11 research outputs found

    Assignment of glial brain tumors in humans by in vivo 1H-magnetic resonance spectroscopy and multidimensional metabolic classification

    Get PDF
    This study presents a simple approach for the noninvasive assignment of glial brain tumors according to malignancy by single-voxel proteon magnetic resonance spectroscopy at short echo times (TE≦50 milliseconds). Based on peak area ratios, a five-dimensional data set was obtained for each investigated subject. This vector was then projected along metabolic coordinates in a two-dimensional metabolic space. These coordinates had been determined in a previous study (Hagberg G et al., 1995,Magn Reson Med 34: 242-252). Tumor assignment was done without any knowledge of histology by comparing the location of the new cases to the features of the previous study. All 11 investigated glioblastomas multiforme, as well as 4 of 5 astrocytomas grade II, could easily be assigned to the groups of high- and low-grade tumors, respectively. Classification was more difficult in the case of a cystic astrocytoma grade II and one astrocytoma grade III. Two spectra measured in normal-appearing matter of glioblastoma patients were not classified as healthy. Using single-voxel proton magnetic resonance spectroscopy at short echo times with the knowledge of a base study, a straightforward, fast, and noninvasive differential diagnosis of glial brain tumors is possibl

    Mammotome: Less Invasive than ABBI with Similar Accuracy for Early Breast Cancer Detection

    Get PDF
    We performed a prospective analysis of two consecutive biopsy cohorts investigated by the same team to compare the Mammotome system with the ABBI procedure. From April 1997 to August 2003 a series of 413 nonpalpable mammographic lesions in 387 women (median age 56 years, range 30-84 years) were stereotactically biopsied in the University Hospital of Basel, Switzerland. Until October 1999 the ABBI system was applied exclusively, it was subsequently superseded by the Mammotome device in our clinic. Main outcome measures were accuracy, technical demand, and morbidity. Sensitivity (97.3%/96.8%), negative predictive value (99.2%/98.7%), and diagnostic accuracy (99.4%/99.1%) regarding the detection of malignancy were excellent for both techniques (ABBI/Mammotome). The Mammotome procedure was faster and less invasive, thus causing significantly less morbidity. The larger specimen obtained by the ABBI procedure resulted in more detailed histology. In conclusion, recommend the Mammotome system as the method of choice for detecting nonpalpable early breast cance

    Combined visual and motor evoked potentials predict multiple sclerosis disability after 20 years

    No full text
    The development of predictors of multiple sclerosis (MS) disability is difficult due to the complex interplay of pathophysiological and adaptive processes.; The purpose of this study was to investigate whether combined evoked potential (EP)-measures allow prediction of MS disability after 20 years.; We examined 28 patients with clinically definite MS according to Poser's criteria with Expanded Disability Status Scale (EDSS) scores, combined visual and motor EPs at entry (T0), 6 (T1), 12 (T2) and 24 (T3) months, and a cranial magnetic resonance imaging (MRI) scan at T0 and T2. EDSS testing was repeated at year 14 (T4) and year 20 (T5). Spearman rank correlation was used. We performed a multivariable regression analysis to examine predictive relationships of the sum of z-transformed EP latencies (s-EPT0) and other baseline variables with EDSST5.; We found that s-EPT0 correlated with EDSST5 (rho=0.72, p>0.0001) and ΔEDSST5-T0 (rho=0.50, p=0.006). Backward selection resulted in the prediction model: E (EDSST5)=3.91-2.22×therapy+0.079×age+0.057×s-EPT0 (Model 1, R (2)=0.58) with therapy as binary variable (1=any disease-modifying therapy between T3 and T5, 0=no therapy). Neither EDSST0 nor T2-lesion or gadolinium (Gd)-enhancing lesion quantities at T0 improved prediction of EDSST5. The area under the receiver operating characteristic (ROC) curve was 0.89 for model 1.; These results further support a role for combined EP-measures as predictors of long-term disability in MS

    Mammotome: less invasive than ABBI with similar accuracy for early breast cancer detection

    Full text link
    We performed a prospective analysis of two consecutive biopsy cohorts investigated by the same team to compare the Mammotome system with the ABBI procedure. From April 1997 to August 2003 a series of 413 nonpalpable mammographic lesions in 387 women (median age 56 years, range 30-84 years) were stereotactically biopsied in the University Hospital of Basel, Switzerland. Until October 1999 the ABBI system was applied exclusively, it was subsequently superseded by the Mammotome device in our clinic. Main outcome measures were accuracy, technical demand, and morbidity. Sensitivity (97.3%/96.8%), negative predictive value (99.2%/98.7%), and diagnostic accuracy (99.4%/99.1%) regarding the detection of malignancy were excellent for both techniques (ABBI/ Mammotome). The Mammotome procedure was faster and less invasive, thus causing significantly less morbidity. The larger specimen obtained by the ABBI procedure resulted in more detailed histology. In conclusion, recommend the Mammotome system as the method of choice for detecting nonpalpable early breast cancer

    Correction to: Second International Consensus Conference on lesions of uncertain malignant potential in the breast (B3 lesions).

    Get PDF
    The article Second International Consensus Conference on lesions of uncertain malignant potential in the breast (B3 lesions), written by Christoph J Rageth, Elizabeth AM O'Flynn, Katja Pinker, Rahel A Kubik-Huch, Alexander Mundinger, Thomas Decker, Christoph Tausch, Florian Dammann, Pascal A. Baltzer, Eva Maria Fallenberg, Maria P Foschini, Sophie Dellas, Michael Knauer, Caroline Malhaire, Martin Sonnenschein, Andreas Boos, Elisabeth Morris, Zsuzsanna Varga, was originally published electronically on the publisher's internet portal (currently SpringerLink) on November 30, 2018 without open access
    corecore