16 research outputs found

    Force-Controlled Balance Perturbations Associated with Falls in Older People: A Prospective Cohort Study

    Get PDF
    Balance recovery from an unpredictable postural perturbation can be a challenging task for many older people and poor recovery could contribute to their risk of falls. This study examined associations between responses to unpredictable perturbations and fall risk in older people. 242 older adults (80.064.4 years) underwent assessments of stepping responses to multi-directional force-controlled waist-pull perturbations. Participants returned monthly falls calendars for the subsequent 12 months. Future falls were associated with lower force thresholds for stepping in the posterior and lateral but not anterior directions. Those with lower posterior force thresholds for stepping were 68% more likely to fall at home than those with higher force thresholds for stepping. These results suggest that amount of force that can be withstood following an unpredictable balance perturbation predicts future falls in community-dwelling older adults. Perturbations in the posterior direction best discriminated between future fallers and non-fallers

    Freezing of gait and fall detection in Parkinson’s disease using wearable sensors:a systematic review

    Get PDF
    Despite the large number of studies that have investigated the use of wearable sensors to detect gait disturbances such as Freezing of gait (FOG) and falls, there is little consensus regarding appropriate methodologies for how to optimally apply such devices. Here, an overview of the use of wearable systems to assess FOG and falls in Parkinson’s disease (PD) and validation performance is presented. A systematic search in the PubMed and Web of Science databases was performed using a group of concept key words. The final search was performed in January 2017, and articles were selected based upon a set of eligibility criteria. In total, 27 articles were selected. Of those, 23 related to FOG and 4 to falls. FOG studies were performed in either laboratory or home settings, with sample sizes ranging from 1 PD up to 48 PD presenting Hoehn and Yahr stage from 2 to 4. The shin was the most common sensor location and accelerometer was the most frequently used sensor type. Validity measures ranged from 73–100% for sensitivity and 67–100% for specificity. Falls and fall risk studies were all home-based, including samples sizes of 1 PD up to 107 PD, mostly using one sensor containing accelerometers, worn at various body locations. Despite the promising validation initiatives reported in these studies, they were all performed in relatively small sample sizes, and there was a significant variability in outcomes measured and results reported. Given these limitations, the validation of sensor-derived assessments of PD features would benefit from more focused research efforts, increased collaboration among researchers, aligning data collection protocols, and sharing data sets

    Wrist-Worn Wearables Based on Force Myography: On the Significance of User Anthropometry

    Get PDF
    Background Force myography (FMG) is a non-invasive technology used to track functional movements and hand gestures by sensing volumetric changes in the limbs caused by muscle contraction. Force transmission through tissue implies that differences in tissue mechanics and/or architecture might impact FMG signal acquisition and the accuracy of gesture classifier models. The aim of this study is to identify if and how user anthropometry affects the quality of FMG signal acquisition and the performance of machine learning models trained to classify different hand and wrist gestures based on that data. Methods Wrist and forearm anthropometric measures were collected from a total of 21 volunteers aged between 22 and 82 years old. Participants performed a set of tasks while wearing a custom-designed FMG band. Primary outcome measure was the Spearman’s correlation coefficient (R) between the anthropometric measures and FMG signal quality/ML model performance. Results Results demonstrated moderate (0.3 ≤|R| < 0.67) and strong (0.67 ≤ |R|) relationships for ratio of skinfold thickness to forearm circumference, grip strength and ratio of wrist to forearm circumference. These anthropometric features contributed to 23–30% of the variability in FMG signal acquisition and as much as 50% of the variability in classification accuracy for single gestures. Conclusions Increased grip strength, larger forearm girth, and smaller skinfold-to-forearm circumference ratio improve signal quality and gesture classification accuracy

    Central adaptation to repeated galvanic vestibular stimulation: Implications for pre-flight astronaut training

    No full text
    Moore, ST ORCiD: 0000-0003-3995-4912Healthy subjects (N=10) were exposed to 10-min cumulative pseudorandom bilateral bipolar Galvanic vestibular stimulation (GVS) on a weekly basis for 12 weeks (120 min total exposure). During each trial subjects performed computerized dynamic posturography and eye movements were measured using digital video-oculography. Follow up tests were conducted 6 weeks and 6 months after the 12-week adaptation period. Postural performance was significantly impaired during GVS at first exposure, but recovered to baseline over a period of 7-8 weeks (70-80 min GVS exposure). This postural recovery was maintained 6 months after adaptation. In contrast, the roll vestibulo-ocular reflex response to GVS was not attenuated by repeated exposure. This suggests that GVS adaptation did not occur at the vestibular end-organs or involve changes in low-level (brainstem-mediated) vestibulo-ocular or vestibulo-spinal reflexes. Faced with unreliable vestibular input, the cerebellum reweighted sensory input to emphasize veridical extra-vestibular information, such as somatosensation, vision and visceral stretch receptors, to regain postural function. After a period of recovery subjects exhibited dual adaption and the ability to rapidly switch between the perturbed (GVS) and natural vestibular state for up to 6 months. Copyright: © 2014 Dilda et al.Associated Grant:This study was funded by grants from the National Space Biomedical Research Institute (SA01603) and the National Aeronautics and Space Administration (NNX12AM25G

