1,747 research outputs found
Development and Testing of a Methane/Oxygen Catalytic Microtube Ignition System for Rocket Propulsion
This study sought to develop a catalytic ignition advanced torch system with a unique catalyst microtube design that could serve as a low energy alternative or redundant system for the ignition of methane and oxygen rockets. Development and testing of iterations of hardware was carried out to create a system that could operate at altitude and produce a torch. A unique design was created that initiated ignition via the catalyst and then propagated into external staged ignition. This system was able to meet the goals of operating across a range of atmospheric and altitude conditions with power inputs on the order of 20 to 30 watts with chamber pressures and mass flow rates typical of comparable ignition systems for a 100 Ibf engine
Through-barrier electromagnetic imaging with an atomic magnetometer
We demonstrate the penetration of thick metallic and ferromagnetic barriers for imaging of conductive targets underneath. Our system is based on an 85Rb radio-frequency atomic magnetometer operating in electromagnetic induction imaging modality in an unshielded environment. Detrimental effects, including unpredictable magnetic signatures from ferromag- netic screens and variations in the magnetic background, are automatically compensated by active compensation coils controlled by servo loops. We exploit the tunability and low-frequency sensitivity of the atomic magnetometer to directly image multiple conductive targets concealed by a 2.5 mm ferromagnetic steel shield and/or a 2.0 mm aluminium shield, in a single scan. The performance of the atomic magnetometer allows imaging without any prior knowledge of the barriers or the targets, and without the need of background subtraction. A dedicated edge detection algorithm allows automatic estimation of the targets’ size within 3.3 mm and of their position within 2.4 mm. Our results prove the feasibility of a compact, sensitive and automated sensing platform for imaging of concealed objects in a range of applications, from security screening to search and rescue
Catalytic Microtube Rocket Igniter
Devices that generate both high energy and high temperature are required to ignite reliably the propellant mixtures in combustion chambers like those present in rockets and other combustion systems. This catalytic microtube rocket igniter generates these conditions with a small, catalysis-based torch. While traditional spark plug systems can require anywhere from 50 W to multiple kW of power in different applications, this system has demonstrated ignition at less than 25 W. Reactants are fed to the igniter from the same tanks that feed the reactants to the rest of the rocket or combustion system. While this specific igniter was originally designed for liquid methane and liquid oxygen rockets, it can be easily operated with gaseous propellants or modified for hydrogen use in commercial combustion devices. For the present cryogenic propellant rocket case, the main propellant tanks liquid oxygen and liquid methane, respectively are regulated and split into different systems for the individual stages of the rocket and igniter. As the catalyst requires a gas phase for reaction, either the stored boil-off of the tanks can be used directly or one stream each of fuel and oxidizer can go through a heat exchanger/vaporizer that turns the liquid propellants into a gaseous form. For commercial applications, where the reactants are stored as gases, the system is simplified. The resulting gas-phase streams of fuel and oxidizer are then further divided for the individual components of the igniter. One stream each of the fuel and oxidizer is introduced to a mixing bottle/apparatus where they are mixed to a fuel-rich composition with an O/F mass-based mixture ratio of under 1.0. This premixed flow then feeds into the catalytic microtube device. The total flow is on the order of 0.01 g/s. The microtube device is composed of a pair of sub-millimeter diameter platinum tubes connected only at the outlet so that the two outlet flows are parallel to each other. The tubes are each approximately 10 cm long and are heated via direct electric resistive heating. This heating brings the gasses to their minimum required ignition temperature, which is lower than the auto-thermal ignition temperature, and causes the onset of both surface and gas phase ignition producing hot temperatures and a highly reacting flame. The combustion products from the catalytic tubes, which are below the melting point of platinum, are injected into the center of another combustion stage, called the primary augmenter. The reactants for this combustion stage come from the same source but the flows of non-premixed methane and oxygen gas are split off to a secondary mixing apparatus and can be mixed in a near-stoichiometric to highly lean mixture ratio. The primary augmenter is a component that has channels venting this mixed gas to impinge on each other in the center of the augmenter, perpendicular to the flow from the catalyst. The total crosssectional area of these channels is on a similar order as that of the catalyst. The augmenter has internal channels that act as a manifold to distribute equally the gas to the inward-venting channels. This stage creates a stable flame kernel as its flows, which are on the order of 0.01 g/s, are ignited by the combustion products of the catalyst. This stage is designed to produce combustion products in the flame kernel that exceed the autothermal ignition temperature of oxygen and methane
