variability along the Pernicana fault system (Mt. Etna, Italy): Evidence from offset lava flows

    Get PDF
    The eastern flank of the Mount Etna stratovolcano is affected by extension and is slowly sliding eastward into the Ionian Sea. The Pernicana fault system forms the border of the northern part of this sliding area. It consists of three E-W−oriented fault sectors that are seismically active and characterized by earthquakes up to 4.7 in magnitude (M) capable of producing ground rupture and damage located mainly along the western and central sectors, and by continuous creep on the eastern sector. A new topographic study of the central sector of the Pernicana fault system shows an overall bell-shaped profile, with maximum scarp height of 35 m in the center of the sector, and two local minima that are probably due to the complex morphological relation between fault scarp and lava flows. We determined the ages of lava flows cut by the Pernicana fault system at 12 sites using cosmogenic 3He and 40Ar/39Ar techniques in order to determine the recent slip history of the fault. From the displacement-age relations, we estimate an average throw rate of ∼2.5 mm/yr over the last 15 k.y. The slip rate appears to have accelerated during the last 3.5 k.y., with displacement rates of up to ∼15 mm/yr, whereas between 3.5 and 15 ka, the throw rate averaged ∼1 mm/yr. This increase in slip rate resulted in significant changes in seismicity rates, for instance, decreasing the mean recurrence time of M ≥ 4.7 earthquakes from ∼200 to ∼20 yr. Based on empirical relationships, we attribute the variation in seismic activity on the Pernicana fault system to factors intrinsic to the system that are likely related to changes in the volcanic system. These internal factors could be fault interdependencies (such as those across the Taupo Rift, New Zealand) or they could represent interactions among magmatic, tectonic, and gravitational processes (e.g., Kīlauea volcano, Hawaii). Given their effect on earthquake recurrence intervals, these interactions need to be fully assessed in seismic hazard evaluations

    Prospects for Stochastic Background Searches Using Virgo and LSC Interferometers

    Full text link
    We consider the question of cross-correlation measurements using Virgo and the LSC Interferometers (LIGO Livingston, LIGO Hanford, and GEO600) to search for a stochastic gravitational-wave background. We find that inclusion of Virgo into the network will substantially improve the sensitivity to correlations above 200 Hz if all detectors are operating at their design sensitivity. This is illustrated using a simulated isotropic stochastic background signal, generated with an astrophysically-motivated spectrum, injected into 24 hours of simulated noise for the LIGO and Virgo interferometers.Comment: 11 pages, uses IOP style files, submitted to CQG for GWDAW11 proceedings; revised in response to referee comment

    Decrypting geophysical signals at Stromboli Volcano (Italy): Integration of seismic and Ground-Based InSAR displacement data

    Get PDF
    We present the integration of seismic and Ground‐Based Interferometric Synthetic Aperture Radar system (GBInSAR) displacement data at Stromboli Volcano. Ground deformation in the area of summit vents is positively correlated with both seismic tremor amplitude and cumulative amplitudes of very long period (VLP) signals associated with Strombolian explosions. Changes in VLP amplitudes precede by a few days the variations in ground deformation and seismic tremor. We propose a model where the arrival of fresh, gas‐rich magma from depth enhances gas slug formation, promoting convection and gas transfer throughout the conduit system. At the shallowest portion of the conduit, an increase in volatile content causes a density decrease, expansion of the magmatic column and augmented degassing activity, which respectively induce inflation of the conduit, and increased tremor amplitudes. The temporal delay between increase of VLP and tremor amplitudes/conduit inflation can be interpreted in terms of the different timescales characterizing bulk gas transfer versus slug formation and ascent

    Attosecond Streaking in the Water Window: A New Regime of Attosecond Pulse Characterization

    Full text link
    We report on the first streaking measurement of water-window attosecond pulses generated via high harmonic generation, driven by sub-2-cycle, CEP-stable, 1850 nm laser pulses. Both the central photon energy and the energy bandwidth far exceed what has been demonstrated thus far, warranting the investigation of the attosecond streaking technique for the soft X-ray regime and the limits of the FROGCRAB retrieval algorithm under such conditions. We also discuss the problem of attochirp compensation and issues regarding much lower photo-ionization cross sections compared with the XUV in addition to the fact that several shells of target gases are accessed simultaneously. Based on our investigation, we caution that the vastly different conditions in the soft X-ray regime warrant a diligent examination of the fidelity of the measurement and the retrieval procedure.Comment: 14 Pages, 12 figure

    Anatomical and functional changes after dexamethasone implant and ranibizumab in diabetic macular edema: A retrospective cohort study

