1,370 research outputs found
Monolithic Pixel Sensors in Deep-Submicron SOI Technology
Monolithic pixel sensors for charged particle detection and imaging
applications have been designed and fabricated using commercially available,
deep-submicron Silicon-On-Insulator (SOI) processes, which insulate a thin
layer of integrated full CMOS electronics from a high-resistivity substrate by
means of a buried oxide. The substrate is contacted from the electronics layer
through vias etched in the buried oxide, allowing pixel implanting and reverse
biasing. This paper summarizes the performances achieved with a first prototype
manufactured in the OKI 0.15 micrometer FD-SOI process, featuring analog and
digital pixels on a 10 micrometer pitch. The design and preliminary results on
the analog section of a second prototype manufactured in the OKI 0.20
micrometer FD-SOI process are briefly discussed.Comment: Proceedings of the PIXEL 2008 International Workshop, FNAL, Batavia,
IL, 23-26 September 2008. Submitted to JINST - Journal of Instrumentatio
An Umbrella Review of Aphasia Intervention descriPtion In Research: the AsPIRE project
Background: Recent reviews conclude that aphasia intervention is effective. However, replication and implementation require detailed reporting of intervention is and a specification of participant profiles. To date, reviews concentrate more on efficacy than on intervention reporting quality.
Aims : The aim of this project is to review the descriptions of aphasia interventions and participants appearing in recent systematic reviews of aphasia intervention effectiveness. The relationship between the quality of these descriptions and the robustness of research design is explored, and the replicability of aphasia interventions is evaluated.
Methods and Procedures : The scope of our search was an analysis of the aphasia intervention studies included in the and EBRSR 2018 systematic reviews, and in the RCSLT 2014 literature synthesis. Intervention descriptions published separately from the intervention study (i.e. published online, in clinical tools, or a separate trial protocols) were not included. The criteria for inclusion were that participants had aphasia, the intervention involved language and/or communication, and included the following research designs: Randomised Controlled Trial (RCT), comparison or control, crossover design, case series. Exclusion criteria included non-SLT interventions, studies involving fewer than four participants, conference abstracts, studies not available in English. Studies were evaluated for completeness of intervention description using the TIDieR Checklist. Additionally, we rated the quality of patient and intervention description, with particular reference to replicability.
Outcomes and Results: Ninety-three studies were included. Only 14 studies (15%) had >50 participants. Fifty-six studies (60%) did not select participants with a specific aphasia profile, and a further 10 studies only described participants as non-fluent. Across the studies, an average of eight (of 12) TIDieR checklist items were given but information on where, tailoring, modification and fidelity items was rarely available. Studies that evaluated general aphasia intervention approaches tended to use RCT designs, whereas more specific intervention studies were more likely to use case series designs.
Conclusions: Group studies were generally under-powered and there was a paucity of research looking at specific aphasia interventions for specific aphasia profiles. There was a trade-off between the robustness of the design and the level of specificity of the intervention described. While the TIDieR framework is a useful guide to information which should be included in an intervention study, it is insufficiently sensitive for assessing replicability. We consider possible solutions to the challenges of making large-scale trials more useful for determining effective aphasia intervention
Optimal and continuous anaemia control in a cohort of dialysis patients in Switzerland
BACKGROUND: Guidelines for the management of anaemia in patients with chronic kidney disease (CKD) recommend a minimal haemoglobin (Hb) target of 11 g/dL. Recent surveys indicate that this requirement is not met in many patients in Europe. In most studies, Hb is only assessed over a short-term period. The aim of this study was to examine the control of anaemia over a continuous long-term period in Switzerland. METHODS: A prospective multi-centre observational study was conducted in dialysed patients treated with recombinant human epoetin (EPO) beta, over a one-year follow-up period, with monthly assessments of anaemia parameters. RESULTS: Three hundred and fifty patients from 27 centres, representing 14% of the dialysis population in Switzerland, were included. Mean Hb was 11.9 +/- 1.0 g/dL, and remained stable over time. Eighty-five % of the patients achieved mean Hb >or= 11 g/dL. Mean EPO dose was 155 +/- 118 IU/kg/week, being delivered mostly by subcutaneous route (64-71%). Mean serum ferritin and transferrin saturation were 435 +/- 253 microg/L and 30 +/- 11%, respectively. At month 12, adequate iron stores were found in 72.5% of patients, whereas absolute and functional iron deficiencies were observed in only 5.1% and 17.8%, respectively. Multivariate analysis showed that diabetes unexpectedly influenced Hb towards higher levels (12.1 +/- 0.9 g/dL; p = 0.02). One year survival was significantly higher in patients with Hb >or= 11 g/dL than in those with Hb <11 g/dL (19.7% vs 7.3%, p = 0.006). CONCLUSION: In comparison to European studies of reference, this survey shows a remarkable and continuous control of anaemia in Swiss dialysis centres. These results were reached through moderately high EPO doses, mostly given subcutaneously, and careful iron therapy management
