19 research outputs found

    Evidence of antineutrinos from distant reactors using pure water at SNO

    Get PDF
    The SNO+ Collaboration reports the first evidence of reactor antineutrinos in a Cherenkov detector. The nearest nuclear reactors are located 240 km away in Ontario, Canada. This analysis uses events with energies lower than in any previous analysis with a large water Cherenkov detector. Two analytical methods are used to distinguish reactor antineutrinos from background events in 190 days of data and yield consistent evidence for antineutrinos with a combined significance of 3.5σ

    Search for invisible modes of nucleon decay in water with the SNO+ detector

    Get PDF
    This paper reports results from a search for nucleon decay through invisible modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently deexcite, often emitting detectable gamma rays. A search for such gamma rays yields limits of 2.5×1029  y at 90% Bayesian credibility level (with a prior uniform in rate) for the partial lifetime of the neutron, and 3.6×1029  y for the partial lifetime of the proton, the latter a 70% improvement on the previous limit from SNO. We also present partial lifetime limits for invisible dinucleon modes of 1.3×1028  y for nn, 2.6×1028  y for pn and 4.7×1028  y for pp, an improvement over existing limits by close to 3 orders of magnitude for the latter two

    Optical calibration of the SNO+ detector in the water phase with deployed sources

    No full text
    SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. The calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume

    The SNO+ experiment

    No full text
    The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta (0νββ) decay will be conducted using 780 tonnes of liquid scintillator loaded with 3.9 tonnes of natural tellurium, corresponding to 1.3 tonnes of 130Te. This paper provides a general overview of the SNO+ experiment, including detector design, construction of process plants, commissioning efforts, electronics upgrades, data acquisition systems, and calibration techniques. The SNO+ collaboration is reusing the acrylic vessel, PMT array, and electronics of the SNO detector, having made a number of experimental upgrades and essential adaptations for use with the liquid scintillator. With low backgrounds and a low energy threshold, the SNO+ collaboration will also pursue a rich physics program beyond the search for 0νββ decay, including studies of geo- and reactor antineutrinos, supernova and solar neutrinos, and exotic physics such as the search for invisible nucleon decay. The SNO+ approach to the search for 0νββ decay is scalable: a future phase with high 130Te-loading is envisioned to probe an effective Majorana mass in the inverted mass ordering region

    The effect of nicotine on sensorimotor gating is modulated by a CHRNA3 polymorphism

    Full text link
    RATIONALE: Prepulse inhibition (PPI) of the acoustic startle response, a measure of sensorimotor gating, can be enhanced by nicotine. Moreover, the TT genotype of the nicotinic acetylcholine receptor (nAChR) α3-subunit (CHRNA3) rs1051730 polymorphism has previously been associated with diminished PPI and nicotine dependence. OBJECTIVES: We tested whether this CHRNA3 polymorphism also modulates the nicotine-induced enhancement of PPI. METHODS: We assessed the effect of nicotine on PPI, startle reactivity, and habituation in 52 healthy nonsmoking volunteers genotyped for CHRNA3 rs1051730 in a double-blind, placebo-controlled, counterbalanced, within-subjects design. Additionally, cotinine plasma levels were measured. RESULTS: Nicotine significantly enhanced PPI in TT homozygotes only and tended to worsen PPI in TC and CC carriers. Additionally, nicotine significantly reduced startle habituation. CONCLUSIONS: The present findings imply that the effect of nicotine on sensorimotor gating is modulated by nAChR α3-subunits. Thus, genetic variation in nicotinic receptor genes might be an important connecting link between early attentional processes and smoking behavior
    corecore