16 research outputs found

    Psychophysical Investigations into the Role of Low-Threshold C Fibres in Non-Painful Affective Processing and Pain Modulation

    Get PDF
    We recently showed that C low-threshold mechanoreceptors (CLTMRs) contribute to touch-evoked pain (allodynia) during experimental muscle pain. Conversely, in absence of ongoing pain, the activation of CLTMRs has been shown to correlate with a diffuse sensation of pleasant touch. In this study, we evaluated (1) the primary afferent fibre types contributing to positive (pleasant) and negative (unpleasant) affective touch and (2) the effects of tactile stimuli on tonic muscle pain by varying affective attributes and frequency parameters. Psychophysical observations were made in 10 healthy participants. Two types of test stimuli were applied: stroking stimulus using velvet or sandpaper at speeds of 0.1, 1.0 and 10.0 cm/s; focal vibrotactile stimulus at low (20 Hz) or high (200 Hz) frequency. These stimuli were applied in the normal condition (i.e. no experimental pain) and following the induction of muscle pain by infusing hypertonic saline (5%) into the tibialis anterior muscle. These observations were repeated following the conduction block of myelinated fibres by compression of sciatic nerve. In absence of muscle pain, all participants reliably linked velvet-stroking to pleasantness and sandpaper-stroking to unpleasantness (no pain). Likewise, low-frequency vibration was linked to pleasantness and high-frequency vibration to unpleasantness. During muscle pain, the application of previously pleasant stimuli resulted in overall pain relief, whereas the application of previously unpleasant stimuli resulted in overall pain intensification. These effects were significant, reproducible and persisted following the blockade of myelinated fibres. Taken together, these findings suggest the role of low-threshold C fibres in affective and pain processing. Furthermore, these observations suggest that temporal coding need not be limited to discriminative aspects of tactile processing, but may contribute to affective attributes, which in turn predispose individual responses towards excitatory or inhibitory modulation of pain

    Effect of frequency difference on sensitivity of beats perception

    Get PDF
    Two vibrations with slightly different frequencies induce the beats phenomenon. In tactile perception, when two pins of different frequencies stimulate the fingertips, an individual perceives a beats caused by a summation stimulus of the two vibrations. The present study demonstrates experimentally that humans can perceive another vibration based on the beats phenomenon when two tactile stimuli with slightly different frequencies are stimulated on the finger pad with a small contactor in different locations at the same time. Moreover, we examined the amplitude of the detection threshold to be able to perceive beats phenomenon on the index finger with 5 carrier frequency (63.1, 100, 158.5, 251.2, and 398.1 Hz) and 4 beats frequency (2.5, 3.98, 6.31, and 10 Hz) when two stimuli 1 mm distance apart are vibrated at a slightly different frequency. From the experiments, it is concluded that the amplitude threshold to be able to perceive beats decreases as the standard frequency increases under 398 Hz. Furthermore, from comparing the absolute detection threshold and beats detection threshold, as the carrier frequency increases, the required amplitude at two pins for the detection of beats decreases compared to absolute vibration

    Audiotactile interactions in temporal perception

    Full text link

    The effects of preferential A- and C-fibre blocks and T-type calcium channel antagonist on detection of low-force monofilaments in healthy human participants

    Full text link
    Background: A myriad of studies have argued that tactile sensibility is underpinned exclusively by large myelinated mechanoreceptors. However, the functional significance of their slow-conducting counterparts, termed C-low threshold mechanoreceptors (C-LTMRs), remains largely unexplored. We recently showed the emergence of brush- and vibration-evoked allodynia in human hairy and glabrous skin during background muscle pain. The allodynia persisted following the preferential blockade of myelinated fibres but was abolished by the preferential blockade of cutaneous C fibres, thereby suggesting a pathway involving hairy skin C-LTMRs and their functional counterparts in glabrous skin in this phenomenon. In the present study, we tested the effects of preferential A- and C-fibre conduction blocks and pharmacological blockade of T-type calcium channel Cav3.2 (expressed selectively on small-fibre LTMRs) on monofilament detection thresholds in healthy participants by compression, low-dose intradermal anaesthesia (xylocaine 0.25 %) and selective T-channel antagonist, TTA-A2. Results: We found that all participants could detect monofilament contacts (as low as 1.6 mN) within the innocuous tactile range regardless of the preferential blockade of myelinated fibres. Furthermore, during the compression block no subject reported a switch in modality from touch to pain. That is, the low-force monofilament contacts were always perceived as non-painful. However, there was a small but significant elevation of monofilament thresholds (~2 mN) in the glabrous skin following the compression block. Importantly, no differences were found in the thresholds across hairy and glabrous regions while the myelinated fibres were conducting or not. The preferential blockade of C fibres in the glabrous skin (with myelinated fibres intact) also resulted in a small but significant elevation of tactile thresholds. Furthermore, the use of T-channel blocker in the glabrous skin during compression block of myelinated fibres resulted in complete abolition of monofilament sensibility within the innocuous tactile range (tested up to ~20 mN). Conclusions: These observations suggest that C-LTMRs need not be regarded as a redundant tactile system, but appear to complement normal large-myelinated-fibre tactile function. Convergent findings in glabrous and hairy skin lend support for an underlying system of innocuous mechanoreception with Cav3.2-expressing unmyelinated fibres

    Electro-Tactile Stimulation Enhances Cochlear Implant Speech Recognition in Noise

    No full text
    For cochlear implant users, combined electro-acoustic stimulation (EAS) significantly improves the performance. However, there are many more users who do not have any functional residual acoustic hearing at low frequencies. Because tactile sensation also operates in the same low frequencies (<500 Hz) as the acoustic hearing in EAS, we propose electro-tactile stimulation (ETS) to improve cochlear implant performance. In ten cochlear implant users, a tactile aid was applied to the index finger that converted voice fundamental frequency into tactile vibrations. Speech recognition in noise was compared for cochlear implants alone and for the bimodal ETS condition. On average, ETS improved speech reception thresholds by 2.2 dB over cochlear implants alone. Nine of the ten subjects showed a positive ETS effect ranging from 0.3 to 7.0 dB, which was similar to the amount of the previously-reported EAS benefit. The comparable results indicate similar neural mechanisms that underlie both the ETS and EAS effects. The positive results suggest that the complementary auditory and tactile modes also be used to enhance performance for normal hearing listeners and automatic speech recognition for machines
    corecore