    Temporal characteristics of high-frequency lower-limb oscillation during freezing of gait in Parkinson's disease

    No full text
    Moore, ST ORCiD: 0000-0003-3995-4912A cardinal feature of freezing of gait (FOG) is high frequency (3-8 Hz) oscillation of the legs, and this study aimed to quantify the temporal pattern of lower-body motion prior to and during FOG. Acceleration data was obtained from sensors attached to the back, thighs, shanks, and feet in 14 Parkinson's disease patients performing timed-up-and-go tasks, and clinical assessment of FOG was performed by two experienced raters from video. A total of 23 isolated FOG events, defined as occurring at least 5 s after gait initiation and with no preceding FOG, were identified from the clinical ratings. The corresponding accelerometer records were analyzed within a 4 s window centered at the clinical onset of freezing. FOG-related high-frequency oscillation (an increase in power in the 3-8 Hz band >3 SD from baseline) followed a distal to proximal onset pattern, appearing at the feet, shanks, thighs, and then back over a period of 250 ms. Peak power tended to decrease as the focus of oscillation moved from feet to back. There was a consistent delay (mean 872 ms) between the onset of high frequency oscillation at the feet and clinical onset of FOG. We infer that FOG is characterized by high frequency oscillation at the feet, which progresses proximally and is mechanically damped at the torso. © 2014 Don A. Yungher et al.Associated Grant:Dr. Moore is supported by grants from the Michael J Fox Foundation, the National Space Biomedical Research Institute, and NASA flight study NNX09AL14G; Dr. Naismith is supported by an NHMRC Career Development Award no. 1008117; Dr. Lewis is supported by an NHMRC Practitioner Fellowship and a University of Sydney Rolf Edgar Lake Postdoctoral Fellowshi

    Pre-adaptation to noisy galvanic vestibular stimulation is associated with enhanced sensorimotor performance in novel vestibular environments

    No full text
    © 2015 Moore, Dilda, Morris, Yungher and MacDougall.Performance on a visuomotor task in the presence of novel vestibular stimulation was assessed in nine healthy subjects. Four subjects had previously been adapted to 120 min exposure to noisy Galvanic vestibular stimulation (GVS) over 12 weekly sessions of 10 min; the remaining five subjects had never experienced GVS. Subjects were seated in a flight simulator and asked to null the roll motion of a visual bar presented on a screen using a joystick. Both the visual bar and the simulator cabin were moving in roll with a pseudorandom (sum of sines) waveform that were uncorrelated. The cross correlation coefficient, which ranges from 1 (identical waveforms) to 0 (unrelated waveforms), was calculated for the ideal (perfect nulling of bar motion) and actual joystick input waveform for each subject. The cross correlation coefficient for the GVS-adapted group (0.90 [SD 0.04]) was significantly higher (t[8] = 3.162; p = 0.013) than the control group (0.82 [SD 0.04]), suggesting that prior adaptation to GVS was associated with an enhanced ability to perform the visuomotor task in the presence of novel vestibular noise

    Autonomous identification of freezing of gait in Parkinson's disease from lower-body segmental accelerometry

    Get PDF
    Moore, ST ORCiD: 0000-0003-3995-4912Background: We have previously published a technique for objective assessment of freezing of gait (FOG) in Parkinson's disease (PD) from a single shank-mounted accelerometer. Here we extend this approach to evaluate the optimal configuration of sensor placement and signal processing parameters using seven sensors attached to the lumbar back, thighs, shanks and feet. Methods. Multi-segmental acceleration data was obtained from 25 PD patients performing 134 timed up and go tasks, and clinical assessment of FOG was performed by two experienced raters from video. Four metrics were used to compare objective and clinical measures; the intraclass correlation coefficient (ICC) for number of FOG episodes and the percent time frozen per trial; and the sensitivity and specificity of FOG detection. Results: The seven-sensor configuration was the most robust, scoring highly on all measures of performance (ICC number of FOG 0.75; ICC percent time frozen 0.80; sensitivity 84.3%; specificity 78.4%). A simpler single-shank sensor approach provided similar ICC values and exhibited a high sensitivity to FOG events, but specificity was lower at 66.7%. Recordings from the lumbar sensor offered only moderate agreement with the clinical raters in terms of absolute number and duration of FOG events (likely due to musculoskeletal attenuation of lower-limb 'trembling' during FOG), but demonstrated a high sensitivity (86.2%) and specificity (82.4%) when considered as a binary test for the presence/absence of FOG within a single trial. Conclusions: The seven-sensor approach was the most accurate method for quantifying FOG, and is best suited to demanding research applications. A single shank sensor provided measures comparable to the seven-sensor approach but is relatively straightforward in execution, facilitating clinical use. A single lumbar sensor may provide a simple means of objective FOG detection given the ubiquitous nature of accelerometers in mobile telephones and other belt-worn devices. © 2013 Moore et al; licensee BioMed Central Ltd.Associated Grant:Dr. Moore is supported by NASA grants NNX09AL14G and NNX12AM25G and the National Space Biomedical Research Institute; Dr. MacDougall is supported by a grant from the Garnett Passe and Rodney Williams Memorial Foundation; Dr. Naismith is supported by an NHMRC Career Development Award No. 1008117; Dr. Lewis is supported by an NHMRC Practitioner Fellowship and a University of Sydney Rolf Edgar Lake Postdoctoral Fellowshi