The prognosis of allocentric and egocentric neglect : evidence from clinical scans
We contrasted the neuroanatomical substrates of sub-acute and chronic visuospatial deficits associated with different aspects of unilateral neglect using computed tomography scans acquired as part of routine clinical diagnosis. Voxel-wise statistical analyses were conducted on a group of 160 stroke patients scanned at a sub-acute stage. Lesion-deficit relationships were assessed across the whole brain, separately for grey and white matter. We assessed lesions that were associated with behavioural performance (i) at a sub-acute stage (within 3 months of the stroke) and (ii) at a chronic stage (after 9 months post stroke). Allocentric and egocentric neglect symptoms at the sub-acute stage were associated with lesions to dissociated regions within the frontal lobe, amongst other regions. However the frontal lesions were not associated with neglect at the chronic stage. On the other hand, lesions in the angular gyrus were associated with persistent allocentric neglect. In contrast, lesions within the superior temporal gyrus extending into the supramarginal gyrus, as well as lesions within the basal ganglia and insula, were associated with persistent egocentric neglect. Damage within the temporo-parietal junction was associated with both types of neglect at the sub-acute stage and 9 months later. Furthermore, white matter disconnections resulting from damage along the superior longitudinal fasciculus were associated with both types of neglect and critically related to both sub-acute and chronic deficits. Finally, there was a significant difference in the lesion volume between patients who recovered from neglect and patients with chronic deficits. The findings presented provide evidence that (i) the lesion location and lesion size can be used to successfully predict the outcome of neglect based on clinical CT scans, (ii) lesion location alone can serve as a critical predictor for persistent neglect symptoms, (iii) wide spread lesions are associated with neglect symptoms at the sub-acute stage but only some of these are critical for predicting whether neglect will become a chronic disorder and (iv) the severity of behavioural symptoms can be a useful predictor of recovery in the absence of neuroimaging findings on clinical scans. We discuss the implications for understanding the symptoms of the neglect syndrome, the recovery of function and the use of clinical scans to predict outcome
Study of Z Boson Pair Production in e+e- Collisions at LEP at \sqrt{s}=189 GeV
The pair production of Z bosons is studied using the data collected by the L3
detector at LEP in 1998 in e+e- collisions at a centre-of-mass energy of 189
GeV. All the visible final states are considered and the cross section of this
process is measured to be 0.74 +0.15 -0.14 (stat.) +/- 0.04 (syst.) pb. Final
states containing b quarks are enhanced by a dedicated selection and their
production cross section is found to be 0.18 +0.09 -0.07 (stat.) +/- 0.02
(syst.) pb. Both results are in agreement with the Standard Model predictions.
Limits on anomalous couplings between neutral gauge bosons are derived from
these measurements
Search for Scalar Leptons in e+e- collisions at \sqrt{s}=189 GeV
We report the result of a search for scalar leptons in e+e- collisions at 189
GeV centre-of-mass energy at LEP. No evidence for such particles is found in a
data sample of 176 pb^{-1}. Improved upper limits are set on the production
cross sections for these new particles. New exclusion contours in the parameter
space of the Minimal Supersymmetric Standard Model are derived, as well as new
lower limits on the masses of these supersymmetric particles. Under the
assumptions of common gaugino and scalar masses at the GUT scale, we set an
absolute lower limit on the mass of the lightest scalar electron of 65.5 Ge
Formation of the in Two-Photon Collisions at LEP
The two-photon width of the meson has been
measured with the L3 detector at LEP. The is studied in the decay
modes , KK, KK,
KK, , , and
using an integrated luminosity of 140 pb at GeV and
of 52 pb at GeV. The result is
(BR) keV. The dependence of the cross section is studied for
GeV. It is found to be better described by a Vector Meson
Dominance model form factor with a J-pole than with a -pole. In addition,
a signal of events is observed at the mass. Upper limits
for the two-photon widths of the , , and are also
given
- …