25,885 research outputs found

    Strong coupling expansion of chiral models

    Full text link
    A general precedure is outlined for an algorithmic implementation of the strong coupling expansion of lattice chiral models on arbitrary lattices. A symbolic character expansion in terms of connected values of group integrals on skeleton diagrams may be obtained by a fully computerized approach.Comment: 2 pages, PostScript file, contribution to conference LATTICE '9

    Wearable wireless tactile display for virtual interactions with soft bodies.

    Get PDF
    We describe here a wearable, wireless, compact, and lightweight tactile display, able to mechanically stimulate the fingertip of users, so as to simulate contact with soft bodies in virtual environments. The device was based on dielectric elastomer actuators, as high-performance electromechanically active polymers. The actuator was arranged at the user's fingertip, integrated within a plastic case, which also hosted a compact high-voltage circuitry. A custom-made wireless control unit was arranged on the forearm and connected to the display via low-voltage leads. We present the structure of the device and a characterization of it, in terms of electromechanical response and stress relaxation. Furthermore, we present results of a psychophysical test aimed at assessing the ability of the system to generate different levels of force that can be perceived by users.The authors gratefully acknowledge financial support from COST – European Cooperation in Science and Technology, within the framework of “ESNAM – European Scientific Network for Artificial Muscles” (COST Action MP1003). Gabriele Frediani also acknowledges support from the European Commission, within the framework of the project “CEEDS: The Collective Experience of Empathic Data Systems” (FP7-ICT-2009.8.4, Grant 258749) and “Fondazione Cassa di Risparmio di Pisa,” within the framework of the project “POLOPTEL” (Grant 167/09

    Analysis of some recharge solutions on varying the R407C composition

    Get PDF
    In the vapour compression plants possible leaks can vary the composition of a zeotropic refrigerant mixture. The main aim of this paper is to verify experimentally if the plant performances are restored with a proper recharge, when leaks are imposed. As for the R407C mixture the percentage of the less volatile component (R134a) increases, while the percentage of the more volatile components (R32 and R125) decreases when leaks occur. The experimental tests have been realized determining refrigerant leaks from the liquid receiver placed at the condenser outlet and measuring the properties in steady state condition. The recharge is realized in different ways: with R407C, with R134a and R410A or with R32 R125 and R134a. The different solutions are then compared from the economical point of view, in terms of COP, refrigeration power and air temperature at the evaporator outlet, adopting an iteration method. This method determines the real composition of a zeotropic mixture working in a compression plant, when only the temperature and pressure values at the expansion valve inlet and outlet are known

    Intrinsic electric field effects on few-particle interactions in coupled GaN quantum dots

    Get PDF
    We study the multi-exciton optical spectrum of vertically coupled GaN/AlN quantum dots with a realistic three-dimensional direct-diagonalization approach for the description of few-particle Coulomb-correlated states. We present a detailed analysis of the fundamental properties of few-particle/exciton interactions peculiar of nitride materials. The giant intrinsic electric fields and the high electron/hole effective masses give rise to different effects compared to GaAs-based quantum dots: intrinsic exciton-exciton coupling, non-molecular character of coupled dot exciton wavefunction, strong dependence of the oscillator strength on the dot height, large ground state energy shift for dots separated by different barriers. Some of these effects make GaN/AlN quantum dots interesting candidates in quantum information processing.Comment: 23 pages, 8 figures, 1 tabl

    Alternativas para o manejo de lebres em pomares de citros.

    Get PDF
    bitstream/item/31083/1/COMUNICADO-135.pd

    Low delta-V near-Earth asteroids: A survey of suitable targets for space missions