Machine Learning Based Localization and Classification with Atomic Magnetometers
We demonstrate identification of position, material, orientation, and shape of objects imaged by a ⁸⁵Rb atomic magnetometer performing electromagnetic induction imaging supported by machine learning. Machine learning maximizes the information extracted from the images created by the magnetometer, demonstrating the use of hidden data. Localization 2.6 times better than the spatial resolution of the imaging system and successful classification up to 97% are obtained. This circumvents the need of solving the inverse problem and demonstrates the extension of machine learning to diffusive systems, such as low-frequency electrodynamics in media. Automated collection of task-relevant information from quantum-based electromagnetic imaging will have a relevant impact from biomedicine to security
Recommended Figures of Merit for Green Monopropellants
Hydrazine propellant has historically been used as a rocket thruster monopropellant since the mid-1960s. Mission managers are well aware of its characteristics and performance. However, it is a known toxic chemical and a wide effort is underway to reduce and/or eliminate its use worldwide. Several new propellant combinations have been developed in the last few years which tout or promise to provide same or better performance as hydrazine while being "non-toxic" or "green". Yet, there is no consistent definition for what constitutes "non-toxic" or "green", and thus no good figure of merit for which to compare. This paper seeks to review the three major categories of figures of merit, and discusses how they might be used to assess the viability of a propellant
Magnetic Induction Imaging with Optical Atomic Magnetometers: Towards Applications to Screening and Surveillance
We propose a new approach, based on optical atomic magnetometers and magnetic induction tomography (MIT), for remote and non-invasive detection of conductive targets. Atomic magnetometers overcome the main limitations of conventional MIT instrumentation, in particular their poor low-frequency sensitivity, their large size and their limited scalability. Moreover, atomic magnetometers have been proven to reach extremely high sensitivities, with an improvement of up to 7 orders of magnitude in the 50 MHz to DC band, with respect to a standard pick-up coil of the same size. In the present scheme, an oscillating magnetic field induces eddy currents in a conductive target and laser-pumped atomic magnetometers, either stand-alone or in an array, detect the response of the objects. A phase-sensitive detection scheme rejects the background, allowing remote detection of the secondary field and, thus, mapping of objects, hidden in cargos, underwater or underground. The potential for extreme sensitivity, miniaturization, dynamic range and array operation paves the way to a new generation of non-invasive, active detectors for surveillance, as well as for real-time cargo screening. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only
Survey Of UK Clinicians’ Approaches To Decision-Making In Neonatal Intestinal Failure
BACKGROUND: Outcomes for neonatal intestinal failure (IF) have improved significantly over the past two decades, however, there is no consensus for decision making among UK paediatric subspecialists. OBJECTIVES: The aim was to describe clinician’s attitudes to decision making in neonatal IF and examine variation between subspecialties. METHODS: Neonatologists, paediatric surgeons and gastroenterologists were surveyed electronically. They were asked if they would recommend active or palliative care or allow the parents to decide in several scenarios; or if they considered treatment morally obligatory or impermissible. RESULTS: Of 147 respondents, 81% of gastroenterologists would recommend active care (34.6% regardless of parental decision) for a term infant with total gut Hirschsprung’s compared with 46% and 33% of surgeons and neonatologists. No gastroenterologist would recommend palliation while 23% of both neonatologists and surgeons would. Similarly, 77% of surgeons and 73% of neonatologists would recommend palliation for a 28-week infant with IF and bilateral parenchymal haemorrhages compared with 27% of gastroenterologists. Prognostic estimates also varied. A term baby with IF was estimated to have a survival of >80% at 5 years by 58% of gastroenterologists compared with 11.5% and 2.7% of surgeons and neonatologists. Only 11.5% of surgeons and 2.6% of neonatologist believed a 26-week preterm with IF would have a 5-year survival >60% compared with 59% of gastroenterologists. CONCLUSION: There is substantial variation in views about outcomes and management choices both within and between specialties; with gastroenterologists being consistently more positive. This is likely to lead to unjustified variation in counselling and parental choices
- …