258 research outputs found

    In vitro evaluation of carrier based obturation technique: a CBCT study

    Get PDF
    AIM: The goal of the study was to compare the ability of two different carrier based obturation (CBO) techniques to reach working length and fill in three-dimensions root canal systems, by using CBCT. MATERIALS AND METHODS: Twenty-six extracted molars were scanned with CBCT and 40 curved canals were selected (between 30° and 90°) and divided in two similar groups (n=20). All canals were prepared up to size 25 taper .06 using nickel-titanium instrumentation. The canals in the Group SC were obturated using Soft-Core obturators (Kerr, Romulus, Mi, USA), while Group TH canals (n= 20) were obturated using Thermafil Endodontic Obturators (Tulsa Dental Products, Tulsa, OK, USA), strictly following manufacturers' instructions for use. The obturations were analyzed by means of CBCT to measure the distance from the apical limit of obturation to the apical foramen and the presence of voids inside root canals. RESULTS: There was no significant difference between the two groups in the mean distance of the apical extent of the obturation (t test, p>0.05). Overfilling occurred in only 3 cases (2 in Group TH and 1 in Group SC). The percentages of voids in both groups were very low with no significant difference (Z test, p>0.05). CONCLUSIONS: The two tested CBO techniques showed similar positive results in terms of performance, even if, after checking with verifiers, in most cases the size of the selected Soft-Core obturator was one size smaller than Thermafil

    Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR : results at 3-year

    Get PDF
    Background: The aim of the present study was to radiographically evaluate the vertical socket walls changes, and the peri-implant marginal bone remodelling, and clinicallly the soft tissues conditions around the non-submerged single implants placed into the inter radicular septum of mandibular molar sockets, associated with a collagen membrane, after 3 years of loading.Material and Methods: Thirty patients underwent to placement of a non-submerged implants with a laser-micro-textured collar into the inter radicular septum of mandibular molar fresh extraction sockets. A collagen membrane and the mucoperiosteal flap were adapted around the neck of the implants, leaving the laser-microtextured collar to heal in a transmucosal fashion. Results: At the end of the follow-up period, no statistical differences were found for each radiographic measure-ments used for the examination of extraction sockets vertical bone changes. Compared to implants placement, at the end of the 3-year follow-up, the vertical radiographic mesial and distal peri-implant marginal bone levels showed a statistically significant gain of 0.9 (SD 0.5), and 1.0 mm (SD 0.6), respectively (P=0.037).Conclusions: in mandibular fresh extraction sockets, the method of GBR around transmucosal implants with la-ser-microtextured surface placed into the interadicular septum may be used successfully to counteract the ridge remodelling

    Full arch fixed prostheses vs. full arch telescopic-retained retrievable prostheses both supported by implants and natural tooth abutments in periodontally treated patients : results at 15 years

    Get PDF
    The clinical outcome of full arch fixed prostheses vs. full arch telescopic-retained retrievable prostheses supported by implants and natural tooth abutments in periodontally treated patients has been reported by few studies, with controversial results. The objective of this study was to evaluate long-term (15 years) complications of abutment teeth and dental implants in periodontally treated patients, rehabilitated with full arch telescopic-retained retrievable prostheses (TRP)s vs. full arch fixed prostheses (FP)s supported by teeth and implants. After active periodontal therapy (non-surgical and surgical), and implant placement (replacement of hopeless teeth and in edentulous sites), 18 patients were rehabilitated in both dental arches with full arch TRPs, and 17 patients were rehabilitated with full arch FPs. Patients were annually recalled for technical and/or biological complications monitoring. During the 15-year observation period, 29 of 164 (17.6%) implants failed in the TRP group and 26 of 152 (17.1 %) implants in the FP group. Due to progression of periodontal disease, endo-perio untreatable lesion and caries, 22 of 233 abutment teeth were extracted (8.1) % in the TRP group and 23 of 221 (10.4%) abutment teeth were extracted in the FP group. Difference in implant failures and abutment teeth loss between the two groups were found not statistically significant (p >0.05). Poisson regression analysis showed that in both groups, factors such as smoking habits, FMBS>20, number of pockets >6 mm, mean bone loss, and bone loss/age, contribute to tooth and implant failure (p<0.05). In this clinical study, in periodontally treated patients, full arch telescopic-retained retrievable prostheses, and full arch fixed prosthesis, supported by teeth and implants presented comparable long-term results of tooth loss and implant failure, if regular periodontal therapy is implemented

    One-stage laser-microtextured implants immediately placed in the inter-radicular septum of molar fresh extraction sockets associated with GBR technique. A case series study

