287 research outputs found

    Incorporating the Aortic Valve into Computational Fluid Dynamics Models using Phase-Contrast MRI and Valve Tracking

    Get PDF
    The American Heart Association states about 2% of the general population have a bicuspid aortic valve (BAV). BAVs exist in 80% of patients with aortic coarctation (CoA) and likely influences flow patterns that contribute to long-term morbidity post-surgically. BAV patients tend to have larger ascending aortic diameters, increased risk of aneurysm formation, and require surgical intervention earlier than patients with a normal aortic valve. Magnetic resonance imaging (MRI) has been used clinically to assess aortic arch morphology and blood flow in these patients. These MRI data have been used in computational fluid dynamics (CFD) studies to investigate potential adverse hemodynamics in these patients, yet few studies have attempted to characterize the impact of the aortic valve on ascending aortic hemodynamics. To address this issue, this research sought to identify the impact of aortic valve morphology on hemodynamics in the ascending aorta and determine the location where the influence is negligible. Novel tools were developed to implement aortic valve morphology into CFD models and compensate for heart motion in MRI flow measurements acquired through the aortic valve. Hemodynamic metrics such as blood flow velocity, time-averaged wall shear stress (TAWSS), and turbulent kinetic energy (TKE) induced by the valve were compared to values obtained using the current plug inflow approach. The influence of heart motion on these metrics was also investigated, resulting in the underestimation of TAWSS and TKE when heart motion was neglected. CFD simulations of CoA patients exhibiting bicuspid and tricuspid aortic valves were performed in models including the aortic sinuses and patient-specific valves. Results indicated the aortic valve impacted hemodynamics primarily in the ascending aorta, with the BAV having the greatest influence along the outer right wall of the vessel. A marked increase in TKE is present in aortic valve simulations, particularly in BAV patients. These findings suggest that future CFD studies investigating altered hemodynamics in the ascending aorta should accurately replicate aortic valve morphology. Further, aortic valve disease impacts hemodynamics in the ascending aorta that may be a predictor of the development or progression of ascending aortic dilation and possible aneurysm formation in this region

    Treating a 20 mm Hg Gradient Alleviates Myocardial Hypertrophy in Experimental Aortic Coarctation

    Get PDF
    Background Children with coarctation of the aorta (CoA) can have a hyperdynamic and remodeled left ventricle (LV) from increased afterload. Literature from an experimental model suggests the putative 20 mm Hg blood pressure gradient (BPG) treatment guideline frequently implemented in CoA studies may permit irreversible vascular changes. LV remodeling from pressure overload has been studied, but data are limited following correction and using a clinically representative BPG. Materials and methods Rabbits underwent CoA at 10 weeks to induce a 20 mm Hg BPG using permanent or dissolvable suture thereby replicating untreated and corrected CoA, respectively. Cardiac function was evaluated at 32 weeks by magnetic resonance imaging using a spoiled cine GRE sequence (TR/TE/FA 8/2.9/20), 14 × 14-cm FOV, and 3-mm slice thickness. Images (20 frames/cycle) were acquired in 6-8 short axis views from the apex to the mitral valve annulus. LV volume, ejection fraction (EF), and mass were quantified. Results LV mass was elevated for CoA (5.2 ± 0.55 g) versus control (3.6 ± 0.16 g) and corrected (4.0 ± 0.44 g) rabbits, resulting in increased LV mass/volume ratio for CoA rabbits. A trend toward increased EF and stroke volume was observed but did not reach significance. Elevated EF by volumetric analysis in CoA rabbits was supported by concomitant increases in total aortic flow by phase-contrast magnetic resonance imaging. Conclusions The indices quantified trended toward a persistent hyperdynamic LV despite correction, but differences were not statistically significant versus control rabbits. These findings suggest the current putative 20 mm Hg BPG for treatment may be reasonable from the LV\u27s perspective

    Including Aortic Valve Morphology in Computational Fluid Dynamics Simulations: Initial Findings and Application to Aortic Coarctation

    Get PDF
    Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to develop a method to account for the AoV in CFD simulations, and quantify its impact on local hemodynamics. The method developed facilitates segmentation of the AoV, spatiotemporal interpolation of segments, and anatomic positioning of segments at the CFD model inlet. The AoV was included in CFD model examples of a normal (tricuspid AoV) and a post-surgical CoA patient (BAV). Velocity, turbulent kinetic energy (TKE), time-averaged wall shear stress (TAWSS), and oscillatory shear index (OSI) results were compared to equivalent simulations using a plug inlet profile. The plug inlet greatly underestimated TKE for both examples. TAWSS differences extended throughout the thoracic aorta for the CoA BAV, but were limited to the arch for the normal example. OSI differences existed mainly in the ascending aorta for both cases. The impact of AoV can now be included with CFD simulations to identify regions of deleterious hemodynamics thereby advancing simulations of the thoracic aorta one step closer to reality

    A Coupled Experimental and Computational Approach to Quantify Deleterious Hemodynamics, Vascular Alterations, and Mechanisms of Long-Term Morbidity in Response to Aortic Coarctati

