66 research outputs found

    Preoperative Red Cell Distribution Width and 30-day mortality in older patients undergoing non-cardiac surgery: a retrospective cohort observational study

    Get PDF
    Increased red cell distribution width (RDW) is associated with poorer outcomes in various patient populations. We investigated the association between preoperative RDW and anaemia on 30-day postoperative mortality among elderly patients undergoing non-cardiac surgery. Medical records of 24,579 patients aged 65 and older who underwent surgery under anaesthesia between 1 January 2012 and 31 October 2016 were retrospectively analysed. Patients who died within 30 days had higher median RDW (15.0%) than those who were alive (13.4%). Based on multivariate logistic regression, in our cohort of elderly patients undergoing non-cardiac surgery, moderate/severe preoperative anaemia (aOR 1.61, p = 0.04) and high preoperative RDW levels in the 3rd quartile (>13.4% and ≤14.3%) and 4th quartile (>14.3%) were significantly associated with increased odds of 30-day mortality - (aOR 2.12, p = 0.02) and (aOR 2.85, p = 0.001) respectively, after adjusting for the effects of transfusion, surgical severity, priority of surgery, and comorbidities. Patients with high RDW, defined as >15.7% (90th centile), and preoperative anaemia have higher odds of 30-day mortality compared to patients with anaemia and normal RDW. Thus, preoperative RDW independently increases risk of 30-day postoperative mortality, and future risk stratification strategies should include RDW as a factor

    Clinical Usefulness of Measuring Red Blood Cell Distribution Width in Patients with Hepatitis B

    Get PDF
    BACKGROUND: Red blood cell distribution width (RDW), an automated measure of red blood cell size heterogeneity (e.g., anisocytosis) that is largely overlooked, is a newly recognized risk marker in patients with cardiovascular diseases, but its role in persistent viral infection has not been well-defined. The present study was designed to investigate the association between RDW values and different disease states in hepatitis B virus (HBV)-infected patients. In addition, we analyzed whether RDW is associated with mortality in the HBV-infected patients. METHODOLOGY/PRINCIPAL FINDINGS: One hundred and twenty-three patients, including 16 with acute hepatitis B (AHB), 61 with chronic hepatitis B (CHB), and 46 with chronic severe hepatitis B (CSHB), and 48 healthy controls were enrolled. In all subjects, a blood sample was collected at admission to examine liver function, renal function, international normalized ratio and routine hematological testing. All patients were followed up for at least 4 months. A total of 10 clinical chemistry, hematology, and biochemical variables were analyzed for possible association with outcomes by using Cox proportional hazards and multiple regression models. RDW values at admission in patients with CSHB (18.30±3.11%, P<0.001), CHB (16.37±2.43%, P<0.001) and AHB (14.38±1.72%, P<0.05) were significantly higher than those in healthy controls (13.03±1.33%). Increased RDW values were clinically associated with severe liver disease and increased 3-month mortality rate. Multivariate analysis demonstrated that RDW values and the model for end-stage liver disease score were independent predictors for mortality (both P<0.001). CONCLUSION: RDW values are significantly increased in patients with hepatitis B and associated with its severity. Moreover, RDW values are an independent predicting factor for the 3-month mortality rate in patients with hepatitis B

    EVALUATION OF THE RESAZURIN REDUCTION ONE-HOUR TEST FOR GRADING MILK INTENDED FOR MANUFACTURING PURPOSES1,2

    Full text link
    Randomly selected dairy farms in three widely separated geographical locations, producing milk intended for manufacturing purposes, were sampled once each season of the year. Samples were analyzed by Standard Plate Count (SPC-32 C.), resazurin reduction test (RRT-5 P 7/4) and resazurin reduction 1 hr test (RRT-1 hr). Correlation between SPC and RRT-1 hr was 0.742 and between SPC and RRT-5 P 7/4, −0.777. Application of ADMI/EMA standards or calculated RRT-1 hr standards resulted in a quality distribution that differed from the distribution given by SPC or RRT. With the proposed RRT-1 hr test, a combination of the ADMI/EMA and the calculated standard levels, evaluation of the quality of can and of farm bulk tank supplies in various geographical locations was similar to the evaluation given by either SPC or RRT. The RRT-1 hr test was judged to be as useful as RRT-5 P 7/4, DMCC, SPC, or MBRT in assessing the bacteriological quality of various types of milk supplies, and has the advantage of being faster. For reliable results, standard illumination must be used.</jats:p
    corecore