113 research outputs found

    A cusp catastrophe model of mid–long-term landslide evolution over low latitude highlands of China

    Get PDF
    AbstractBased on a model describing a certain landslide case and catastrophe theory, we derived a cusp catastrophe model and corresponding inversion method to study mid–long-term landslide evolution. According to data of landslides, precipitation, and socioeconomic development from 1976 to 2008, the cusp catastrophe model describing this landslide evolution across a low-latitude highland area in China is obtained with the least squares method. Results of the model indicate that human activity determines landslide intensity. Local precipitation also impacts yearly landslide intensity to some extent, and controls the time when a strong and abrupt change in landslides occurs. During the period 1976–2008, there was an abrupt decrease of landslide intensity during 1994–1995, and an abrupt increase during 1995–1996. Since then, there have been frequent landslides in the low-latitude highland, with greater intensity. All these factors provide a scientific basis for formulating a contingency plan regarding landslide disasters

    Effectiveness and safety of transcatheter aortic valve replacement in elderly people with severe aortic stenosis with different types of heart failure.

    Get PDF
    Impaired left ventricular function is an independent predictor of adverse clinical outcomes in patients with aortic stenosis. The aim of this study is to evaluate the short-term changes of echocardiographic parameters, New York Heart Association (NYHA) class and B-type natriuretic peptide (BNP) level and adverse events amongst patients with heart failure (HF) after transcatheter aortic valve replacement (TAVR) procedure. This was a retrospective cohort study conducted at affiliated Yantai Yuhuangding Hospital of Qingdao University between September 2017 and September 2022. TAVR cases were stratified into three groups [heart failure with reduced ejection fraction (HFrEF), heart failure with mildly reduced ejection fraction (HFmrEF), heart failure with preserved ejection fraction (HFpEF)] by left ventricular ejection fraction (LVEF). Baseline characteristics, changes in echocardiographic parameters (1 week and 1 month), BNP (1 month), and NYHA class (6 months) post-TAVR were compared across the three groups. Meanwhile, we observed the adverse events of the patients after TAVR. A total of 96 patients were included, of whom 15 (15.6%) had HFrEF, 15 (15.6%) had HFmrEF, and 66 (68.8%) had HFpEF. Compared to the HFpEF subgroup, patients in the HFrEF subgroup were younger (p < 0.05), and with a higher BNP (p < 0.05). The left ventricular end-diastolic dimension (LVEDD) in HFrEF group decreased significantly after TAVR. HFmrEF and HFrEF patients showed significant improvements in LVEF after TAVR. The pulmonary artery systolic pressure (PASP), aortic valve peak gradient (AVPG) and aortic valve peak gradient (V ) decreased significantly 1 month after TAVR in all three groups compared to the baseline (all p < 0.05). BNP significantly reduced in HFrEF group compared to HFpEF patients after TAVR (p < 0.05). The majority of patients experienced an improvement at least one NYHA class in all three groups 6 months post-TAVR. There is no significant increase in the risk of adverse events in the HFrEF group. Patients who underwent TAVR achieved significant improvements in BNP, NYHA class, LVEDD, LVEF, and PASP across the three HF classes, with a more rapid and pronounced improvement in the HFrEF and HFmrEF groups. Complication rates were low in the different HF groups. There is no significant increase in the risk of periprocedural complications in the HFrEF and HFmrEF groups. [Abstract copyright: © 2023. The Author(s).