    Get PDF
    AIM: To investigate the efficacy and safety of ranibizumab (RZB group) and dexamethasone implant (DEX group) intravitreal treatments in patients with treatment-na\uefve center involved diabetic macular edema (DME) by means of functional and morphological assessments. METHODS: This retrospective cohort study included 50 eyes of 50 patients with DME treated either with RBZ or DEX. Best-corrected visual acuity (BCVA) and microperimetry were evaluated at baseline and during a 6-month follow-up. In addition, central macular thickness (CMT) by means of structural optical coherence tomography (OCT) and retinal capillary plexus density and choriocapillary density by means of OCT angiography were assessed in all cases. RESULTS: Functional and morphological parameters significantly improved during the study period in both groups. BCVA improved significantly in both groups with a greater increase in the DEX group compared to the RBZ group (P=0.030). Microperimetry significantly differed during follow-up between the two treatments (P=0.031). In both groups CMT significantly decreased (P<0.001) without statistically significant differences between the two groups. A statistically significant increase of deep capillary plexus density was detected in both groups at 30d after therapy. The retreatment rate was 0.70\ub10.10 and 0.65\ub10.10 in the RBZ group and 0.65\ub10.10 and 0.50\ub10.11 in DEX group at 120 and 180d respectively. Two out of 25 patients in DEX group showed intraocular pressure increase requiring hypotonic eye drops. CONCLUSION: Both treatments are very effective for DME treatment during 6mo of follow-up with a lower retreatment rate in DEX group

    Functional and structural reliability of optic nerve head measurements in healthy eyes by means of optical coherence tomography angiography

    Get PDF
    Background and Objectives: the aim of the study was to evaluate the repeatability and reproducibility of optical microangiography (OMAG)-based optical coherence tomography angiography (OCTA) in the optic nerve head (ONH) and radial peripapillary capillary (RPC) perfusion assessment of healthy eyes. Materials and Methods: in this observational study, a total of 40 healthy subjects underwent ONH evaluation, using an OMAG-based OCTA system at baseline (T0), after 30 min (T1), and after 7 days (T2). The main outcome measures were the vessel density (VD) and flux index (FI) of the RPCs, as well as peri-papillary retinal nerve fibre layer (pRNFL) thickness. The analysis was performed by two observers independently. The coefficient of repeatability (CR), within the subject coefficient of variation (CVw) and intrasession correlation coefficient (ICC), to evaluate intrasession repeatability of measurements was calculated for each observer. Results: the high intrasession and intersession repeatability and reproducibility were assessed in the two observers for all three outcome measures. Of note, the CRs for the first and the second observer were 0.011 (95% confidence interval (CI) 0.009–0.014) and 0.016 (95% CI 0.013–0.020) for FI, 0.016 (95% CI 0.013–0.021) and 0.017 (95% CI 0.014–0.021) for VD, and 2.400 (95% CI 1.948–3.092) and 3.732 (95% CI 3.064–4.775) for pRNFL thickness, respectively. The agreement between them was excellent for pRNFL assessment and very good for FI and VD. Conclusion: OCTA has a great potential in the accurate assessment of ONH and peri-papillary microcirculation. It allows for repeated and reproducible measurements without multiple scans-related bias, thus guaranteeing an independent operator analysis with good reproducibility and repeatability

    The fate of the leptophobic Z'

    Get PDF
    We review the main features of the leptophobic-Z' phenomenology, commenting on the prospects of these models after the recent experimental results on R_c, R_b and after the recent theoretical analyses of jet production at the Tevatron

    An experimental multiprocessor system for distributed parallel computations.

    Get PDF
    The availability of low-cost microprocessor chips with efficient instruction sets for specific numerical tasks (signal processors) has been exploited for building a versatile multiprocessor system, consisting of a host minicomputer augmented by a number of joint processors. The host provides a multiuser-multitasking environment and manages system resources and task scheduling. User applications can call upon one or more joint processors for parallel execution of adequately partitioned, computationally intensive numeric operations. Each joint processor has sufficient local memory for storing procedures and data and has access to regions in host memory for shared data. Kernel processes in the host and in the joint processors provide the necessary mechanism for initialization and synchronization of the distributed parallel execution of procedures

    Asthma worsened by benzoate contained in some antiasthmatic drugs.

    Get PDF
    Here, we report our experience on benzoate hypersensitivity. Drug and food additives are known to induce pseudo-allergic reactions such as urticaria, eczema, asthma and rhinitis. These reactions are often under-diagnosed, above all in allergic patients treated with additive containing drugs. On the contrary, attention to additives present in some drug formulations and foods may often permit more correct diagnosis
    corecore