65 research outputs found

    Ink-jet printout of radiographs on transparent film and glossy paper versus monitor display: an ROC analysis

    Get PDF
    The aim of this study was to compare the depiction ability of small grayscale contrasts in ink-jet printouts of digital radiographs on different print media with CRT monitor. A CCD-based digital cephalometric image of a stepless aluminum wedge containing 50 bur holes of different depth was cut into 100 isometric images. Each image was printed on glossy paper and on transparent film by means of a high-resolution desktop inkjet printer at specific settings. The printed images were viewed under standardized conditions, and the perceptibility of the bur holes was evaluated and compared to the perceptibility on a 17-in CRT monitor. Thirty observers stated their blinded decision on a five-point confidence scale. Areas (Az) under receiver operating characteristics curves were calculated and compared using the pair wise sign tests. Overall agreement was estimated using Cohen's kappa device and observer bias using McNemar's test. Glossy paper prints and monitor display revealed significantly higher (P < 0.001) average Az values (0.83) compared to prints on transparent film (0.79), which was caused by higher sensitivity. Specificity was similar for all modalities. The sensitivity was dependent on the mean gray scale values for the transparent fil

    The influence of ambient lighting on the detection of small contrast elements in digital dental radiographs

    Get PDF
    Objectives: The aim of this study was to evaluate the effect of ambient light on the detection of contrast elements in digital dental radiographs. Materials and methods: A high-contrast standardized digital radiograph of an aluminum step wedge containing 32 boreholes of different depth was cut into 40 isometric images. Images were presented at random on a 17-in cathode ray tube (CRT) monitor at different ambient background illuminations of 0, 50, 200, and 500lx. Twenty observers stated twice their blinded decision whether or not they could perceive a dark spot on a five-point confidence scale. Areas (Az) under receiver operating characteristic curves were calculated and compared between the four different ambient illuminations using the Friedman test. Statistical significance was set at p < 0.05. Overall agreement was estimated determining the intraclass correlation coefficient. Results: The Az values (0.735 for 0lx, 0.728 for 50lx, 0.735 for 200lx, and 0.788 for 500lx) did not significantly differ (p = 0.796) between the four ambient lighting levels. Conclusions: The detection of small contrast features in digital dental radiographs on a CRT monitor seems to be comparable over a wide range of ambient background illumination. Clinical relevance: The ambient light in dental offices of <500lx may not negatively impact the diagnostic performance of digital dental radiograph

    Increased expression of vascular endothelin type B and angiotensin type 1 receptors in patients with ischemic heart disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Endothelin-1 and angiotensin II are strong vasoconstrictors. Patients with ischemic heart disease have elevated plasma levels of endothelin-1 and angiotensin II and show increased vascular tone. The aim of the present study was to examine the endothelin and angiotensin II receptor expression in subcutaneous arteries from patients with different degrees of ischemic heart disease.</p> <p>Methods</p> <p>Subcutaneous arteries were obtained, by biopsy from the abdomen, from patients undergoing coronary artery bypass graft (CABG) surgery because of ischemic heart disease (n = 15), patients with angina pectoris without established myocardial infarction (n = 15) and matched cardiovascular healthy controls (n = 15). Endothelin type A (ET<sub>A</sub>) and type B (ET<sub>B</sub>), and angiotensin type 1 (AT<sub>1</sub>) and type 2 (AT<sub>2</sub>) receptors expression and function were examined using immunohistochemistry, Western blot and <it>in vitro </it>pharmacology.</p> <p>Results</p> <p>ET<sub>A </sub>and, to a lesser extent, ET<sub>B </sub>receptor staining was observed in the healthy vascular smooth muscle cells. The level of ET<sub>B </sub>receptor expression was higher in patients undergoing CABG surgery (250% ± 23%; P < 0.05) and in the patients with angina pectoris (199% ± 6%; P < 0.05), than in the healthy controls (100% ± 28%). The data was confirmed by Western blotting. Arteries from CABG patients showed increased vasoconstriction upon administration of the selective ET<sub>B </sub>receptor agonist sarafotoxin S6c, compared to healthy controls (P < 0.05). No such difference was found for the ET<sub>A </sub>receptors. AT<sub>1 </sub>and, to a lesser extent, AT<sub>2 </sub>receptor immunostaining was seen in the vascular smooth muscle cells. The level of AT<sub>1 </sub>receptor expression was higher in both the angina pectoris (128% ± 25%; P < 0.05) and in the CABG patients (203% ± 41%; P < 0.05), as compared to the healthy controls (100% ± 25%). The increased AT<sub>1 </sub>receptor expression was confirmed by Western blotting. Myograph experiment did however not show any change in vasoconstriction to angiotensin II in CABG patients compared to healthy controls (P = n.s).</p> <p>Conclusion</p> <p>The results demonstrate, for the first time, upregulation of ET<sub>B </sub>and AT<sub>1 </sub>receptors in vascular smooth muscle cells in ischemic heart disease. These receptors may play a role in the pathophysiology of ischemic heart disease and could provide important targets for pharmaceutical interventions.</p

