2,241 research outputs found
Precision frequency measurements with interferometric weak values
We demonstrate an experiment which utilizes a Sagnac interferometer to
measure a change in optical frequency of 129 kHz per root Hz with only 2 mW of
continuous wave, single mode input power. We describe the measurement of a weak
value and show how even higher frequency sensitivities may be obtained over a
bandwidth of several nanometers. This technique has many possible applications,
such as precision relative frequency measurements and laser locking without the
use of atomic lines.Comment: 4 pages, 3 figures, published in PR
Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification
We report on the use of an interferometric weak value technique to amplify
very small transverse deflections of an optical beam. By entangling the beam's
transverse degrees of freedom with the which-path states of a Sagnac
interferometer, it is possible to realize an optical amplifier for polarization
independent deflections. The theory for the interferometric weak value
amplification method is presented along with the experimental results, which
are in good agreement. Of particular interest, we measured the angular
deflection of a mirror down to 560 femtoradians and the linear travel of a
piezo actuator down to 20 femtometers
Optimizing the Signal to Noise Ratio of a Beam Deflection Measurement with Interferometric Weak Values
The amplification obtained using weak values is quantified through a detailed
investigation of the signal to noise ratio for an optical beam deflection
measurement. We show that for a given deflection, input power and beam radius,
the use of interferometric weak values allows one to obtain the optimum signal
to noise ratio using a coherent beam. This method has the advantage of reduced
technical noise and allows for the use of detectors with a low saturation
intensity. We report on an experiment which improves the signal to noise ratio
for a beam deflection measurement by a factor of 54 when compared to a
measurement using the same beam size and a quantum limited detector
Continuous phase amplification with a Sagnac interferometer
We describe a weak value inspired phase amplification technique in a Sagnac
interferometer. We monitor the relative phase between two paths of a slightly
misaligned interferometer by measuring the average position of a split-Gaussian
mode in the dark port. Although we monitor only the dark port, we show that the
signal varies linearly with phase and that we can obtain similar sensitivity to
balanced homodyne detection. We derive the source of the amplification both
with classical wave optics and as an inverse weak value.Comment: 5 pages, 4 figures, previously submitted for publicatio
Microbial ecology of Thiobacillus ferrooxidans
FINAL TECHNICAL REPORT
TO
U.S. DEPARTMENT OF THE INTERIOR
Geological Survey
Washington. D.C.The contents of this report were developed in part under a grant from
the Department of the Interior, U.S. Geological Survey. Grant number 14-08-0001-61313
Interferometric weak value deflections: quantum and classical treatments
We derive the weak value deflection given in a paper by Dixon et al. (Phys.
Rev. Lett. 102, 173601 (2009)) both quantum mechanically and classically. This
paper is meant to cover some of the mathematical details omitted in that paper
owing to space constraints
Recommended from our members
Identification of candidate genes affecting Delta9-tetrahydrocannabinol biosynthesis in Cannabis sativa.
RNA isolated from the glands of a Delta(9)-tetrahydrocannabinolic acid (THCA)-producing strain of Cannabis sativa was used to generate a cDNA library containing over 100 000 expressed sequence tags (ESTs). Sequencing of over 2000 clones from the library resulted in the identification of over 1000 unigenes. Candidate genes for almost every step in the biochemical pathways leading from primary metabolites to THCA were identified. Quantitative PCR analysis suggested that many of the pathway genes are preferentially expressed in the glands. Hexanoyl-CoA, one of the metabolites required for THCA synthesis, could be made via either de novo fatty acids synthesis or via the breakdown of existing lipids. qPCR analysis supported the de novo pathway. Many of the ESTs encode transcription factors and two putative MYB genes were identified that were preferentially expressed in glands. Given the similarity of the Cannabis MYB genes to those in other species with known functions, these Cannabis MYBs may play roles in regulating gland development and THCA synthesis. Three candidates for the polyketide synthase (PKS) gene responsible for the first committed step in the pathway to THCA were characterized in more detail. One of these was identical to a previously reported chalcone synthase (CHS) and was found to have CHS activity. All three could use malonyl-CoA and hexanoyl-CoA as substrates, including the CHS, but reaction conditions were not identified that allowed for the production of olivetolic acid (the proposed product of the PKS activity needed for THCA synthesis). One of the PKS candidates was highly and specifically expressed in glands (relative to whole leaves) and, on the basis of these expression data, it is proposed to be the most likely PKS responsible for olivetolic acid synthesis in Cannabis glands
Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification
We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam’s transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 40
Precision Frequency Measurements with Interferometric Weak Values
We demonstrate an experiment which utilizes a Sagnac interferometer to measure a change in optical frequency of 129 ± 7 kHz/√Hz with only 2 mW of continuous-wave, single-mode input power. We describe the measurement of a weak value and show how even higher-frequency sensitivities may be obtained over a bandwidth of several nanometers. This technique has many possible applications, such as precision relative frequency measurements and laser locking without the use of atomic lines
- …