    Central adaptation to repeated galvanic vestibular stimulation: Implications for pre-flight astronaut training

    No full text
    Healthy subjects (N=10) were exposed to 10-min cumulative pseudorandom bilateral bipolar Galvanic vestibular stimulation (GVS) on a weekly basis for 12 weeks (120 min total exposure). During each trial subjects performed computerized dynamic posturography and eye movements were measured using digital video-oculography. Follow up tests were conducted 6 weeks and 6 months after the 12-week adaptation period. Postural performance was significantly impaired during GVS at first exposure, but recovered to baseline over a period of 7-8 weeks (70-80 min GVS exposure). This postural recovery was maintained 6 months after adaptation. In contrast, the roll vestibulo-ocular reflex response to GVS was not attenuated by repeated exposure. This suggests that GVS adaptation did not occur at the vestibular end-organs or involve changes in low-level (brainstem-mediated) vestibulo-ocular or vestibulo-spinal reflexes. Faced with unreliable vestibular input, the cerebellum reweighted sensory input to emphasize veridical extra-vestibular information, such as somatosensation, vision and visceral stretch receptors, to regain postural function. After a period of recovery subjects exhibited dual adaption and the ability to rapidly switch between the perturbed (GVS) and natural vestibular state for up to 6 months. Copyright: © 2014 Dilda et al

    Pre-adaptation to noisy galvanic vestibular stimulation is associated with enhanced sensorimotor performance in novel vestibular environments

    Get PDF
    © 2015 Moore, Dilda, Morris, Yungher and MacDougall.Performance on a visuomotor task in the presence of novel vestibular stimulation was assessed in nine healthy subjects. Four subjects had previously been adapted to 120 min exposure to noisy Galvanic vestibular stimulation (GVS) over 12 weekly sessions of 10 min; the remaining five subjects had never experienced GVS. Subjects were seated in a flight simulator and asked to null the roll motion of a visual bar presented on a screen using a joystick. Both the visual bar and the simulator cabin were moving in roll with a pseudorandom (sum of sines) waveform that were uncorrelated. The cross correlation coefficient, which ranges from 1 (identical waveforms) to 0 (unrelated waveforms), was calculated for the ideal (perfect nulling of bar motion) and actual joystick input waveform for each subject. The cross correlation coefficient for the GVS-adapted group (0.90 [SD 0.04]) was significantly higher (t[8] = 3.162; p = 0.013) than the control group (0.82 [SD 0.04]), suggesting that prior adaptation to GVS was associated with an enhanced ability to perform the visuomotor task in the presence of novel vestibular noise

    Long-duration spaceflight adversely affects post-landing operator proficiency

    No full text
    Performance of astronaut pilots during space shuttle landing was degraded after a few weeks of microgravity exposure, and longer-term exposure has the potential to impact operator proficiency during critical landing and post-landing operations for exploration-class missions. Full-motion simulations of operationally-relevant tasks were utilized to assess the impact of long-duration spaceflight on operator proficiency in a group of 8 astronauts assigned to the International Space Station, as well as a battery of cognitive/sensorimotor tests to determine the underlying cause of any post-flight performance decrements. A ground control group (N = 12) and a sleep restriction cohort (N = 9) were also tested to control for non-spaceflight factors such as lack of practice between pre- and post-flight testing and fatigue. On the day of return after 6 months aboard the space station, astronauts exhibited significant deficits in manual dexterity, dual-tasking and motion perception, and a striking degradation in the ability to operate a vehicle. These deficits were not primarily due to fatigue; performance on the same tasks was unaffected after a 30-h period of sleep restriction. Astronauts experienced a general post-flight malaise in motor function and motion perception, and a lack of cognitive reserve apparent only when faced with dual tasks, which had recovered to baseline by four days after landing. © 2019, The Author(s)
    corecore