268 research outputs found

    Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation.</p> <p>Methods</p> <p>A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA), serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score), physician reported functional status and range of motion (Harris hip score), number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years).</p> <p>Discussion</p> <p>Superior results of large head metal-on-metal total hip arthroplasty over conventional hip arthroplasty have been put forward by experts, case series and the industry, but to our knowledge there is no randomized controlled evidence.</p> <p>Conclusion</p> <p>This randomized controlled study has been designed to test whether large head metal-on-metal cementless total hip arthroplasty leads to less periprosthetic bone density loss and higher serum metal ion concentrations compared to 28 mm metal-on-polyethylene cementless total hip arthroplasty.</p> <p>Trial registration</p> <p>Netherlands Trial Registry NTR1399</p

    The implications of 18F-FDG PET for the diagnosis of endoprosthetic loosening and infection in hip and knee arthroplasty: Results from a prospective, blinded study

    Get PDF
    BACKGROUND: The most frequent complications of joint arthroplasty are septic or aseptic loosening of endoprostheses. Preoperative differentiation is essential, since very different treatment methods result from the diagnoses. The aim of the current study was to evaluate the clinical value of (18)F-Fluoro-deoxyglucose positron emission tomography ((18)F-FDG PET) as a diagnostic modality for inflammation and loosening in hip and knee joint prostheses. METHODS: (18)F-FDG-PET examinations and multiphase bone scan were performed on hip and knee endoprostheses in 27 patients prior to revision surgical procedures planned for prosthetic loosening. Intact prostheses were found at the opposite site in some patients so that additional 9 joints could be examined with the field of view of (18)F-FDG PET. Verification and valuation of the PET and scintigraphic image findings were conducted by comparing them with information combined from intraoperative findings, histopathology, and microbiological investigations. RESULTS: Evidence of loosening was correctly determined in 76.4% of cases using (18)F-FDG-PET, and in 75% of cases using bone scan. The detection of periprosthetic inflammation using (18)F-FDG-PET had a sensitivity of 100% for septic cases and of 45.5% in cases of increased abrasion and aseptic foreign-body reactions. However, reliable differentiation between abrasion-induced and bacterial-caused inflammation was not possible using (18)F-FDG-PET. CONCLUSION: (18)F-Fluoro-deoxyglucose positron emission tomography ((18)F-FDG-PET) allows reliable prediction of peri-prosthetic septical inflammatory tissue reactions. Because of the high sensitivity of this method, a negative PET result in the setting of a diagnostically unclear situation eliminates the need for revision surgery. In contrast, a positive PET result gives no clear differentiation regarding the cause of inflammation

    The Elite-Plus stem migrates more than the flanged Charnley stem: A clinical, radiographic, and radiostereometric analysis of 114 patients with an average of 7 years follow-up

    Get PDF
    Background and purpose The Charnley Elite-Plus stem was introduced in 1993 as a presumed improvement of the flanged Charnley stem. We started this study in 1996 to investigate the migratory pattern of the Elite-Plus stem. Patients and methods We followed 114 patients with osteoarthritis and a primary total hip replacement with the Elite-Plus stem. Mean age at the time of operation was 64 (50-76) years. The mean follow-up time was 6.5 (2-7) years. Radiographs were evaluated with respect to cementing technique, migration, and wear measured by radiostereometry (RSA). Results The stem survival was 98% (CI: 96-100) at 7 years and 92% (CI: 86-97) at 10 years. Mean migration of the femoral head was 0.35 mm (SD 0.3) medially, 0.51 mm (SD 0.6) distally, and 1.1 mm (SD 1.8) in the dorsal direction. Mean total point motion was 1.7 mm (SD 1.7). The migration of the stems stabilized after 5 years in the medial and dorsal directions, but continued to subside slightly. Migration along any of the axes was higher if the cementing technique was inferior. Interpretation Patients with a Charnley Elite-Plus stem and defects in the cement mantle or other signs of inferior implantation technique should be carefully monitored

    A modified cementing technique using BoneSource to augment fixation of the acetabulum in a sheep model

    Get PDF
    Background and purpose Our aim was to prove in an animal model that the use of HA paste at the cement-bone interface in the acetabulum would improve fixation. We examined, in sheep, the effect of interposing a layer of hydroxyapatite cement around the periphery of a polyethylene socket prior to fixing it using polymethylemethacrylate (PMMA). Methods We made a randomized study involving 22 sheep to test whether the application of BoneSource hydroxyapatite material to the surface of the ovine acetabulum prior to cementing a polyethylene cup at hip arthroplasty improved the fixation and the nature of the interface. We studied the gross radiographical appearance of the implant-bone interface and the histological appearance at the interface. Results There were more radiolucencies evident in the control group. Histologically, only sheep randomized into the BoneSource group exhibited a fully osseointegrated interface. Use of the hydroxyapatite material did not confer any detrimental effects. In some cases the material appeared to have been fully resorbed. When the material was evident on histological section, it was incorporated into an osseointegrated interface. There was no giant cell reaction present in any case. There was no evidence of migration of BoneSource to the articulation. Interpretation The application of HA material prior to cementation of a socket produced an improved interface. The technique may be useful in man with to extend the longevity of the cemented implant by protecting the socket interface from the effect of hydrodynamic fluid flow and particulate debris

    Alumina-on-alumina total hip replacement for femoral neck fracture in healthy patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Total hip replacement is considered the best option for treatment of displaced intracapsular fractures of the femoral neck (FFN). The size of the femoral head is an important factor that influences the outcome of a total hip arthroplasty (THA): implants with a 28 mm femoral head are more prone to dislocate than implants with a 32 mm head. Obviously, a large head coupled to a polyethylene inlay can lead to more wear, osteolysis and failure of the implant. Ceramic induces less friction and minimal wear even with larger heads.</p> <p>Methods</p> <p>A total of 35 THAs were performed for displaced intracapsular FFN, using a 32 mm alumina-alumina coupling.</p> <p>Results</p> <p>At a mean follow-up of 80 months, 33 have been clinically and radiologically reviewed. None of the implants needed revision for any reason, none of the cups were considered to have failed, no dislocations nor breakage of the ceramic components were recorded. One anatomic cementless stem was radiologically loose.</p> <p>Conclusions</p> <p>On the basis of our experience, we suggest that ceramic-on-ceramic coupling offers minimal friction and wear even with large heads.</p
    corecore