    Cigarette Smoke Upregulates Rat Coronary Artery Endothelin Receptors In Vivo

    Get PDF
    Background: Cigarette smoking is a strong cardiovascular risk factor and endothelin (ET) receptors are related to coronary artery diseases. The present study established an in vivo secondhand smoke (SHS) exposure model and investigated the hypothesis that cigarette smoke induces ET receptor upregulation in rat coronary arteries and its possible underlying mechanisms. Methodology/Principal Findings: Rats were exposed to SHS for 200 min daily for 8 weeks. The coronary arteries were isolated and examined. The vasoconstriction was studied by a sensitive myograph. The expression of mRNA and protein for receptors was examined by real-time PCR, Western blot and immunofluorescence. Compared to fresh air exposure, SHS increased contractile responses mediated by endothelin type A (ETA) and type B (ETB) receptors in coronary arteries. In parallel, the expression of mRNA and protein for ETA and ETB receptors of smoke exposed rats were higher than that of animals exposed to fresh air, suggesting that SHS upregulates ET A and ET B receptors in coronary arteries in vivo. Immunofluorescence staining showed that the enhanced receptor expression was localized to the smooth muscle cells of coronary arteries. The protein levels of phosphorylated (p)-Raf-1 and p-ERK1/2 in smoke exposed rats were significantly higher than in control rats, demonstrating that SHS induces the activation of the Raf/ERK/MAPK pathway. Treatment with Raf-1 inhibitor GW5074 suppressed SHS-induced enhanced contraction mediated by ET A receptors, and inhibited th

    Up-regulation of endothelin type B receptors in the human internal mammary artery in culture is dependent on protein kinase C and mitogen-activated kinase signaling pathways

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Up-regulation of vascular endothelin type B (ET<sub>B</sub>) receptors is implicated in the pathogenesis of cardiovascular disease. Culture of intact arteries has been shown to induce similar receptor alterations and has therefore been suggested as a suitable method for, <it>ex vivo</it>, in detail delineation of the regulation of endothelin receptors. We hypothesize that mitogen-activated kinases (MAPK) and protein kinase C (PKC) are involved in the regulation of endothelin ET<sub>B </sub>receptors in human internal mammary arteries.</p> <p>Methods</p> <p>Human internal mammary arteries were obtained during coronary artery bypass graft surgery and were studied before and after 24 hours of organ culture, using <it>in vitro </it>pharmacology, real time PCR and Western blot techniques. Sarafotoxin 6c and endothelin-1 were used to examine the endothelin ET<sub>A </sub>and ET<sub>B </sub>receptor effects, respectively. The involvement of PKC and MAPK in the endothelin receptor regulation was examined by culture in the presence of antagonists.</p> <p>Results</p> <p>The endohtelin-1-induced contraction (after endothelin ET<sub>B </sub>receptor desensitization) and the endothelin ET<sub>A </sub>receptor mRNA expression levels were not altered by culture. The sarafotoxin 6c contraction, endothelin ET<sub>B </sub>receptor protein and mRNA expression levels were increased after organ culture. This increase was antagonized by; (1) PKC inhibitors (10 μM bisindolylmaleimide I and 10 μM Ro-32-0432), and (2) inhibitors of the p38, extracellular signal related kinases 1 and 2 (ERK1/2) and C-jun terminal kinase (JNK) MAPK pathways (10 μM SB203580, 10 μM PD98059 and 10 μM SP600125, respectively).</p> <p>Conclusion</p> <p>In conclusion, PKC and MAPK seem to be involved in the up-regulation of endothelin ET<sub>B </sub>receptor expression in human internal mammary arteries. Inhibiting these intracellular signal transduction pathways may provide a future therapeutic target for hindering the development of vascular endothelin ET<sub>B </sub>receptor changes in cardiovascular disease.</p

