40 research outputs found
HIV-1 DNA/MVA vaccination reduces the per exposure probability of infection during repeated mucosal SHIV challenges
Historically, HIV vaccines specifically designed to raise cellular immunity resulted in protection from disease progression but not infection when tested in monkeys challenged with a single high virus exposure. An alternative approach, more analogous to human sexual exposures, is to repetitively challenge immunized monkeys with a much lower dose of virus until systemic infection is documented. Using these conditions to mimic human sexual transmission, we found that a multi-protein DNA/MVA HIV-1 vaccine is indeed capable of protecting rhesus monkeys against systemic infection when repeatedly challenged with a highly heterologous immunodeficiency virus (SHIV). Furthermore, this repetitive challenge approach allowed us to calculate per-exposure probability of infection, an observed vaccine efficacy of 64%, and undertake a systematic analysis for correlates of protection based on exposures needed to achieve infection. Therefore, improved non-human primate models for vaccine efficacy can provide novel insight and perhaps renew expectations for positive outcomes of human HIV clinical trials
Early Diagnosis of HIV Infection in Infants - One Caribbean and Six Sub-Saharan African Countries, 2011-2015.
Pediatric human immunodeficiency virus (HIV) infection remains an important public health issue in resource-limited settings. In 2015, 1.4 million children aged 50% decline. The most common challenges for access to testing for early infant diagnosis included difficulties in specimen transport, long turnaround time between specimen collection and receipt of results, and limitations in supply chain management. Further reductions in HIV mortality in children can be achieved through continued expansion and improvement of services for early infant diagnosis in PEPFAR-supported countries, including initiatives targeted to reach HIV-exposed infants, ensure access to programs for early infant diagnosis of HIV, and facilitate prompt linkage to treatment for children diagnosed with HIV infection
Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya.
Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya.Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma).Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2-99.2] and 98.1% [95%CI: 89.7-100]) and those for DBS (93.9% [95%CI: 88.8-97.2] and 88.0% [95%CI: 82.2-92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4-97.7) and 73.6 (95%CI: 51.6-86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6-100.0] vs. 94.7% [95%CI: 89.8-97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4-13.7] compared to DPS: 94.0%, [95% CI: 83.5-98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8-98.7] and 90.4% [95% CI 78.2-96.4] respectively. The optimum threshold was at 3000 cps/ml with an accuracy of 95.5%, sensitivity and specificity of 94.6% [95%CI 89.3-97.5] and 98.1% [95%CI 88.4-99.9]) respectively. The best threshold for CAP/CTM was at 4000 copies /mL, with 92.5% accuracy (sensitivity of 96.0% [95%CI 91.0-98.3] and specificity of 82.7% [95%CI 69.2-91.3]).There was similar performance between matched DBS, DPS and plasma using the Abbott test, and good correlation for matched DPS and plasma using the CAPCTM test. The findings suggest that DBS and DPS may be reliably used as alternative specimens to plasma to measure HIV-1 VL using Abbott, and DPS may be reliably used with CAP/CTM in resource-limited settings
Comparisons between CAP/CTM dried blood spot and Abbott dried blood spot tests at different cut-offs using CAP/CTM plasma as the gold standard.
<p>Comparisons between CAP/CTM dried blood spot and Abbott dried blood spot tests at different cut-offs using CAP/CTM plasma as the gold standard.</p
HIV-1 RNA detection rates of dried plasma spot (DPS) specimens paired with plasma specimens prepared from patient support centers in Nyanza, Kenya.
<p>(November 2012 to February 2013).</p
Concordance correlation analyses of HIV-1 (VL) quantification among plasma and DBS specimens collected from patients visiting Nyanza patient support centers and tested with CAP/CTM and Abbott.
<p><b>a)</b> CAP/CTM plasma vs. DBS VL; <b>b</b>) Abbott plasma vs. DBS VL.</p
Concordance correlation analyses of HIV-1 viral load (VL) quantification among plasma and dried plasma spot specimens collected from patients visiting Nyanza patient support centers and tested with CAP/CTM and Abbott.
<p><b>a)</b> CAP/CTM plasma vs. DPS VL; <b>b</b>) Abbott plasma vs. DPS VL.</p
HIV-1 RNA detection rates of dried blood spot (DBS) specimens paired with plasma specimens prepared from patient support centers in Nyanza, Kenya.
<p>(November 2012 to February 2013).</p