2,404 research outputs found

    Numerical Modeling Of Hohlraum Radiation Conditions: Spatial And Spectral Variations Due To Sample Position, Beam Pointing, And Hohlraum Geometry

    Get PDF
    View-factor simulations are presented of the spatially varying radiation conditions inside double-ended gold Hohlraums and single-ended gold Hohlraums (\u27\u27 halfraums \u27\u27) used in inertial confinement fusion and high-energy density physics experiments [J. Lindl, Phys. Plasmas 11, 339 (2004); M. D. Rosen, Phys. Plasmas 3, 1803 (1996)]. It is shown that in many circumstances, the common assumption that the Hohlraum \u27\u27 drive \u27\u27 can be characterized by a single temperature is too simplistic. Specifically, the radiation conditions seen by an experimental package can differ significantly from the wall reemission measured through diagnostic holes or laser entrance holes (LEHs) by absolutely calibrated detectors. Furthermore, even in situations where the radiation temperature is roughly the same for diagnostics and experimental packages, or for packages at different locations, the spectral energy distributions can vary significantly, due to the differing fractions of reemitting wall, laser hot spots, and LEHs seen from different locations. We find that the spatial variation of temperature and especially the differences between what diagnostics looking in the LEH measure versus the radiation temperature on wall-mounted experimental packages are generally greater for double-ended Hohlraums than for halfraums. View-factor simulations can also be used to explore experimental variables (halfraum length and geometry, sample position, and beam pointing) that can be adjusted in order to, for example, maximize the radiation flux onto a sample, or other package. In this vein, simulations of Hohlraums and halfraums with LEH shields are also presented. (c) 2005 American Institute of Physics

    New Challenges For Wind Shock Models: The Chandra Spectrum Of The Hot Star Delta Orionis

    Get PDF
    The Chandra spectrum of delta Ori A shows emission lines from hydrogen- and helium-like states of Si, Mg, Ne, and O, along with N VII Lyalpha and lines from ions in the range Fe XVII-Fe XXI In contrast to the broad lines seen in zeta Pup and zeta Ori (850 +/- 40 and 1000 +/- 240 km s(-1) half-width at half-maximum [HWHM], respectively), these lines are broadened to only 430 +/- 60 km s(-1) HWHM. This is much lower than the measured wind terminal velocity of 2000 km s(-1). The forbidden, intercombination, and resonance (fir) lines from He-like ions indicate that the majority of the X-ray line emission does not originate at the base of the wind, in agreement with the standard wind shock models for these objects. However, in that model the X-ray emission is distributed throughout an expanding, X-ray-absorbing wind, and it is therefore surprising that the emission lines appear relatively narrow, unshifted, and symmetric. We compare the observed line profiles to recent detailed models for X-ray line pro le generation in hot stars, but none of them offers a fully satisfactory explanation for the observed line profiles

    High-Resolution Chandra Spectroscopy Of Tau Scorpii: A Narrow-Line X-Ray Spectrum From A Hot Star

    Get PDF
    Long known to be an unusual early-type star by virtue of its hard and strong X-ray emission, tau Scorpii poses a severe challenge to the standard picture of O-star wind-shock X-ray emission. The Chandra HETGS spectrum now provides significant direct evidence that this B0.2 star does not fit this standard wind-shock framework. The many emission lines detected with the Chandra gratings are significantly narrower than what would be expected from a star with the known wind properties of tau Sco, although they are broader than the corresponding lines seen in late-type coronal sources. While line ratios are consistent with the hot plasma on this star being within a few stellar radii of the photosphere, from at least one He-like complex there is evidence that the X-ray emitting plasma is located more than a stellar radius above the photosphere. The Chandra spectrum of Sco is harder and more variable than those of other hot stars, with the exception of the young magnetized O star theta(1) Ori C. We discuss these new results in the context of wind, coronal, and hybrid wind-magnetic models of hot-star X-ray emission

    X-Ray Spectral Diagnostics Of Neon Photoionization Experiments On The Z-Machine

    Get PDF
    We report on an initial spectroscopic study of low-density, x-ray photoionized neon with x-ray spectroscopy. These experiments, carried out on the Z-machine at Sandia, are optimized to produce a gradient-free, collisionless plasma, and to explore issues related to the rapid x-ray photoionization of relatively cold, low-density plasmas. The initial experiments used time-integrated absorption spectroscopy, backlit by the pinch radiation, to determine the ionization balance in the gas cell. Future experiments will use time-resolved spectroscopy in both absorption and emission. The emission spectra are expected to be similar to those seen from photoionized astrophysical sources, such as x-ray binaries. Indeed, in addition to addressing basic plasma and atomic physics issues, these experiments are designed to help the astrophysical community better understand the new, high-resolution spectra being produced by the Chandra and XMM-Newton telescopes, and to benchmark spectral synthesis codes

    Chandra HETGS Multiphase Spectroscopy Of The Young Magnetic O Star Theta(1) Orionis C

    Get PDF
    We report on four Chandra grating observations of the oblique magnetic rotator theta(1) Ori C (O5.5 V), covering a wide range of viewing angles with respect to the star\u27s 1060 G dipole magnetic field. We employ line-width and centroid analyses to study the dynamics of the X-ray - emitting plasma in the circumstellar environment, as well as line-ratio diagnostics to constrain the spatial location, and global spectral modeling to constrain the temperature distribution and abundances of the very hot plasma. We investigate these diagnostics as a function of viewing angle and analyze them in conjunction with new MHD simulations of the magnetically channeled wind shock mechanism on theta(1) Ori C. This model fits all the data surprisingly well, predicting the temperature, luminosity, and occultation of the X-ray - emitting plasma with rotation phase

    Spontaneous very preterm birth in relation to social class, and smoking : a temporal-spatial analysis of routinely collected data in Aberdeen, Scotland (1985–2010)

    Get PDF
    Authors thanks goes to the Data Management Team, University of Aberdeen for extracting the data. Many thanks to Charles Opondo for his comments on the manuscript.Peer reviewedPostprin

    An X-Ray Analysis Database of Photoionization Cross Sections Including Variable Ionization

    Get PDF
    Results of research efforts in the following areas are discussed: review of the major theoretical and experimental data of subshell photoionization cross sections and ionization edges of atomic ions to assess the accuracy of the data, and to compile the most reliable of these data in our own database; detailed atomic physics calculations to complement the database for all ions of 17 cosmically abundant elements; reconciling the data from various sources and our own calculations; and fitting cross sections with functional approximations and incorporating these functions into a compact computer code.Also, efforts included adapting an ionization equilibrium code, tabulating results, and incorporating them into the overall program and testing the code (both ionization equilibrium and opacity codes) with existing observational data. The background and scientific applications of this work are discussed. Atomic physics cross section models and calculations are described. Calculation results are compared with available experimental data and other theoretical data. The functional approximations used for fitting cross sections are outlined and applications of the database are discussed

    Scotland Registry for Ankylosing Spondylitis (SIRAS) – Protocol

    Get PDF
    Funding SIRAS was funded by unrestricted grants from Pfizer and AbbVie. The project was reviewed by both companies, during the award process, for Scientific merit, to ensure that the design did not compromise patient safety, and to assess the global regulatory implications and any impact on regulatory strategy.Publisher PD
    corecore