149 research outputs found

    The behavior of novel hydrophilic composite bone cements in simulated body fluids

    Get PDF
    Composite bone cements were formulated with bioactive glass (MgOOSiO2O3CaO ! P2O5) as the filler and hydrophilic matrix. The matrix was composed of a starch/cellulose acetate blend (SCA) as the solid component and a mixture of methylmethacrylate/acrylic acid (MMA/AA) as the liquid component. The curing parameters, mechanical properties, and bioactive behavior of these composite cements were determined. The addition of up to 30 wt % of glass improved both compressive modulus and yield strength and kept the maximum curing temperature at the same value presented by a typical acrylic-based commercial formulation. The lack of a strongly bonded interface (because no coupling agent was used) had important effects on the swelling and mechanical properties of the novel bone cements. However, bone cements containing AA did not show a bioactive behavior, because of the deleterious effect of this monomer on the calcium phosphate precipitation on the polymeric surfaces. Formulations without AA were prepared with MMA or 2-hydroxyethyl methacrylate (HEMA) as the liquid component. Only these formulations could form an apatite-like layer on their surface. These systems, therefore, are very promising: They are bioactive, hydrophilic, partially degradable, and present interesting mechanical properties. This combination of properties could facilitate the release of bioactive agents from the cement, allow bone ingrowth in the cement, and induce a press-fitting effect, improving the interfaces with both the prosthesis and the bone

    The in vitro bioactivity of two novel hydrophilic, partially degradable bone cements

    Get PDF
    Composite bone cements were prepared with bioactive glasses (MgO–SiO2–3CaO Æ P2O5) of different reactivities. The matrix of these so-called hydrophilic, partially degradable and bioactive cements was composed of a starch/cellulose acetate blend and poly(2-hydroxyethyl methacrylate). The addition of 30 wt.% of glasses to this system made them bioactive in acellular medium: a dense apatite layer formed on the surface after 7 days of immersion in simulated body fluid. This was demonstrated both by microscopic and infrared spectroscopic techniques. The composition of the glass and, consequently, its structure was found to have important effects on the rate of the apatite formation. The combination of reactivity obtained by one formulation with the hydrophilic and degradable character of these cements makes them a very promising alternative to conventional acrylic bone cements, by allowing a better stabilization of the implant and a stronger adhesion to the bone

    Knockdown resistance mutations predict DDT resistance and pyrethroid tolerance in the visceral leishmaniasis vector Phlebotomus argentipes

    Get PDF
    BACKGROUND:Indoor residual spraying (IRS) with DDT has been the primary strategy for control of the visceral leishmaniasis (VL) vector Phlebotomus argentipes in India but efficacy may be compromised by resistance. Synthetic pyrethroids are now being introduced for IRS, but with a shared target site, the para voltage-gated sodium channel (VGSC), mutations affecting both insecticide classes could provide cross-resistance and represent a threat to sustainable IRS-based disease control. METHODOLOGY/PRINCIPAL FINDINGS:A region of the Vgsc gene was sequenced in P. argentipes from the VL hotspot of Bihar, India. Two knockdown resistance (kdr) mutations were detected at codon 1014 (L1014F and L1014S), each common in mosquitoes, but previously unknown in phlebotomines. Both kdr mutations appear largely recessive, but as homozygotes (especially 1014F/F) or as 1014F/S heterozygotes exert a strong effect on DDT resistance, and significantly predict survivorship to class II pyrethroids in short-duration bioassays. The mutations are present at high frequency in wild P. argentipes populations from Bihar, with 1014F significantly more common in higher VL areas. CONCLUSIONS/SIGNIFICANCE:The Vgsc mutations detected appear to be a primary mechanism underlying DDT resistance in P. argentipes and a contributory factor in reduced pyrethroid susceptibility, suggesting a potential impact if P. argentipes are subjected to suboptimal levels of pyrethroid exposure, or additional resistance mechanisms evolve. The assays to detect kdr frequency changes provide a sensitive, high-throughput monitoring tool to detecting spatial and temporal variation in resistance in P. argentipes

    Poly(ethylmethacrylate-co-diethylaminoethyl acrylate) coating improves endothelial re-population, bio-mechanical and anti-thrombogenic properties of decellularized carotid arteries for blood vessel replacement

