16 research outputs found

    High-angular and high-contrast VLTI observations from Y to M band with the Asgard instrumental suite

    Get PDF
    This is the final version. Available from SPIE via the DOI in this recordSPIE Astronomical Telescopes + Instrumentation 2022, 17 - 22 July 2022, Montreal, CanadaThe Very Large Telescope Interferometer is one of the most proficient observatories in the world for high angular resolution. Since its first observations, it has hosted several interferometric instruments operating in various bandwidths in the infrared. As a result, the VLTI yields countless discoveries and technological breakthroughs. We introduce to the VLTI the new concept of Asgard: an instrumental suite including four natively collaborating instruments: BIFROST, a stellar interferometer dedicated to the study of the formation of multiple systems; Hi- 5, a nulling interferometer dedicated to imaging young nearby planetary systems in the M band; HEIMDALLR, an all-in-one instrument performing both fringe tracking and stellar interferometry with the same optics; Baldr, a fibre-injection optimiser. These instruments share common goals and technologies. Thus, the idea of this suite is to make the instruments interoperable and complementary to deliver unprecedented sensitivity and accuracy from J to M bands. The interoperability of the Asgard instruments and their integration in the VLTI are the main challenges of this project. In this paper, we introduce the overall optical design of the Asgard suite, the different modules, and the main challenges ahead.European Union Horizon 2020Science and Technology Facilities Council (STFC)European Research Council (ERC

    Review and scientific prospects of high-contrast optical stellar interferometry

    Get PDF
    This is the final version. Available from SPIE via the DOI in this recordSPIE Astronomical Telescopes + Instrumentation conference, 14 - 18 December 2020, Online OnlyHigh-contrast optical stellar interferometry generally refers to instruments able to detect circumstellar emission at least a few hundred times fainter than the host star at high-angular resolution (typically within a few λ/D). While such contrast levels have been enabled by classical modal-filtered interferometric instruments such as VLTI/PIONIER, CHARA/FLUOR, and CHARA/MIRC the development of instruments able to filter out the stellar light has significantly pushed this limit, either by nulling interferometry for on-axis observations (e.g., PFN, LBTI, GLINT) or by off-axis classical interferometry with VLTI/GRAVITY. Achieving such high contrast levels at small angular separation was made possible thanks to significant developments in technology (e.g., adaptive optics, integrated optics), data acquisition (e.g., fringe tracking, phase chopping), and data reduction techniques (e.g., nulling self-calibration). In this paper, we review the current status of high-contrast optical stellar interferometry and present its key scientific results. We then present ongoing activities to improve current ground-based interferometric facilities for high-contrast imaging (e.g., Hi-5/VIKING/BIFROST of the ASGARD instrument suite, GRAVITY+) and the scientific milestones that they would be able to achieve. Finally, we discuss the long-term future of high-contrast stellar interferometry and, in particular, ambitious science cases that would be enabled by space interferometry (e.g., LIFE, space-PFI) and large-scale ground-based projects (PFI).European Research Council (ERC

    Technical requirements and optical design of the Hi-5 spectrometer

    No full text
    Hi-5 is a proposed L' band high-contrast nulling interferometric instrument for the visitor focus of the Very Large Telescope Interferometer (VLTI). As a part of the ERC consolidator project called SCIFY (Self-Calibrated Interferometry For exoplanet spectroscopY), the instrument aims to achieve sufficient dynamic range and angular resolution to directly image and characterize the snow line of young extra-solar planetary systems. The spectrometer is based on a dispersive grism and is located downstream of an integrated optics beam-combiner. To reach the contrast and sensitivity specifications, the outputs of the I/O chip must be sufficiently separated and properly sampled on the Hawaii-2RG detector. This has many implications for the photonic chip and spectrometer design. We present these technical requirements, trade-off studies, and phase-A of the optical design of the Hi-5 spectrometer in this paper. For both science and contract-driven reasons, the instrument design currently features three different spectroscopic modes (R=20, 400, and 2000). Designs and efficiency estimates for the grisms are also presented as well as the strategy to separate the two polarization states

    VLTI/Hi-5: detection yield predictions for young giant exoplanets

    No full text
    The Hi-5 instrument, a proposed high-contrast L' band (3.5-4.0 μm) nulling interferometer for the visitor focus of the Very Large Telescope Interferometer (VLTI), will characterize young extra-solar planetary systems and exozodiacal dust around nearby main-sequence stars. Thanks to VLTI's angular resolution (λ=B = 5 mas for the longest UT baseline), it will fill the gap between young giant exoplanets discovered by ongoing single-aperture direct imaging surveys and exoplanet populations discovered by radial velocity surveys. In this paper, we investigate the exoplanet detection yield of Hi-5. First, we present the latest catalog of stars identified as members of young stellar associations within 150 pc of the Sun thanks to the BANYAN algorithm and other searches for young moving group members. Realistic exoplanet populations are then generated around these stars and processed with the SCIFYsim tool, the end-to-end simulator for the Hi-5 instrument. Then, two formation models are used to estimate the giant planet's luminosity. The first is the New Generation Planetary Population Synthesis (NGPPS), also known as the Bern model, and the second is a statistical model based on gravitational instability (hot-start model - AMES-Dusty model). We show that Hi-5 is insensitive to cold-start planets but can detect giant hot-start planets. With ATs, more than 40 planets could be detected assuming 20 nights of observations. With its unique capabilities, Hi-5 is also able to constrain in mass the observed systems. Hi-5 is sensitive to planets with a mass > 2 Mjup around the snow line

