2,292 research outputs found

    Multiplex serum biomarker assessments: technical and biostatistical issues.

    Get PDF
    Identification of predictive and prognostic biomarkers for patients with disease and undergoing different therapeutic options is a very active area of investigation. Many of these studies seek biomarkers among circulating proteins accessed in blood. Many levels of standardization in materials and procedures have been identified which can impact the resulting data. Here, we have observed unexpected variability in levels of commonly tested analytes in serum which were processed and stored under standardized conditions. We have identified apparent changes in cytokine, chemokine and growth factor levels detected by multiplex Luminex assay in melanoma patient and healthy donor serum samples, over storage time at -80°C. Controls included Luminex kit standards, multiplexed cytokine standards and WHO cytokine controls. Data were analyzed by Wilcoxon rank-sum testing and Spearman's test for correlations. The interpretation of these changes is confounded by lot-to-lot kit standard curve reagent changes made by a single manufacturer of Luminex kits. This study identifies previously unknown sources of variation in a commonly used biomarker assay, and suggests additional levels of controls needed for identification of true changes in circulating protein levels

    Autoantibodies against retinal proteins in paraneoplastic and autoimmune retinopathy

    Get PDF
    BACKGROUND: Autoimmune retinal degeneration may occur in patients who present with sudden or, less commonly, subacute loss of vision of retinal origin, associated with an abnormal ERG, through the action of autoantibodies against retinal proteins. Often the patients are initially diagnosed with or suspected of having a paraneoplastic retinopathy (PR), such as cancer-associated retinopathy (CAR). However, there is limited information on the occurrence, the specificity of autoantibodies in these patients, and their association with clinical symptoms. METHODS: Sera were obtained from 193 retinopathy patients who presented with clinical symptoms resembling PR or autoimmune retinopathy (AR), including sudden painless loss of vision, typically associated with visual field defects and photopsias, and abnormal rod and/or cone responses on the electroretinogram (ERG). Sera were tested for the presence of anti-retinal autoantibodies by Western blot analysis using proteins extracted from human retina and by immunohistochemistry. Autoantibody titers against recoverin and enolase were measured by ELISA. RESULTS: We identified a higher prevalence of anti-retinal autoantibodies in retinopathy patients. Ninety-one patients' sera (47.1%) showed autoantibodies of various specificities with a higher incidence of antibodies present in retinopathy patients diagnosed with cancer (33/52; 63.5%; p = 0.009) than in retinopathy patients without cancer (58/141; 41.1%). The average age of PR patients was 62.0 years, and that of AR patients was 55.9 years. Autoantibodies against recoverin (p23) were only present in the sera of PR patients, autoantibodies against unknown p35 were more common in patients with AR, while anti-enolase (anti-p46) autoantibodies were nearly equally distributed in the sera of patients with PR and those with AR. In the seropositive patients, the autoantibodies persisted over a long period of time – from months to years. A rebound in anti-recoverin autoantibody titer was found to be associated with exacerbations in visual symptoms but not in the recurrence of cancer. When compared to sera from healthy subjects, autoantibodies against retinal proteins from both groups of patients were cytotoxic to retinal cells, indicating their pathogenic potential. CONCLUSIONS: These studies showed that patients with sudden or subacute, unexplained loss of vision of retinal origin have anti-retinal antibodies in a broad range of specificity and indicate the need for autoantibody screening. Follow-up tests of antibody levels may be useful as a biomarker of disease activity associated with worsening of vision. Moreover, the heterogeneity in autoantibody specificity may explain the variation and complexity of clinical symptoms in retinopathy patients

    The reliability and validity of three non-radiological measures of thoracic kyphosis and their relations to the standing radiological Cobb angle

    Get PDF
    UnlabelledHyperkyphosis is implicated in a mounting list of negative outcomes, including higher mortality. Hyperkyphosis research is hindered due to difficulties inherent in its measurement. By showing that three clinical measures of kyphosis are suitable for use in large scale, longitudinal, hyperkyphosis studies, we will facilitate much needed research in this field.IntroductionThe objective of this study is to describe the reliability of three non-radiological kyphosis measures (Debrunner kyphosis angle, flexicurve kyphosis index, and flexicurve kyphosis angle) and their validity compared to the Cobb angle and to approximate a Cobb angle from non-radiological kyphosis measures.MethodsWe analyzed data from 113 participants aged ≥ 60 years with kyphosis angle ≥ 40°. Cobb angle was measured on a standing lateral thoracolumbar radiograph using bounds at T4 and T12. Non-radiological measures of kyphosis were made three times by a single rater and a 4th time by a blinded second rater.ResultsIntra- and inter-rater reliabilities for non-radiological assessments were high (intra-class correlations of 0.96 to 0.98) and did not differ from each other. Pearson correlations, estimating validity, ranged from 0.62 to 0.69 and did not differ. The Debrunner angle was close to the Cobb angle, with scaling factor of 1.067 and an offset of 5°. The Flexicurve kyphosis angle had to be scaled by 1.53 to obtain the equivalent Cobb angle. The scaling factor for the Flexicurve kyphosis index to Cobb angle was 315, with an offset of 5°. Compared to the measured Cobb angle, Cobb angles predicted using the non-radiological measures had similar magnitude errors (standard deviations of the differences ranging between 10.24 and 11.26).ConclusionsEach non-radiological measurement had similar reliability and validity. Low cost, ease of use, and robustness to variations in spine contour argue for the Flexicurve in longitudinal kyphosis assessments. The approximate conversion factors provided will permit translation of non-radiological measures to Cobb angles

    Nutrition, lifestyle and colorectal cancer incidence: a prospective investigation of 10 998 vegetarians and non-vegetarians in the United Kingdom

    Get PDF
    In a cohort of 10998 men and women, 95 incident cases of colorectal cancer were recorded after 17 years. Risk increased in association with smoking, alcohol, and white bread consumption, and decreased with frequent consumption of fruit. The relative risk in vegetarians compared with nonvegetarians was 0.85 (95% CI: 0.55-1.32)

    Observation of the Ωc0\Omega_{c}^{0} Charmed Baryon at CLEO

    Full text link
    The CLEO experiment at the CESR collider has used 13.7 fb1^{-1} of data to search for the production of the Ωc0\Omega_c^0 (css-ground state) in e+ee^{+}e^{-} collisions at s10.6\sqrt{s} \simeq 10.6 {\rm GeV}. The modes used to study the Ωc0\Omega_c^0 are Ωπ+\Omega^- \pi^+, Ωπ+π0\Omega^- \pi^+ \pi^0, ΞKpi+π+\Xi^- K^- pi^+ \pi^+, Ξ0Kpi+\Xi^0 K^- pi^+, and Ωπ+ππ+\Omega^- \pi^+ \pi^- \pi^+. We observe a signal of 40.4±\pm9.0(stat) events at a mass of 2694.6±\pm2.6(stat)±\pm1.9(syst) {\rm MeV/c2c^2}, for all modes combined.Comment: 10 pages postscript, also available through http://w4.lns.cornell.edu/public/CLN
    corecore