    Get PDF
    Decellularized vascular scaffolds are promising materials for vessel replacements. However, despite the natural origin of decellularized vessels, issues such as biomechanical incompatibility, immunogenicity risks and the hazards of thrombus formation, still need to be addressed. In this study, we coated decellularized vessels obtained from porcine carotid arteries with poly (ethylmethacrylate-co-diethylaminoethylacrylate) (8g7) with the purpose of improving endothelial coverage and minimizing platelet attachment while enhancing the mechanical properties of the decellularized vascular scaffolds. The polymer facilitated binding of endothelial cells (ECs) with high affinity and also induced endothelial cell capillary tube formation. In addition, platelets showed reduced adhesion on the polymer under flow conditions. Moreover, the coating of the decellularized arteries improved biomechanical properties by increasing its tensile strength and load. In addition, after 5 days in culture, ECs seeded on the luminal surface of 8g7-coated decellularized arteries showed good regeneration of the endothelium. Overall, this study shows that polymer coating of decellularized vessels provides a new strategy to improve re-endothelialization of vascular grafts, maintaining or enhancing mechanical properties while reducing the risk of thrombogenesis. These results could have potential applications in improving tissue-engineered vascular grafts for cardiovascular therapies with small caliber vessels

    A Critical Review of Biomarkers Used for Monitoring Human Exposure to Lead: Advantages, Limitations, and Future Needs

    Get PDF
    Lead concentration in whole blood (BPb) is the primary biomarker used to monitor exposure to this metallic element. The U.S. Centers for Disease Control and Prevention and the World Health Organization define a BPb of 10 μg/dL (0.48 μmol/L) as the threshold of concern in young children. However, recent studies have reported the possibility of adverse health effects, including intellectual impairment in young children, at BPb levels < 10 μg/dL, suggesting that there is no safe level of exposure. It appears impossible to differentiate between low-level chronic Pb exposure and a high-level short Pb exposure based on a single BPb measurement; therefore, serial BPb measurements offer a better estimation of possible health outcomes. The difficulty in assessing the exact nature of Pb exposure is dependent not so much on problems with current analytical methodologies, but rather on the complex toxicokinetics of Pb within various body compartments (i.e., cycling of Pb between bone, blood, and soft tissues). If we are to differentiate more effectively between Pb stored in the body for years and Pb from recent exposure, information on other biomarkers of exposure may be needed. None of the current biomarkers of internal Pb dose have yet been accepted by the scientific community as a reliable substitute for a BPb measurement. This review focuses on the limitations of biomarkers of Pb exposure and the need to improve the accuracy of their measurement. We present here only the traditional analytical protocols in current use, and we attempt to assess the influence of confounding variables on BPb levels. Finally, we discuss the interpretation of BPb data with respect to both external and endogenous Pb exposure, past or recent exposure, as well as the significance of Pb determinations in human specimens including hair, nails, saliva, bone, blood (plasma, whole blood), urine, feces, and exfoliated teeth

    A case-only study to identify genetic modifiers of breast cancer risk for BRCA1/BRCA2 mutation carriers

    Get PDF
    Breast cancer (BC) risk for BRCA1 and BRCA2 mutation carriers varies by genetic and familial factors. About 50 common variants have been shown to modify BC risk for mutation carriers. All but three, were identified in general population studies. Other mutation carrier-specific susceptibility variants may exist but studies of mutation carriers have so far been underpowered. We conduct a novel case-only genome-wide association study comparing genotype frequencies between 60,212 general population BC cases and 13,007 cases with BRCA1 or BRCA2 mutations. We identify robust novel associations for 2 variants with BC for BRCA1 and 3 for BRCA2 mutation carriers, P &lt; 10−8, at 5 loci, which are not associated with risk in the general population. They include rs60882887 at 11p11.2 where MADD, SP11 and EIF1, genes previously implicated in BC biology, are predicted as potential targets. These findings will contribute towards customising BC polygenic risk scores for BRCA1 and BRCA2 mutation carriers

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Use of anticoagulants and antiplatelet agents in stable outpatients with coronary artery disease and atrial fibrillation. International CLARIFY registry

    Get PDF
    corecore