    L-band nulling interferometry at the VLTI with Asgard/Hi-5: status and plans

    No full text
    Hi-5 is the L’-band (3.5-4.0 μm) high-contrast imager of Asgard, an instrument suite in preparation for the visitor focus of the VLTI. The system is optimized for high-contrast and high-sensitivity imaging within the diffraction limit of a single UT/AT telescope. It is designed as a double-Bracewell nulling instrument producing spectrally-dispersed (R=20, 400, or 2000) complementary nulling outputs and simultaneous photometric outputs for self-calibration purposes. In this paper, we present an update of the project with a particular focus on the overall architecture, opto-mechanical design of the warm and cold optics, injection system, and development of the photonic beam combiner. The key science projects are to survey (i) nearby young planetary systems near the snow line, where most giant planets are expected to be formed, and (2) nearby main sequence stars near the habitable zone where exozodiacal dust that may hinder the detection of Earth-like planets. We present an update of the expected instrumental performance based on full end-to-end simulations using the new GRAVITY+ specifications of the VLTI and the latest planet formation models

    VLTI/Hi-5: detection yield predictions for young giant exoplanets

    No full text
    The Hi-5 instrument, a proposed high-contrast L' band (3.5-4.0 μm) nulling interferometer for the visitor focus of the Very Large Telescope Interferometer (VLTI), will characterize young extra-solar planetary systems and exozodiacal dust around nearby main-sequence stars. Thanks to VLTI's angular resolution (λ=B = 5 mas for the longest UT baseline), it will fill the gap between young giant exoplanets discovered by ongoing single-aperture direct imaging surveys and exoplanet populations discovered by radial velocity surveys. In this paper, we investigate the exoplanet detection yield of Hi-5. First, we present the latest catalog of stars identified as members of young stellar associations within 150 pc of the Sun thanks to the BANYAN algorithm and other searches for young moving group members. Realistic exoplanet populations are then generated around these stars and processed with the SCIFYsim tool, the end-to-end simulator for the Hi-5 instrument. Then, two formation models are used to estimate the giant planet's luminosity. The first is the New Generation Planetary Population Synthesis (NGPPS), also known as the Bern model, and the second is a statistical model based on gravitational instability (hot-start model - AMES-Dusty model). We show that Hi-5 is insensitive to cold-start planets but can detect giant hot-start planets. With ATs, more than 40 planets could be detected assuming 20 nights of observations. With its unique capabilities, Hi-5 is also able to constrain in mass the observed systems. Hi-5 is sensitive to planets with a mass > 2 Mjup around the snow line.Spaceborne Instrumentatio

    Technical requirements and optical design of the Hi-5 spectrometer

    No full text
    Hi-5 is a proposed L' band high-contrast nulling interferometric instrument for the visitor focus of the Very Large Telescope Interferometer (VLTI). As a part of the ERC consolidator project called SCIFY (Self-Calibrated Interferometry For exoplanet spectroscopY), the instrument aims to achieve sufficient dynamic range and angular resolution to directly image and characterize the snow line of young extra-solar planetary systems. The spectrometer is based on a dispersive grism and is located downstream of an integrated optics beam-combiner. To reach the contrast and sensitivity specifications, the outputs of the I/O chip must be sufficiently separated and properly sampled on the Hawaii-2RG detector. This has many implications for the photonic chip and spectrometer design. We present these technical requirements, trade-off studies, and phase-A of the optical design of the Hi-5 spectrometer in this paper. For both science and contract-driven reasons, the instrument design currently features three different spectroscopic modes (R=20, 400, and 2000). Designs and efficiency estimates for the grisms are also presented as well as the strategy to separate the two polarization states.Spaceborne Instrumentatio

    L-band nulling interferometry at the VLTI with Asgard/Hi-5: status and plans

    No full text
    Hi-5 is the L’-band (3.5-4.0 μm) high-contrast imager of Asgard, an instrument suite in preparation for the visitor focus of the VLTI. The system is optimized for high-contrast and high-sensitivity imaging within the diffraction limit of a single UT/AT telescope. It is designed as a double-Bracewell nulling instrument producing spectrally-dispersed (R=20, 400, or 2000) complementary nulling outputs and simultaneous photometric outputs for self-calibration purposes. In this paper, we present an update of the project with a particular focus on the overall architecture, opto-mechanical design of the warm and cold optics, injection system, and development of the photonic beam combiner. The key science projects are to survey (i) nearby young planetary systems near the snow line, where most giant planets are expected to be formed, and (2) nearby main sequence stars near the habitable zone where exozodiacal dust that may hinder the detection of Earth-like planets. We present an update of the expected instrumental performance based on full end-to-end simulations using the new GRAVITY+ specifications of the VLTI and the latest planet formation models.Spaceborne Instrumentatio
    corecore