    Get PDF
    The outcome of one-stage trans-mucosal immediate implants with simultaneous guided bone regeneration (GBR) technique has become highly predictable. Furthermore, when this approach is performed to place one-stage implants into the inter-radicular septum of fresh extraction sockets in the molar region, the risk of incorrect emergence profile and off-angle loading is reduced. The aim of the present study was to clinically evaluate the horizontal hard and soft tissue changes, and radiographically the vertical socket walls remodeling, and the early peri-implant marginal bone loss (EMBL) following the placement of immediate one-stage implants in the inter-radicular septum of molar fresh extraction sockets, associated with a collagen membrane. Twenty patients were selected to receive a one-stage implant with laser-microtextured collar surface into the inter-radicular septum of a fresh molar extraction sockets, associated with a simultaneous placement of a collagen membrane. Intraoral radiographs and model casts were used for the evaluation. Correlation between the amount of the keratinized tissue thickness (KTT) with EMBL was also analyzed. After 4 months, the vertical radiographic mesial and distal EMBL around implants was of 0.06 ±0.01 mm and 0.04±0.02 mm, respectively, with no statistically significant difference between T0 and T1 (P >0.05). No statistical differences were found also for each radiographic measure used for the examination of implant sites vertical bone changes (p >0.05). Clinically, horizontal changes of the bucco-lingual central width were found statistically significant (p0.05). In addition, no statistically significant correlation between EMBL and the amount of KTT was found (P >0.05). Results suggest that the immediate placement of one-stage laser-microtextured implants could provide advantages in preserving the extraction socket?s hard and soft tissue remodeling, and the peri-implant marginal bone level before the prosthetic loading

    Detection of bone defects using CBCT exam in an Italian population

    Get PDF
    Background. The aim of this study was to evaluate the in vivo incidence and the location of fenestrations in a young Italian population by using CBCT. Materials and Methods. Fifty patients who had previously performed CBCT for planning third molar extraction or orthodontic therapy were selected for the study. No previous dental treatment had been performed on these patients. Overall, 1,395 teeth were evaluated. Root fenestrations were identified according to the definition of Davies and the American Association of Endodontists. Data was collected and statistically analyzed. Results. Fenestrations were observed in 159 teeth out of 1,395 (11% of teeth). In the lower jaw, we found 68 fenestrations (5%) and 91 in the maxilla (6,5%). Incisors were the teeth with the highest incidence of fenestrations. Conclusion.The relative common finding (11%)of fenestration supports the need for CBCT exams before any surgical/implant treatment to avoid complications related to the initial presence of fenestrations. CBCT was found to be an effective and convenient tool for diagnosing fenestration

    Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments : Waveone gold vs Edgeone fire

    Get PDF
    Aim of this study is to investigate the cyclic fatigue resistance of the Gold treated WaveOne Gold and the Firewire treated EdgeOne Fire instruments. The null hypotesis was that there were no differences between the lifespan of Gold treated and FireWire treated instruments when subjected to cyclic fatigue tests. 40 new NiTi instruments with a length of 25 mm were tested: 20 Wave One Gold Medium (WOG), tip size 35 and variable taper (Dentsply Maillefer, Ballaigues, Switzerland) and 20 Edge One Fire (EOF) (EdgeEndo, Albuquerque, New Mexico) tip size 35 and the same variable taper. A mobile support for the electric handpiece and a stainless-steel block containing the artificial canals were used. The same artificial root canal with a 90 degrees angle of curvature and 2 mm radius of curvature was used for all the tested instruments and the WOG counter-clock wise reciprocating motion with an engaging angle of 150° and a disengaging angle of 30° at 300 rpm, was selected for the test. All instruments were inserted at the same length (18mm) and then rotated in the same reciprocating motion until fracture occurred: the time was stopped as soon as the fracture was visible and video-recorded with a 1/100 sec chronometer. Differences among groups were statistically evaluated with an analysis of variance test ANOVA (significance level was set at p<0.05). Mean values of time to fracture (TtF) for EOF instruments were 28,00 seconds (SD +/- 2,64) and for WOG instruments were 14,67 seconds (SD +/- 2,41). Statistical analysis found significant differences between the TtF of the two instruments (p<0,05). Firewire instruments resulted to be about two times more resistant to cyclic fatigue when compared with identical instruments made with Gold treatment

