129 research outputs found
Multiabsorber Transition-Edge Sensors for X-Ray Astronomy
We are developing arrays of position-sensitive microcalorimeters for future x-ray astronomy applications. These position-sensitive devices commonly referred to as hydras consist of multiple x-ray absorbers, each with a different thermal coupling to a single-transition-edge sensor microcalorimeter. Their development is motivated by a desire to achieve very large pixel arrays with some modest compromise in performance. We report on the design, optimization, and first results from devices with small pitch pixels (<75 m) being developed for a high-angular and energy resolution imaging spectrometer for Lynx. The Lynx x-ray space telescope is a flagship mission concept under study for the National Academy of Science 2020 decadal survey. Broadband full-width-half-maximum (FWHM) resolution measurements on a 9-pixel hydra have demonstrated E(FWHM) = 2.23 0.14 eV at Al-K, E(FWHM) = 2.44 0.29 eV at Mn-K, and E(FWHM) = 3.39 0.23 eV at Cu-K. Position discrimination is demonstrated to energies below <1 keV and the device performance is well-described by a finite-element model. Results from a prototype 20-pixel hydra with absorbers on a 50-m pitch have shown E(FWHM) = 3.38 0.20 eV at Cr-K1. We are now optimizing designs specifically for Lynx and extending the number of absorbers up to 25/hydra. Numerical simulation suggests optimized designs could achieve 3 eV while being compatible with the bandwidth requirements of the state-of-the art multiplexed readout schemes, thus making a 100,000 pixel microcalorimeter instrument a realistic goal
Sociological and Human Developmental Explanations of Crime: Conflict or Consensus
This paper examines multidisciplinary correlates of delinquency in an attempt to integrate sociological and environmental theories of crime with human developmental and biological explanations of crime. Structural equation models are applied to assess links among biological, psychological, and environmental variables collected prospectively from birth through age 17 on a sample of 800 black children at high risk for learning and behavioral disorders. Results show that for both males and females, aggression and disciplinary problems in school during adolescence are the strongest predictors of repeat offense behavior. Whereas school achievement and family income and stability are also significant predictors of delinquency for males, early physical development is the next strongest predictor for females. Results indicate that some effects on delinquency also vary during different ages. It is suggested that behavioral and learning disorders have both sociological and developmental correlates and that adequate educational resources are necessary to ensure channels of legitimate opportunities for high-risk youths
Performance and on-sky optical characterization of the SPTpol instrument
In January 2012, the 10m South Pole Telescope (SPT) was equipped with a
polarization-sensitive camera, SPTpol, in order to measure the polarization
anisotropy of the cosmic microwave background (CMB). Measurements of the
polarization of the CMB at small angular scales (~several arcminutes) can
detect the gravitational lensing of the CMB by large scale structure and
constrain the sum of the neutrino masses. At large angular scales (~few
degrees) CMB measurements can constrain the energy scale of Inflation. SPTpol
is a two-color mm-wave camera that consists of 180 polarimeters at 90 GHz and
588 polarimeters at 150 GHz, with each polarimeter consisting of a dual
transition edge sensor (TES) bolometers. The full complement of 150 GHz
detectors consists of 7 arrays of 84 ortho-mode transducers (OMTs) that are
stripline coupled to two TES detectors per OMT, developed by the TRUCE
collaboration and fabricated at NIST. Each 90 GHz pixel consists of two
antenna-coupled absorbers coupled to two TES detectors, developed with Argonne
National Labs. The 1536 total detectors are read out with digital
frequency-domain multiplexing (DfMUX). The SPTpol deployment represents the
first on-sky tests of both of these detector technologies, and is one of the
first deployed instruments using DfMUX readout technology. We present the
details of the design, commissioning, deployment, on-sky optical
characterization and detector performance of the complete SPTpol focal plane.Comment: 15 pages, 6 figures. Conference: SPIE Astronomical Telescopes and
Instrumentation 201
Feedhorn-coupled TES polarimeter camera modules at 150 GHz for CMB polarization measurements with SPTpol
The SPTpol camera is a dichroic polarimetric receiver at 90 and 150 GHz.
Deployed in January 2012 on the South Pole Telescope (SPT), SPTpol is looking
for faint polarization signals in the Cosmic Microwave Background (CMB). The
camera consists of 180 individual Transition Edge Sensor (TES) polarimeters at
90 GHz and seven 84-polarimeter camera modules (a total of 588 polarimeters) at
150 GHz. We present the design, dark characterization, and in-lab optical
properties of the 150 GHz camera modules. The modules consist of
photolithographed arrays of TES polarimeters coupled to silicon platelet arrays
of corrugated feedhorns, both of which are fabricated at NIST-Boulder. In
addition to mounting hardware and RF shielding, each module also contains a set
of passive readout electronics for digital frequency-domain multiplexing. A
single module, therefore, is fully functional as a miniature focal plane and
can be tested independently. Across the modules tested before deployment, the
detectors average a critical temperature of 478 mK, normal resistance R_N of
1.2 Ohm, unloaded saturation power of 22.5 pW, (detector-only) optical
efficiency of ~ 90%, and have electrothermal time constants < 1 ms in
transition.Comment: 15 pages, 11 figure
- …