222 research outputs found

    Developments of the pinned photodiode terahertz rectifier

    Get PDF
    This paper presents we presents a development of the structure of the pinned photodiode terahertz rectifier, in which the metal whisker of the antenna is separated from the semiconductor by a silane oxide layer, in order to reduce the surface defectiveness. The rectifies is the basic component of an image detection system based on the structure of actual CMOS image detectors. The structure combines a nano-antenna, fabricated on the top of a standard image sensor, the rectifier, and the readout electronics. The rectifier device proposed has vertical extension of some tenths of nanometers, can be created at the foot of the nano-whisker at the end of the terahertz antenna, above the storage well

    The face of Glut1-DS patients : A 3D craniofacial morphometric analysis

    Get PDF
    Introduction - Glut1 deficiency syndrome (Glut1-DS) is a neurological and metabolic disorder caused by impaired transport of glucose across the blood brain barrier (BBB). Mutations on the SCL2A1 gene encoding the glucose transporter protein in the BBB cause the syndrome, which encompasses epilepsy, movement disorders and mental delay. Such variability of symptoms presents an obstacle to early diagnosis. The patients seem to share some craniofacial features, and identification and quantification of these could help in prompt diagnosis and clinical management. Materials and method - We performed a three-dimensional morphometric analysis of the faces of 11 female Glut1-DS patients using a stereophotogrammetric system. Data were analyzed using both inter-landmark distances and Principal Component Analysis (PCA). Results - Compared to data collected from age-, sex- and ethnicity-matched control subjects, common and homogenous facial features were identified among patients, which were mainly located in the mandible and the eyes. Glut1-DS patients had a more anterior chin; their mandibular body was longer but the rami were shorter, with a reduced gonial angle; they had smaller and down-slanted eyes with a reduced intercanthal distance. Conclusions - This study highlights the importance of morphometric analysis for defining the facial anatomical characteristics of the syndrome better, potentially helping clinicians to diagnose Glut1-DS. Imnproved knowledge of the facial anatomy of these patients can provide insights into their facial and cerebral embryological development, perhaps further clarifying the molecular basis of the syndrome

    Laparoscopic Ovariectomy in Standing Mule Mares

    Get PDF
    Mules are hybrids bred from the mating of a jack donkey and a horse mare, known for their strength and resistance and still used to work in agriculture. Although they have been for long considered sterile, evidence of estrus cycle has been demonstrated together with abnormal behavior related to ovarian activity. In this study, a bilateral standing laparoscopic ovariectomy technique using the LigaSure technology was applied in 10 mare mules for treating unwanted behavioral patterns. The technique was effectively performed on these animals avoiding the risk of general anesthesia, and the use of the LigaSure technology allowed good hemostasis and reduced surgical time. Owners declared to be satisfied with the resolution of the behavior

    Natural Occurrence of Ochratoxin A in Blood and Milk Samples from Jennies and Their Foals after Delivery

    Get PDF
    An assessment of the natural ochratoxin A (OTA) exposure of seven Martina Franca jennies was carried out by analyzing blood and milk samples collected close to and after delivery. A total of 41 and 34 blood samples were collected from jennies and foals, respectively, and analyzed by ELISA. A total of 33 milk samples were collected from jennies and analyzed by the HPLC/FLD method based on IAC clean-up. Furthermore, 53 feed samples were collected from January to September and analyzed by a reference method (AOAC Official Method No. 2000.03) for OTA content. Feed samples showed OTA levels up to 2.7 ng/g with an incidence of 32%, while the OTA incidence rate in jennies' blood samples was 73%, with a median value of 97 ng/L and concentrations ranging fro

    External Validation of Equations to Estimate Resting Energy Expenditure in 2037 Children and Adolescents with and 389 without Obesity : a Cross-Sectional Study

    Get PDF
    We performed an external cross-validation study of 10 equations to estimate resting energy expenditure (REE) in 2037 children with and 389 without obesity. Inclusion criteria were Caucasian ethnicity, age 64 18 years, and availability of REE. REE was measured using indirect calorimetry. The correct classification fraction (CCF) of an equation was defined as the fraction of subjects whose estimated REE was within 10% of measured REE. The Moln\ue1r equation was the most accurate REE prediction equation with CCFs of 0.70 (95% CI 0.65 to 0.76) in girls without obesity, 0.64 (95% CI 0.61 to 0.66) in girls with obesity, 0.76 (95% CI 0.67 to 0.83) in boys without obesity, and 0.66 (95% CI 0.63 to 0.69) in boys with obesity. The Mifflin equation was the second most accurate equation with CCFs of 0.67 (95% CI 0.61 to 0.73) in girls without obesity, 0.61 (95% CI 0.58 to 0.64) in girls with obesity, 0.75 (95% CI 0.66 to 0.82) in boys without obesity, and 0.66 (95% CI 0.63 to 0.69) in boys with obesity

    Collet-Sicard syndrome mimicking neuralgic amyotrophy

    Full text link
    A man with shoulder pain, wasting, and weakness had ipsilateral cranial nerve abnormalities. Electrodiagnostic studies supported a diagnosis of neuralgic amyotrophy, but we later demonstrated a spinal accessory mononeuropathy with ipsilateral hypoglossal weakness (Collet-Sicard syndrome). Magnetic resonance imaging demonstrated an inaccessible occipital condyle mass, and disseminated adenocarcinoma was subsequently diagnosed. Although cranial mononeuropathies can occur in neuralgic amyotrophy, this case illustrates the importance of identifying a focal lesion, and highlights the localizing value of electrodiagnosis. © 1997 John Wiley & Sons, Inc. Muscle Nerve 20:1173–1177, 1997Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/34626/1/13_ftp.pd

    Myalgia, Obtundity and Fever in a Patient with a Prosthesis

    Get PDF
    Objective: We describe a rare case of group G streptococcus (GGS) sepsis complicated by bacterial toxin myopathy. Case: A 65-year-old man, with a history of infection of his shoulder prosthesis, presented with multiorgan failure and notable myalgia likely caused by toxins. The patient was treated successfully with antibiotics and prosthesis removal. Conclusion: This case suggests infection by GGS should be considered in a patient presenting with myalgia associated with sepsis

    Comparison of established and emerging biodosimetry assays

    Get PDF
    Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3-0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5-4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools
    • …
    corecore