    Potential of Operative Torque in Evaluating NiTi Instruments

    Get PDF
    The role of nickel-titanium (NiTi) in the production of endodontic instruments increased in the last few decades; therefore, the way of evaluation of its performance increased as well. Nowadays, there are several ways to evaluate NiTi instruments, divided into static and dynamic tests. The static ones are cyclic fatigue tests, torsional resistance tests, flexibility, and cutting efficiency tests. These methodologies have been deeply used to evaluate some of the metallurgical properties of the instruments on the market. Up-to-date, we know very well the behavior of NiTi under static conditions, but these knowledges are too fragmented to be relevant for understanding and evaluating the complexities of intracanal instrumentation. Starting from the purpose to introduce the variable of movement in the testing procedure, some dynamic tests have been proposed, such as dynamic cyclic fatigue test.1,2 Although these kinds of studies were capable of evaluating more precisely the behavior of rotary instruments inside the root canal, they could not take into account, at this moment, the complexities of stresses that instruments undergo during the shaping procedure.3-5 Therefore, some of these tests are not accepted anymore by the scientific community and on the contrary they do not help the general practitioner to orientate in the large amount of rotary instruments present on the market.6 This tends to withdraw the general dentistry from the scientific literature, wearing a groove between the practice and the science.7 Starting from these ideas, in the last couple of years some authors started to think the proper way to real-time evaluation of the performance of NiTi rotary instruments inside the root canal. To do so, a countable and repeatable measurement of instrument's developed stresses was needed. Setzer and Böhme8 first used the torque generated by Revo-S, Vortex, and ProFile to evaluate their performance during instrumentation. The so-called "operative torque" is the summation of torque generated in each point of the instrument during its simultaneous movement around its own axis and up and down inside the canal. The recorded values are influenced by both torsional and flexural stresses, becoming this way a reliable method to analyze, evaluate, and compare the performance of NiTi instruments inside the root canal.9 This methodology is applicable for not only in vitro but also in vivo measurement, as demonstrated by Gambarini et al.10 The main drawback of this kind of evaluation is the not well-determined correlation between the torsional and the flexural stresses; therefore, it is still unpredictable how each influence the other. In conclusion, the potential of real-time torque measurement is wide and still unexplored, but further studies are needed to better understand how torque is developed inside the root canal

    Symmetry of root and root canal morphology of mandibular incisors : a cone-beam computed tomography study in vivo

    Get PDF
    Background: Aim of this study was to analyze the root canal configuration in mandibular central and lateral incisors in vivo using cone-beam computed tomography (CBCT) imaging. Material and Methods: A total of 487 mandibular central incisors and 491 mandibular lateral incisors from 250 patients were examined using CBCT imaging, previously taken for diagnosis and treatment. The number of roots, root canal system configuration, presence of apical confluences, distance between confluences and radiographic root end, symmetry between left and right elements were recorded and statistically analyzed. Results: All the examined teeth presented only one root. No significant differences were found between the prevalence of two root canals in mandibular central incisors (219 teeth, 45%) compared to lateral incisors (211 teeth, 43%). Conclusions: The percentage of Vertucci type II configuration was higher than expected, being more frequent than type III. Type I was the prevalent, while other configurations were present but rare

    Surgical and orthodontic rapid palatal expansion in adults using a modified palatal partial osteotomy technique (ppot) : technique description and clinical experience

    Get PDF
    Transversal hypoplasia of the upper maxilla is a frequent condition between malocclusions. The rapid maxillary expansion (RME) is an already consolidated technique for these types of defects. This case report analyzes the outcome of a novel surgical technique that we named TOPP (Partial Palatal osteotomy technique) aiming to provide scientifically proven data over the percentage of relapse and the long-term stability of this type of surgical assisted palatal expansion. A 24 year old male patient with a hyperdivergent class III, presenting the absence of 1.1 due to a teenage trauma and a transversal contraction of the upper arch was selected for the surgery. The mucoperiosteal flap was performed at a palatal level with a paramarginal arch shape (from region 1.4 to 2.4) due to preserve the nasal-incisal vascular bundle and the mucoperiosteum was detached from the floor of the nose. A horizontal osteotomy was performed at 4-5 mm above the roots apexes; a sagittal osteotomy in a posterior direction was done at the level of the midline to divide the mesiopalatine suture and separate the maxilla in two halves. The only bony attachment that remained was represented by the perpendicular lamina of the palatal bone. The TOPP technique showed that it is possible to have a better control of both the intercanine and intermolar expansion, that is more difficult in the case of a conventional SARME. Other goals were a greater view and access to the site and the reduction of the risk of damaging the palatine fibromucosa. The incision of the archform paramarginal flap improves certainly the conditions of the palatal fibromucosa in the post operative and allows the reduction of the soft tissues? elastic return

    A comparative study of mechanical resistance of two reciprocating files

    Get PDF
    To evaluate the cyclic fatigue resistance of two different Nickel-Titanium instruments, Reziflow (Komet, Brasseler GmbH & Co., Lemgo, Germany) and WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland). Two groups of 20 different NiTi endodontic instruments of identical tip size of 0.25 mm were tested; Reziflow and Wave-One Gold primary. Cyclic fatigue testing was performed in a stainless steel simulated root canal manufactured by reproducing the instrument?s size and taper. A simulated root canal with a 90 degrees angle of curvature and 5 mm radius of curvature was constructed for the instruments tested. The centre of the curvature was 5 mm from the tip of the instrument and the curved segment of the canal was approximately 5 mm in length. Both the instruments were used in the same preset program specific for the WaveOne instruments. Each instrument was rotated until fracture occurred and the time to fracture (TtF) and the length of the fractured fragment were recorded. Means and standard deviations of TtF and fragment length were calculated and data were subjected to statical analysis (P0.05) in the mean length of the fractured fragments between the instruments. Rezifllow instruments were associated with a significantly higher cyclic fatigue resistance than WaveOne Gold instruments
    • …
    corecore