    A Hybrid Deep Feature-Based Deformable Image Registration Method for Pathology Images

    Full text link
    Pathologists need to combine information from differently stained pathology slices for accurate diagnosis. Deformable image registration is a necessary technique for fusing multi-modal pathology slices. This paper proposes a hybrid deep feature-based deformable image registration framework for stained pathology samples. We first extract dense feature points via the detector-based and detector-free deep learning feature networks and perform points matching. Then, to further reduce false matches, an outlier detection method combining the isolation forest statistical model and the local affine correction model is proposed. Finally, the interpolation method generates the deformable vector field for pathology image registration based on the above matching points. We evaluate our method on the dataset of the Non-rigid Histology Image Registration (ANHIR) challenge, which is co-organized with the IEEE ISBI 2019 conference. Our technique outperforms the traditional approaches by 17% with the Average-Average registration target error (rTRE) reaching 0.0034. The proposed method achieved state-of-the-art performance and ranked 1st in evaluating the test dataset. The proposed hybrid deep feature-based registration method can potentially become a reliable method for pathology image registration.Comment: 22 pages, 12 figures. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessibl

    Effectiveness and safety of transcatheter aortic valve replacement in elderly people with severe aortic stenosis with different types of heart failure

    Get PDF
    Background: Impaired left ventricular function is an independent predictor of adverse clinical outcomes in patients with aortic stenosis. The aim of this study is to evaluate the short-term changes of echocardiographic parameters, New York Heart Association (NYHA) class and B-type natriuretic peptide (BNP) level and adverse events amongst patients with heart failure (HF) after transcatheter aortic valve replacement (TAVR) procedure. Methods: This was a retrospective cohort study conducted at affiliated Yantai Yuhuangding Hospital of Qingdao University between September 2017 and September 2022. TAVR cases were stratified into three groups [heart failure with reduced ejection fraction (HFrEF), heart failure with mildly reduced ejection fraction (HFmrEF), heart failure with preserved ejection fraction (HFpEF)] by left ventricular ejection fraction (LVEF). Baseline characteristics, changes in echocardiographic parameters (1 week and 1 month), BNP (1 month), and NYHA class (6 months) post-TAVR were compared across the three groups. Meanwhile, we observed the adverse events of the patients after TAVR. Results: A total of 96 patients were included, of whom 15 (15.6%) had HFrEF, 15 (15.6%) had HFmrEF, and 66 (68.8%) had HFpEF. Compared to the HFpEF subgroup, patients in the HFrEF subgroup were younger (p < 0.05), and with a higher BNP (p < 0.05). The left ventricular end-diastolic dimension (LVEDD) in HFrEF group decreased significantly after TAVR. HFmrEF and HFrEF patients showed significant improvements in LVEF after TAVR. The pulmonary artery systolic pressure (PASP), aortic valve peak gradient (AVPG) and aortic valve peak gradient (Vmax) decreased significantly 1 month after TAVR in all three groups compared to the baseline (all p < 0.05). BNP significantly reduced in HFrEF group compared to HFpEF patients after TAVR (p < 0.05). The majority of patients experienced an improvement at least one NYHA class in all three groups 6 months post-TAVR. There is no significant increase in the risk of adverse events in the HFrEF group. Conclusions: Patients who underwent TAVR achieved significant improvements in BNP, NYHA class, LVEDD, LVEF, and PASP across the three HF classes, with a more rapid and pronounced improvement in the HFrEF and HFmrEF groups. Complication rates were low in the different HF groups. There is no significant increase in the risk of periprocedural complications in the HFrEF and HFmrEF groups

    LDL-C: An important independent risk factor for new-onset heart block in patients with severe aortic stenosis and heart failure after TAVR