    Full text link
    In the last decades Near-Earth Objects (NEOs) have become very important targets to study, since they can give us clues to the formation, evolution and composition of the Solar System. In addition, they may represent either a threat to humankind, or a repository of extraterrestrial resources for suitable space-borne missions. Within this framework, the choice of next-generation mission targets and the characterisation of a potential threat to our planet deserve special attention. To date, only a small part of the 11,000 discovered NEOs have been physically characterised. From ground and space-based observations one can determine some basic physical properties of these objects using visible and infrared spectroscopy. We present data for 13 objects observed with different telescopes around the world (NASA-IRTF, ESO-NTT, TNG) in the 0.4 - 2.5 um spectral range, within the NEOSURFACE survey (http://www.oa-roma.inaf.it/planet/NEOSurface.html). Objects are chosen from among the more accessible for a rendez-vous mission. All of them are characterised by a delta-V (the change in velocity needed for transferring a spacecraft from low-Earth orbit to rendez-vous with NEOs) lower than 10.5 km/s, well below the Solar System escape velocity (12.3 km/s). We taxonomically classify 9 of these objects for the first time. 11 objects belong to the S-complex taxonomy; the other 2 belong to the C-complex. We constrain the surface composition of these objects by comparing their spectra with meteorites from the RELAB database. We also compute olivine and pyroxene mineralogy for asteroids with a clear evidence of pyroxene bands. Mineralogy confirms the similarity with the already found H, L or LL ordinary chondrite analogues.Comment: 9 pages, 7 figures, to be published in A&A Minor changes by language edito

    Refrigeration plant exergetic analysis varying the compressor capacity

    Get PDF
    The paper presents an exergetic analysis of a vapour compressor refrigeration plant when the refrigeration capacity is controlled by varying the compressor speed. The aim is performance evaluation of both the whole plant and its individual components. The analysis of the exergy flow destroyed in each device of the plant varying the compressor speed has been carried out in order to determine the relative irreversibility of the plant components. The vapour compression plant is subjected to a commercially available cold store. The compressor working with R22, R407C and R507 and designed for a revolution speed corresponding to 50 Hz supply current frequency, has been used varying the frequency in the range 30–50 Hz. In this range, the most suitable working fluids proposed as substitutes of R22, as R407C (R32/R125/R134a 23/25/52% in mass), R507 (R125/R143A 50/50% in mass) and R417A (R125/R134a/R600 46.6/50/3.4% in mass), have been tested. The variable-speed compressor is fitted with a pulse-width modulated source inverter (PWM) predominantly used in medium power applications due to its relatively low cost and high efficiency. The basic difference between variable speed refrigeration and conventional refrigeration systems is in the control of the system capacity at part-load conditions. The conventional refrigeration systems are characterized by compressor on/off cycles arising from by the thermostatic control. On the contrary when the inverter is used the capacity of the refrigeration system is matched to the load regulating the compressor motor speed. When the control of the compressor capacity is obtained by varying its speed there is an energy saving with respect to the thermostatic control. The best results of the exergetic analysis have been obtained using R22 followed by the non-azeotropic mixture designed as R407C that confirms, among the fluid candidates R22 substitution a better performance, shown also at the compressor nominal speed. Copyright © 2003 John Wiley & Sons, Ltd

    Refrigeration plant exergetic analysis varying the compressor capacity

    Get PDF
    The paper presents an exergetic analysis of a vapour compressor refrigeration plant when the refrigeration capacity is controlled by varying the compressor speed. The aim is performance evaluation of both the whole plant and its individual components. The analysis of the exergy flow destroyed in each device of the plant varying the compressor speed has been carried out in order to determine the relative irreversibility of the plant components. The vapour compression plant is subjected to a commercially available cold store. The compressor working with R22, R407C and R507 and designed for a revolution speed corresponding to 50 Hz supply current frequency, has been used varying the frequency in the range 30–50 Hz. In this range, the most suitable working fluids proposed as substitutes of R22, as R407C (R32/R125/R134a 23/25/52% in mass), R507 (R125/R143A 50/50% in mass) and R417A (R125/R134a/R600 46.6/50/3.4% in mass), have been tested. The variable-speed compressor is fitted with a pulse-width modulated source inverter (PWM) predominantly used in medium power applications due to its relatively low cost and high efficiency. The basic difference between variable speed refrigeration and conventional refrigeration systems is in the control of the system capacity at part-load conditions. The conventional refrigeration systems are characterized by compressor on/off cycles arising from by the thermostatic control. On the contrary when the inverter is used the capacity of the refrigeration system is matched to the load regulating the compressor motor speed. When the control of the compressor capacity is obtained by varying its speed there is an energy saving with respect to the thermostatic control. The best results of the exergetic analysis have been obtained using R22 followed by the non-azeotropic mixture designed as R407C that confirms, among the fluid candidates R22 substitution a better performance, shown also at the compressor nominal speed
    • …
    corecore