    Get PDF
    Introduction Coarctation of the aorta (CoA) is associated with morbidity despite treatment. Although mechanisms remain elusive, abnormal hemodynamics and vascular biomechanics are implicated. We present a novel approach that facilitates quantification of coarctation-induced mechanical alterations and their impact on vascular structure and function, without genetic or confounding factors. Methods Rabbits underwent thoracic CoA at 10 weeks of age (~ 9 human years) to induce a 20 mm Hg blood pressure (BP) gradient using permanent or dissolvable suture thereby replicating untreated and corrected CoA. Computational fluid dynamics (CFD) was performed using imaging and BP data at 32 weeks to quantify velocity, strain and wall shear stress (WSS) for comparison to vascular structure and function as revealed by histology and myograph results. Results Systolic and mean BP was elevated in CoA compared to corrected and control rabbits leading to vascular thickening, disorganization and endothelial dysfunction proximally and distally. Corrected rabbits had less severe medial thickening, endothelial dysfunction, and stiffening limited to the proximal region despite 12 weeks of normal BP (~ 4 human years) after the suture dissolved. WSS was elevated distally for CoA rabbits, but reduced for corrected rabbits. Discussion These findings are consistent with alterations in humans. We are now poised to investigate mechanical contributions to mechanisms of morbidity in CoA using these methods

    Where attention goes, energy flows : enhancing individual sustainability in software engineering

    Get PDF
    Software engineers are plagued by the same troubles as many others in highly skilled jobs and digitized environments: Ever-expanding to-do lists, time to market pressure from management, deadline- driven development, continuous interruption during working tasks, and the juggle of balancing that with other areas of life (physical, mental and emotional health, family, household, finance, friends, hobbies and community service). These demands of life in combina- tion with a seemingly ever-increasing pace wear or burn out many people in the long run. Specifically, as software engineers, this also leads to decreased creativity and less efficiency in problem-solving. Generally offered solutions are reducing screen time and spending more time outdoors, both of which are hard to do within the work of a software engineer. On a meta level, if the developers of the systems that run most of our world do not develop individual sus- tainability with a balanced pace of life, that imbalance propagates into the systems we develop (similar to Conway’s Law). We argue that mindfulness practices like yoga poses (asanas), breathing prac- tices, and meditation exercises can help individually, and even more effectively in combination. In this exploratory paper, we discuss related work that explores the application of these mitigations in other application domains and propose a research agenda to explore their use within software engineering education and practice.Engaging with mindfulness practices in the context of software engineering promises to enhance creativity and cognitive problem- solving skills, leading to more efficiency and effectiveness during software development and increased individual sustainability. This, in turn, leads to better team spirit as well as increased economic profit, both in terms of maintaining human capital and customer contract deliverables

    Impact of Booster Breaks and Computer Prompts on Physical Activity and Sedentary Behavior Among Desk-Based Workers: A Cluster-Randomized Controlled Trial

    Get PDF
    Introduction The 15-minute work break provides an opportunity to promote health, yet few studies have examined this part of the workday. We studied physical activity and sedentary behavior among office workers and compared the results of the Booster Break program with those of a second intervention and a control group to determine whether the Booster Break program improved physical and behavioral health outcomes. Methods We conducted a 3-arm, cluster-randomized controlled trial at 4 worksites in Texas from 2010 through 2013 to compare a group-based, structured Booster Break program to an individual-based computer-prompt intervention and a usual-break control group; we analyzed physiologic, behavioral, and employee measures such as work social support, quality of life, and perceived stress. We also identified consistent and inconsistent attendees of the Booster Break sessions. Results We obtained data from 175 participants (mean age, 43 y; 67% racial/ethnic minority). Compared with the other groups, the consistent Booster Break attendees had greater weekly pedometer counts (P \u3c .001), significant decreases in sedentary behavior and self-reported leisure-time physical activity (P \u3c .001), and a significant increase in triglyceride concentrations (P = .02) (levels remained within the normal range). Usual-break participants significantly increased their body mass index, whereas Booster Break participants maintained body mass index status during the 6 months. Overall, Booster Break participants were 6.8 and 4.3 times more likely to have decreases in BMI and weekend sedentary time, respectively, than usual-break participants. Conclusion Findings varied among the 3 study groups; however, results indicate the potential for consistent attendees of the Booster Break intervention to achieve significant, positive changes related to physical activity, sedentary behavior, and body mass index

    ‘Super disabilities’ vs ‘Disabilities’?:Theorizing the role of ableism in (mis)representational mythology of disability in the marketplace

    Get PDF
    People with disabilities (PWD) constitute one of the largest minority groups with one in five people worldwide having a disability. While recognition and inclusion of this group in the marketplace has seen improvement, the effects of (mis)representation of PWD in shaping the discourse on fostering marketplace inclusion of socially marginalized consumers remain little understood. Although effects of misrepresentation (e.g., idealized, exoticized or selective representation) on inclusion/exclusion perceptions and cognitions has received attention in the context of ethnic/racial groups, the world of disability has been largely neglected. By extending the theory of ableism into the context of PWD representation and applying it to the analysis of the We’re the Superhumans advertisement developed for the Rio 2016 Paralympic Games, this paper examines the relationship between the (mis)representation and the inclusion/exclusion discourse. By uncovering that PWD misrepresentations can partially mask and/or redress the root causes of exclusion experienced by PWD in their lived realities, it contributes to the research agenda on the transformative role of consumption cultures perpetuating harmful, exclusionary social perceptions of marginalized groups versus contributing to advancement of their inclusion
    • …
    corecore