    Get PDF
    Transcatheter aortic valve replacement (TAVR) is an effective alternative treatment for patients with aortic stenosis (AS) who have intermediate to high surgical risk or who are inoperable. However, the incidence of conduction abnormalities is high after TAVR, which can reduce the effectiveness of the surgery. Our research objective is to explore the risk factors of new-onset conduction abnormalities after TAVR, providing reference value for clinical doctors to better prevent and treat conduction abnormalities. Patients who underwent TAVR were divided into those who developed heart block and those who did not. Baseline clinical characteristics, cardiac structural parameters, procedural characteristics, electrocardiogram (ECG) changes before and after TAVR ( = postoperative minus preoperative), and surgical complications were compared. Logistic regression was applied to identify significant risk factors for new-onset heart block. We studied 93 patients, of whom 34.4% developed heart blocks. Univariate logistic regression showed that prior history of malignancy, atrial fibrillation, preoperative high-level total cholesterol and low-density lipoprotein cholesterol (LDL-C), HR, QRS interval, QT interval, and QTc interval were risk factors of new-onset heart block after TAVR. Multivariate analysis showed that preoperative high-level LDL-C and QRS interval remained significant independent risk factors after adjusting for potential confounds. Heart block is the most common complication of TAVR, and its significant independent risk factors include high-level LDL-C and QRS interval. [Abstract copyright: Copyright: © 2023 The Author(s). Published by IMR Press.

    Sulfonated Dopant-Free Hole-Transport Material Promotes Interfacial Charge Transfer Dynamics for Highly Stable Perovskite Solar Cells

    Get PDF
    The integration of a functional group into dopant-free hole-transport materials (HTMs) to modify the perovskite|HTM interface has become a promising strategy for high-performance and stable perovskite solar cells (PSCs). In this work, a sulfonated phenothiazine-based HTM is reported, namely TAS, which consists of a butterfly structure with a readily synthesized N,​N-​bis[4-​(methylthio)​phenyl]​aniline side functional group. The interaction between TAS and perovskite via Pb–S bond induces a dipole moment that deepens the valence band of perovskite and thereby leads to enhanced open-circuit voltage in corresponding n-i-p PSCs. More importantly, the functionalization of perovskite surface via Pb–S bond promotes the hole extraction reaction while suppressing the interfacial non-radiative recombination, contributing to a 20–50% performance improvement compared to less- (4-​(methylthio)​-​N-​[4-​(methylthio)​phenyl]​aniline, DAS) or non-interacting (N,N-bis(4-methoxyphenyl)aniline, TAO) counterparts. Consequently, TAS-based PSCs exhibit superior device stability with a high PCE retention (>90% of the initial value) after 125 days of storage in the air.acceptedVersionPeer reviewe

    Sciences for The 2.5-meter Wide Field Survey Telescope (WFST)

    Full text link
    The Wide Field Survey Telescope (WFST) is a dedicated photometric survey facility under construction jointly by the University of Science and Technology of China and Purple Mountain Observatory. It is equipped with a primary mirror of 2.5m in diameter, an active optical system, and a mosaic CCD camera of 0.73 Gpix on the main focus plane to achieve high-quality imaging over a field of view of 6.5 square degrees. The installation of WFST in the Lenghu observing site is planned to happen in the summer of 2023, and the operation is scheduled to commence within three months afterward. WFST will scan the northern sky in four optical bands (u, g, r, and i) at cadences from hourly/daily to semi-weekly in the deep high-cadence survey (DHS) and the wide field survey (WFS) programs, respectively. WFS reaches a depth of 22.27, 23.32, 22.84, and 22.31 in AB magnitudes in a nominal 30-second exposure in the four bands during a photometric night, respectively, enabling us to search tremendous amount of transients in the low-z universe and systematically investigate the variability of Galactic and extragalactic objects. Intranight 90s exposures as deep as 23 and 24 mag in u and g bands via DHS provide a unique opportunity to facilitate explorations of energetic transients in demand for high sensitivity, including the electromagnetic counterparts of gravitational-wave events detected by the second/third-generation GW detectors, supernovae within a few hours of their explosions, tidal disruption events and luminous fast optical transients even beyond a redshift of 1. Meanwhile, the final 6-year co-added images, anticipated to reach g about 25.5 mag in WFS or even deeper by 1.5 mag in DHS, will be of significant value to general Galactic and extragalactic sciences. The highly uniform legacy surveys of WFST will also serve as an indispensable complement to those of LSST which monitors the southern sky.Comment: 46 pages, submitted to SCMP
    • …
    corecore