313 research outputs found

    Variability of Insulin Requirements Over 12 Weeks of Closed-Loop Insulin Delivery in Adults With Type 1 Diabetes.

    Get PDF
    OBJECTIVE: To quantify variability of insulin requirements during closed-loop insulin delivery. RESEARCH DESIGN AND METHODS: We retrospectively analyzed overnight, daytime, and total daily insulin amounts delivered during a multicenter closed-loop trial involving 32 adults with type 1 diabetes. Participants applied hybrid day-and-night closed-loop insulin delivery under free-living home conditions over 12 weeks. The coefficient of variation was adopted to measure variability of insulin requirements in individual subjects. RESULTS: Data were analyzed from 1,918 nights, 1,883 daytime periods and 1,564 total days characterized by closed-loop use over 85% of time. Variability of overnight insulin requirements (mean [SD] coefficient of variation 31% [4]) was nearly twice as high as variability of total daily requirements (17% [3], P < 0.001) and was also higher than variability of daytime insulin requirements (22% [4], P < 0.001). CONCLUSIONS: Overnight insulin requirements were significantly more variable than daytime and total daily amounts. This may explain why some people with type 1 diabetes report frustrating variability in morning glycemia.Seventh Framework Programme of the European Union (ICT FP7- 247138). Additional support for the Artificial Pancreas work by JDRF, National Institute for Health Research Cambridge Biomedical Research Centre and Wellcome Strategic Award (100574/Z/12/Z). Abbott Diabetes Care supplied discounted continuous glucose monitoring devices, sensors, and communication protocol to facilitate real-time connectivity. We acknowledge support by the staff at the Addenbrooke’s Wellcome Trust Clinical Research Facility. Jasdip Mangat and John Lum (Jaeb Center) supported development and validation of the closed-loop system. Josephine Hayes (University of Cambridge) provided administrative support. Karen Whitehead (University of Cambridge) provided laboratory support. We acknowledge support by the staff at Profil Institut; Krisztina Schmitz-Grozs provided support as a research physician, Martina Haase supported the study as an insulin pump expert, and Maren Luebkert, Kirstin Kuschma and Elke Przetak provided administrative, coordinating and documentation support.This is the author accepted manuscript. The final version is available from the American Diabetes Association via http://dx.doi.org/10.2337/dc15-262

    Assessing the effectiveness of 3 months day and night home closed-loop insulin delivery in adults with suboptimally controlled type 1 diabetes: a randomised crossover study protocol.

    Get PDF
    INTRODUCTION: Despite therapeutic advances, many people with type 1 diabetes are still unable to achieve optimal glycaemic control, limited by the occurrence of hypoglycaemia. The objective of the present study is to determine the effectiveness of day and night home closed-loop over the medium term compared with sensor-augmented pump therapy in adults with type 1 diabetes and suboptimal glycaemic control. METHODS AND ANALYSIS: The study will adopt an open label, three-centre, multinational, randomised, two-period crossover study design comparing automated closed-loop glucose control with sensor augmented insulin pump therapy. The study will aim for 30 completed participants. Eligible participants will be adults (≥18 years) with type 1 diabetes treated with insulin pump therapy and suboptimal glycaemic control (glycated haemoglobin (HbA1c)≥7.5% (58 mmol/mmol) and ≤10% (86 mmol/mmol)). Following a 4-week optimisation period, participants will undergo a 3-month use of automated closed-loop insulin delivery and sensor-augmented pump therapy, with a 4-6 week washout period in between. The order of the interventions will be random. All analysis will be conducted on an intention to treat basis. The primary outcome is the time spent in the target glucose range from 3.9 to 10.0 mmol/L based on continuous glucose monitoring levels during the 3 months free living phase. Secondary outcomes include HbA1c changes; mean glucose and time spent above and below target glucose levels. Further, participants will be invited at baseline, midpoint and study end to participate in semistructured interviews and complete questionnaires to explore usability and acceptance of the technology, impact on quality of life and fear of hypoglycaemia. ETHICS AND DISSEMINATION: Ethical approval has been obtained at all sites. Before screening, all participants will be provided with oral and written information about the trial. The study will be disseminated by peer-review publications and conference presentations. TRIAL REGISTRATION NUMBER: NCT01961622 (ClinicalTrials.gov)

    Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study.

