23 research outputs found
OptiJ: Open-source optical projection tomography of large organ samples
The three-dimensional imaging of mesoscopic samples with Optical Projection Tomography (OPT) has become a powerful tool for biomedical phenotyping studies. OPT uses visible light to visualize the 3D morphology of large transparent samples. To enable a wider application of OPT, we present OptiJ, a low-cost, fully open-source OPT system capable of imaging large transparent specimens up to 13 mm tall and 8 mm deep with 50 µm resolution. OptiJ is based on off-the-shelf, easy-to-assemble optical components and an ImageJ plugin library for OPT data reconstruction. The software includes novel correction routines for uneven illumination and sample jitter in addition to CPU/GPU accelerated reconstruction for large datasets. We demonstrate the use of OptiJ to image and reconstruct cleared lung lobes from adult mice. We provide a detailed set of instructions to set up and use the OptiJ framework. Our hardware and software design are modular and easy to implement, allowing for further open microscopy developments for imaging large organ samples
C-terminal calcium binding of α-synuclein modulates synaptic vesicle interaction.
Alpha-synuclein is known to bind to small unilamellar vesicles (SUVs) via its N terminus, which forms an amphipathic alpha-helix upon membrane interaction. Here we show that calcium binds to the C terminus of alpha-synuclein, therewith increasing its lipid-binding capacity. Using CEST-NMR, we reveal that alpha-synuclein interacts with isolated synaptic vesicles with two regions, the N terminus, already known from studies on SUVs, and additionally via its C terminus, which is regulated by the binding of calcium. Indeed, dSTORM on synaptosomes shows that calcium mediates the localization of alpha-synuclein at the pre-synaptic terminal, and an imbalance in calcium or alpha-synuclein can cause synaptic vesicle clustering, as seen ex vivo and in vitro. This study provides a new view on the binding of alpha-synuclein to synaptic vesicles, which might also affect our understanding of synucleinopathies
Concepts for structured illumination microscopy with extended axial resolution through mirrored illumination
Wide-field fluorescence microscopy, while much faster than confocal microscopy,
suffers from a lack of optical sectioning and poor axial resolution. 3D structured illumination
microscopy (SIM) has been demonstrated to provide optical sectioning and to double the
resolution limit both laterally and axially, but even with this the axial resolution is still worse than
the lateral resolution of unmodified wide-field microscopy. Interferometric schemes using two
high numerical aperture objectives, such as 4Pi confocal and I5M microscopy, have improved
the axial resolution beyond that of the lateral, but at the cost of a significantly more complex
optical setup. Here, we theoretically and numerically investigate a simpler dual-objective scheme
which we propose can be easily added to an existing 3D-SIM microscope, providing lateral and
axial resolutions in excess of 125 nm with conventional fluorophores and without the need for
interferometric detection
Concepts for structured illumination microscopy with extended axial resolution through mirrored illumination.
Wide-field fluorescence microscopy, while much faster than confocal microscopy, suffers from a lack of optical sectioning and poor axial resolution. 3D structured illumination microscopy (SIM) has been demonstrated to provide optical sectioning and to double the resolution limit both laterally and axially, but even with this the axial resolution is still worse than the lateral resolution of unmodified wide-field microscopy. Interferometric schemes using two high numerical aperture objectives, such as 4Pi confocal and I5M microscopy, have improved the axial resolution beyond that of the lateral, but at the cost of a significantly more complex optical setup. Here, we theoretically and numerically investigate a simpler dual-objective scheme which we propose can be easily added to an existing 3D-SIM microscope, providing lateral and axial resolutions in excess of 125 nm with conventional fluorophores and without the need for interferometric detection.CFK acknowledges funding from the UK EPSRC (EP/L015889/1, EP/H018301/1 and EP/G037221/1),
the Wellcome Trust (3-3249/Z/16/Z and 089703/Z/09/Z), the UK MRC (MR/K015850/1 and
MR/K02292X/1
Recommended from our members
C-terminal calcium binding of α-synuclein modulates synaptic vesicle interaction.
Alpha-synuclein is known to bind to small unilamellar vesicles (SUVs) via its N terminus, which forms an amphipathic alpha-helix upon membrane interaction. Here we show that calcium binds to the C terminus of alpha-synuclein, therewith increasing its lipid-binding capacity. Using CEST-NMR, we reveal that alpha-synuclein interacts with isolated synaptic vesicles with two regions, the N terminus, already known from studies on SUVs, and additionally via its C terminus, which is regulated by the binding of calcium. Indeed, dSTORM on synaptosomes shows that calcium mediates the localization of alpha-synuclein at the pre-synaptic terminal, and an imbalance in calcium or alpha-synuclein can cause synaptic vesicle clustering, as seen ex vivo and in vitro. This study provides a new view on the binding of alpha-synuclein to synaptic vesicles, which might also affect our understanding of synucleinopathies
OptiJ: Open-source optical projection tomography of large organ samples
The three-dimensional imaging of mesoscopic samples with Optical Projection Tomography (OPT) has become a powerful tool for biomedical phenotyping studies. OPT uses visible light to visualize the 3D morphology of large transparent samples. To enable a wider application of OPT, we present OptiJ, a low-cost, fully open-source OPT system capable of imaging large transparent specimens up to 13 mm tall and 8 mm deep with 50 µm resolution. OptiJ is based on off-the-shelf, easy-to-assemble optical components and an ImageJ plugin library for OPT data reconstruction. The software includes novel correction routines for uneven illumination and sample jitter in addition to CPU/GPU accelerated reconstruction for large datasets. We demonstrate the use of OptiJ to image and reconstruct cleared lung lobes from adult mice. We provide a detailed set of instructions to set up and use the OptiJ framework. Our hardware and software design are modular and easy to implement, allowing for further open microscopy developments for imaging large organ samples