1,435 research outputs found

    Tunable Optical Filters for Space Exploration

    Get PDF
    Spectrally tunable liquid crystal filters provide numerous advantages and several challenges in space applications. We discuss the tradeoffs in design elements for tunable liquid crystal birefringent filters with special consideration required for space exploration applications. In this paper we present a summary of our development of tunable filters for NASA space exploration. In particular we discuss the application of tunable liquid crystals in guidance navigation and control in space exploration programs. We present a summary of design considerations for improving speed, field of view, transmission of liquid crystal tunable filters for space exploration. In conclusion, the current state of the art of several NASA LaRC assembled filters is presented and their performance compared to the predicted spectra using our PolarTools modeling software

    An Abbreviated NAGPRA Inventory of the North Carolina Archaeological Collection

    Get PDF
    The Research Laboratories of Archaeology's inventory of human skeletal remains and associated and unassociated funerary objects from Native American sites in the North Carolina Archaeological Collection at the University of North Carolina at Chapel Hill

    An Integrative Review of Physical Activity in Adults with Inflammatory Bowel Disease

    Get PDF
    Adults with inflammatory bowel disease (IBD) search for self-management strategies to manage their symptoms and improve their quality of life (QOL). Physical activity (PA) is one of the self-management strategies widely adopted by adults with IBD. This integrative review aimed to synthesize the evidence on health outcomes of PA in adults with IBD as well as to identify the barriers to engaging in PA. Using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), published literature was searched to identify the articles that addressed PA in adults with IBD. Twenty-eight articles met the inclusion criteria. Many of the reviewed studies used the terms of PA and exercise interchangeably. Walking was the most common PA reported in the studies. The findings from the majority of the reviewed studies supported the benefits of moderate-intensity exercise/PA among adults with IBD. The reviewed studies noted the following positive health outcomes of PA: improvement in QOL, mental health, sleep quality, gastrointestinal symptoms, fatigue and cardiorespiratory fitness. More importantly, participation in PA reduced the risk for development of IBD and the risk for future active disease. The findings from the reviewed studies highlighted the following barriers to engage in PA: fatigue, joint pain, abdominal pain, bowel urgency, active disease and depression

    Stabilized tin-oxide-based oxidation/reduction catalysts

    Get PDF
    The invention described herein involves a novel approach to the production of oxidation/reduction catalytic systems. The present invention serves to stabilize the tin oxide reducible metal-oxide coating by co-incorporating at least another metal-oxide species, such as zirconium. In one embodiment, a third metal-oxide species is incorporated, selected from the group consisting of cerium, lanthanum, hafnium, and ruthenium. The incorporation of the additional metal oxide components serves to stabilize the active tin-oxide layer in the catalytic process during high-temperature operation in a reducing environment (e.g., automobile exhaust). Moreover, the additional metal oxides are active components due to their oxygen-retention capabilities. Together, these features provide a mechanism to extend the range of operation of the tin-oxide-based catalyst system for automotive applications, while maintaining the existing advantages

    Methodology for the effective stabilization of tin-oxide-based oxidation/reduction catalysts

    Get PDF
    The invention described herein involves a novel approach to the production of oxidation/reduction catalytic systems. The present invention serves to stabilize the tin oxide reducible metal-oxide coating by co-incorporating at least another metal-oxide species, such as zirconium. In one embodiment, a third metal-oxide species is incorporated, selected from the group consisting of cerium, lanthanum, hafnium, and ruthenium. The incorporation of the additional metal oxide components serves to stabilize the active tin-oxide layer in the catalytic process during high-temperature operation in a reducing environment (e.g., automobile exhaust). Moreover, the additional metal oxides are active components due to their oxygen-retention capabilities. Together, these features provide a mechanism to extend the range of operation of the tin-oxide-based catalyst system for automotive applications, while maintaining the existing advantages

    Tissue Effects in a Randomized Controlled Trial of Short-term Finasteride in Early Prostate Cancer.

    Get PDF
    BackgroundIn the Prostate Cancer Prevention Trial, finasteride selectively suppressed low-grade prostate cancer and significantly reduced the incidence of prostate cancer in men treated with finasteride compared with placebo. However, an apparent increase in high-grade disease was also observed among men randomized to finasteride. We aimed to determine why and hypothesized that there is a grade-dependent response to finasteride.MethodsFrom 2007 to 2012, we randomized dynamically by intranet-accessible software 183 men with localized prostate cancer to receive 5mg finasteride or placebo daily in a double-blind study during the 4-6weeks preceding prostatectomy. As the primary end point, the expression of a predefined molecular signature (ERβ, UBE2C, SRD5A2, and VEGF) differentiating high- and low-grade tumors in Gleason grade (GG) 3 areas of finasteride-exposed tumors from those in GG3 areas of placebo-exposed tumors, adjusted for Gleason score (GS) at prostatectomy, was compared. We also determined androgen receptor (AR) levels, Ki-67, and cleaved caspase 3 to evaluate the effects of finasteride on the expression of its downstream target, cell proliferation, and apoptosis, respectively. The expression of these markers was also compared across grades between and within treatment groups. Logistic regression was used to assess the expression of markers.FindingsWe found that the predetermined molecular signature did not distinguish GG3 from GG4 areas in the placebo group. However, AR expression was significantly lower in the GG4 areas of the finasteride group than in those of the placebo group. Within the finasteride group, AR expression was also lower in GG4 than in GG3 areas, but not significantly. Expression of cleaved caspase 3 was significantly increased in both GG3 and GG4 areas in the finasteride group compared to the placebo group, although it was lower in GG4 than in GG3 areas in both groups.InterpretationWe showed that finasteride's effect on apoptosis and AR expression is tumor grade dependent after short-term intervention. This may explain finasteride's selective suppression of low-grade tumors observed in the PCPT

    Self-Assessed Competency at Working with a Medical Interpreter Is Not Associated with Knowledge of Good Practice

    Get PDF
    BACKGROUND: Specific knowledge and skills are needed to work effectively with an interpreter, but most doctors have received limited training. Self-assessed competency may not accurately identify training needs. PURPOSES: The purpose of this study is to explore the association between self-assessed competency at working with an interpreter and the ability to identify elements of good practice, using a written vignette. METHODS: A mailed questionnaire was sent to 619 doctors and medical students in Geneva, Switzerland. RESULTS: 58.6% of respondents considered themselves to be highly competent at working with a professional interpreter, but 22% failed to mention even one element of good practice in response to the vignette, and only 39% could name more than one. There was no association between self-rated competency and number of elements mentioned. CONCLUSIONS: Training efforts should challenge the assumption that working with an interpreter is intuitive. Evaluation of clinicians' ability to work with an interpreter should not be limited to self-ratings. In the context of large-scale surveys, written vignettes may provide a simple method for identifying knowledge of good practice and topics requiring further training
    • …
    corecore