    Get PDF
    OBJECTIVE: To evaluate the feasibility of day and night closed-loop insulin delivery in adults with type 1 diabetes under free-living conditions. RESEARCH DESIGN AND METHODS: Seventeen adults with type 1 diabetes on insulin pump therapy (means ± SD age 34 ± 9 years, HbA1c 7.6 ± 0.8%, and duration of diabetes 19 ± 9 years) participated in an open-label multinational three-center crossover study. In a random order, participants underwent two 8-day periods (first day at the clinical research facility followed by 7 days at home) of sensor-augmented insulin pump therapy (SAP) or automated closed-loop insulin delivery. The primary end point was the time when sensor glucose was in target range between 3.9 and 10.0 mmol/L during the 7-day home phase. RESULTS: During the home phase, the percentage of time when glucose was in target range was significantly higher during closed-loop compared with SAP (median 75% [interquartile range 61-79] vs. 62% [53-70], P = 0.005). Mean glucose (8.1 vs. 8.8 mmol/L, P = 0.027) and time spent above target (P = 0.013) were lower during closed loop, while time spent below target was comparable (P = 0.339). Increased time in target was observed during both daytime (P = 0.017) and nighttime (P = 0.013). CONCLUSIONS: Compared with SAP, 1 week of closed-loop insulin delivery at home reduces mean glucose and increases time in target without increasing the risk of hypoglycemia in adults with relatively well-controlled type 1 diabetes.This is the author accepted manuscript. The final version can be found published here: http://care.diabetesjournals.org/content/37/7/1931.abstract

    Accuracy of Continuous Glucose Monitoring During Three Closed-Loop Home Studies Under Free-Living Conditions.

    Get PDF
    OBJECTIVES: Closed-loop (CL) systems modulate insulin delivery based on glucose levels measured by a continuous glucose monitor (CGM). Accuracy of the CGM affects CL performance and safety. We evaluated the accuracy of the Freestyle Navigator(®) II CGM (Abbott Diabetes Care, Alameda, CA) during three unsupervised, randomized, open-label, crossover home CL studies. MATERIALS AND METHODS: Paired CGM and capillary glucose values (10,597 pairs) were collected from 57 participants with type 1 diabetes (41 adults [mean±SD age, 39±12 years; mean±SD hemoglobin A1c, 7.9±0.8%] recruited at five centers and 16 adolescents [mean±SD age, 15.6±3.6 years; mean±SD hemoglobin A1c, 8.1±0.8%] recruited at two centers). Numerical accuracy was assessed by absolute relative difference (ARD) and International Organization for Standardization (ISO) 15197:2013 15/15% limits, and clinical accuracy was assessed by Clarke error grid analysis. RESULTS: Total duration of sensor use was 2,002 days (48,052 h). Overall sensor accuracy for the capillary glucose range (1.1-27.8 mmol/L) showed mean±SD and median (interquartile range) ARD of 14.2±15.5% and 10.0% (4.5%, 18.4%), respectively. Lowest mean ARD was observed in the hyperglycemic range (9.8±8.8%). Over 95% of pairs were in combined Clarke error grid Zones A and B (A, 80.1%, B, 16.2%). Overall, 70.0% of the sensor readings satisfied ISO criteria. Mean ARD was consistent (12.3%; 95% of the values fall within ±3.7%) and not different between participants (P=0.06) within the euglycemic and hyperglycemic range, when CL is actively modulating insulin delivery. CONCLUSIONS: Consistent accuracy of the CGM within the euglycemic-hyperglycemic range using the Freestyle Navigator II was observed and supports its use in home CL studies. Our results may contribute toward establishing normative CGM performance criteria for unsupervised home use of CL.Juvenile Diabetes Research Foundation (#22-2009-802), Diabetes UK (BDA07/0003549) and Seventh Framework Programme of the European Union (Grant Agreement number 247138) with additional support for the Artificial Pancreas work by National Institute of Diabetes and Digestive and Kidney Diseases (1R01DK085621), Wellcome Strategic Award (100574/Z/12/Z), and National Institute for Health Research Cambridge Biomedical Research Centre.This is the final version of the article. It first appeared from Mary Ann Liebert via http://dx.doi.org/10.1089/dia.2015.006

    Manejo de la defoliación y fertilización nitrogenada en pasto llorón, Eragrostis curvula, cv. Tanganyka : 1-rendimiento de materia seca, digestibilidad in vitro y rendimiento de materia seca digestible

    Get PDF
    p.7-14En una pradera de pasto llorón ubicada en Argerich se estudió el efecto de dos tratamientos de defoliación y tres niveles de fertilización nitrogenada durante tres ciclos consecutivos. El forraje se cortó con una frecuencia de 35 cm de altura o acumulado, hasta el 20 de febrero (primavera-verano), y sus rebrotes otoñales se cortaron en invierno (diferido). En primavera-verano el corte a 35 cm, produjo en promedio más materia seca que el acumulado y en el diferido a la inversa. Sus totales anuales fueron similares. La fertilización aumentó los rendimientos promedios parciales y totales (P menor a 0,05). La digestibiüdad primavera-estival fue mayor con cortes a 35 cm que en el acumulado y ambos tratamientos de defoliación respondieron al nitrógeno pero en sus diferidos el efecto fue de pequeña magnitud. Los rendimientos de materia seca digestible siguieron la misma tendencia que los de materia seca aunque, por influencia primavera-estival, en el total anual el corte a 35 cm superó al acumulado (P menor a 0,05). El rebrote primaveral sólo mostró un efecto residual parcial del fertilizante

    Bolusing frequency and amount impacts glucose control during hybrid closed-loop.