    Endothelium-derived endothelin-1

    Get PDF
    One year after the revelation by Dr. Furchgott in 1980 that the endothelium was obligatory for acetylcholine to relax isolated arteries, it was clearly shown that the endothelium could also promote contraction. In 1988, Dr. Yanagisawa’s group identified endothelin-1 (ET-1) as the first endothelium-derived contracting factor. The circulating levels of this short (21-amino acid) peptide were quickly determined in humans, and it was reported that, in most cardiovascular diseases, circulating levels of ET-1 were increased, and ET-1 was then tagged as “a bad guy.” The discovery of two receptor subtypes in 1990, ET(A) and ET(B), permitted optimization of the first dual ET-1 receptor antagonist in 1993 by Dr. Clozel’s team, who entered clinical development with bosentan, which was offered to patients with pulmonary arterial hypertension in 2001. The revelation of Dr. Furchgott opened a Pandora’s box with ET-1 as one of the actors. In this brief review, we will discuss the physiological and pathophysiological role of endothelium-derived ET-1 focusing on the regulation of the vascular tone, and as much as possible in humans. The coronary bed will be used as a running example in this review because it is the most susceptible to endothelial dysfunction, but references to the cerebral and renal circulation will also be made. Many of the cardiovascular complications associated with aging and cardiovascular risk factors are initially attributable, at least in part, to endothelial dysfunction, particularly dysregulation of the vascular function associated with an imbalance in the close interdependence of nitric oxide and ET-1

    Prevalence and correlation with sex, age, and dental status of bone apposition at the mandibular angle and radiographic alterations of the temporomandibular joints: a retrospective observational study in an adult Swiss population

    No full text
    Abstract Background The purpose of this study was to determine the prevalence of radiographic changes in the mandibular angle (bone apposition) and osseous alterations in the temporomandibular joints (TMJs) in the adult population of Switzerland. In addition, the study intended to investigate possible correlations between the two sites of contour bone changes (mandibular angle and TMJ) and to analyze various patient-related factors, including sex, age, dental status, and medical history. Methods Panoramic radiographs of 600 patients distributed into six age groups (283 females, 317 males, aged 20 to 79 years) were included to evaluate radiographic changes. The bone in the mandibular angle region and the shape of the condylar heads were examined for contour changes (bone apposition at the jaw angles and osseous changes of the TMJs). General estimating equations, binormal tests, and chi-squared tests were used for statistical analysis. Results Approximately half of the mandibular angles (47.8%) showed bone apposition, mostly bilateral. TMJ alterations were less common (27%), often unilateral, with flattening being the most frequent finding. No significant correlation was found between the two sites. Bone apposition at the mandibular angle showed a significant male predominance, whereas TMJ changes did not differ by sex. Alterations in both sites increased with age, and were not related to dental status or analgesic use. Conclusions Bone apposition at the mandibular angle should be interpreted as part of the natural functional adaptation of the bone associated with aging. Assuming that parafunctional habits may influence the development and progression of alterations in the mandibular angle or TMJs, the presence of radiographic changes in these areas should prompt dental clinicians to investigate further in this direction. Trial registration The study was approved by the Swiss Association of Research Ethics Committees (swissethics), BASEC reference number: 2020–00963 (25.05.2020)

    Tilting the jaw to improve the image quality or to reduce the dose in cone-beam computed tomography

    No full text
    The image quality in cone-beam computed tomography (CBCT) should be improved tilting the mandible that contains two dental titanium implants, within the relevant range of motion
    corecore