    Get PDF
    AIM: To compare bolus insulin delivery patterns during closed-loop home studies in adults with suboptimally [HbA1c 58-86 mmol/mol (7.5%-10%)] and well-controlled [58 mmol/mol (< 7.5%)] Type 1 diabetes. METHODS: Retrospective analysis of daytime and night-time insulin delivery during home use of closed-loop over 4 weeks. Daytime and night-time controller effort, defined as amount of insulin delivered by closed-loop relative to usual basal insulin delivery, and daytime bolus effort, defined as total bolus insulin delivery relative to total daytime insulin delivery were compared between both cohorts. Correlation analysis was performed between individual bolus behaviour (bolus effort and frequency) and daytime controller efforts, and proportion of time spent within and below sensor glucose target range. RESULTS: Individuals with suboptimally controlled Type 1 diabetes had significantly lower bolus effort (P = 0.038) and daily bolus frequency (P < 0.001) compared with those with well-controlled diabetes. Controller effort during both daytime (P = 0.007) and night-time (P = 0.005) were significantly higher for those with suboptimally controlled Type 1 diabetes. Time when glucose was within the target range (3.9-10.0 mmol/L) during daytime correlated positively with bolus effort (r = 0.37, P = 0.016) and bolus frequency (r = 0.33, P = 0.037). Time when glucose was below the target range during daytime was comparable in both groups (P = 0.36), and did not correlate significantly with bolus effort (r = 0.28, P = 0.066) or bolus frequency (r = -0.21, P = 0.19). CONCLUSION: More frequent bolusing and higher proportion of insulin delivered as bolus during hybrid closed-loop use correlated positively with time glucose was in target range. This emphasises the need for user input and educational support to benefit from this novel therapeutic modality.Seventh Framework Programme of the European Union (ICT FP7- 247138). Additional support for the Artificial Pancreas work by JDRF, National Institute for Health Research Cambridge Biomedical Research Centre, Wellcome Strategic Award (100574/Z/12/Z), EC Horizon 2020 (H2020-SC1-731560), NIDDK (DP3DK112176 and 1UC4DK108520-01), Efficacy and Mechanism Evaluation Programme of National Institute for Health Research (14/23/09) and Helmsley Trust (2016PG-T1D045 and #2016PG-T1D046)

    Behavioral Patterns and Associations with Glucose Control During 12-Week Randomized Free-Living Clinical Trial of Day and Night Hybrid Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes

    Get PDF
    Objectives\textbf{Objectives}: We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. Methods\textbf{Methods}: Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who underwent, in random order, 12 weeks free-living closed-loop (n = 32) and 12 weeks SAP (n = 33) periods. We quantified daily patterns of main meals, snacks, prandial insulin boluses, correction boluses, and fingerstick glucose measurements by analyzing data recorded on the study glucometer and on study insulin pump. Results\textbf{Results}: We analyzed 1942 closed-loop days and 2530 SAP days. The total number of insulin boluses was reduced during closed-loop versus SAP periods by mean 1.0 per day (95% confidence interval 0.6–1.4, P < 0.001) mainly because of a reduced number of correction boluses by mean 0.7 per day (0.4–1.0, P < 0.001). Other behavioral patterns were unchanged. The carbohydrate content of snacks but not the number of snacks was positively correlated with (1) glycemic variability as measured by standard deviation of sensor glucose (closed-loop P < 0.05; SAP P < 0.01), (2) mean sensor glucose (P < 0.05), and (3) postintervention HbA1c (P < 0.05). Behavioral patterns explained 47% of between-subject variance in glucose variability during SAP period and 30%–33% of variance of means sensor glucose and postintervention HbA1c. Conclusion\textbf{Conclusion}: Fewer correction boluses are delivered during closed-loop period. The size of snacks appears to worsen glucose control possibly because of carbohydrate-rich content of snacks. Modifiable behavioral patterns may be important determinants of glucose control.We acknowledge support by the staff at the Addenbrooke's Wellcome Trust Clinical Research Facility. Josephine Hayes (University of Cambridge) provided administrative support. Karen Whitehead (University of Cambridge) provided laboratory support. We acknowledge support by the staff at Profil Institut, Krisztina Schmitz-Grozs provided support as a research physician, Martina Haase supported the study as an insulin pump expert, and Maren Luebkert, Kirstin Kuschma, and Elke Przetak provided administrative, coordinating, and documentation support. Barbara Semlitsch and Markus Schauer (both from Medical University of Graz) supported the study as insulin pump experts. Funding was by Seventh Framework Programme of the European Union (ICT FP7-247138). Additional support for the Artificial Pancreas work was by JDRF, National Institute for Health Research Cambridge Biomedical Research Centre, Wellcome Strategic Award (100574/Z/12/Z), EC Horizon 2020 (H2020-SC1-731560), NIDDK (DP3DK112176 and 1UC4DK108520-01), Efficacy and Mechanism Evaluation Programme of National Institute for Health Research (14/23/09), and Helmsley Trust (Nos. 2016PG-T1D045 and 2016PG-T1D046). Abbott Diabetes Care supplied discounted continuous glucose monitoring devices, sensors, and communication protocol to facilitate real-time connectivity
    • …