12 research outputs found

    Beliefs and practices of patients with advanced cancer: implications for communication

    Get PDF
    The aim of this study was to investigate the beliefs that patients with advanced cancer held about the curability of their cancer, their use of alternatives to conventional medical treatment, and their need to have control over decisions about treatment. Of 149 patients who fulfilled the criteria for participation and completed a self-administered questionnaire, 45 patients (31%) believed their cancer was incurable, 61 (42%) were uncertain and 39 (27%) believed their cancer was curable. The index of need for control over treatment decisions was low in 53 patients (35.6%) and high in only 17 patients (11.4%). Committed users of alternatives to conventional medical treatments were more likely to believe that their cancer was curable (

    Dosimetric effects of a high-density spinal implant

    Get PDF
    In this study, a treatment plan for a spinal lesion, with all beams transmitted though a titanium vertebral reconstruction implant, was used to investigate the potential effect of a high-density implant on a three-dimensional dose distribution for a radiotherapy treatment. The BEAMnrc/DOSXYZnrc and MCDTK Monte Carlo codes were used to simulate the treatment using both a simplified, recltilinear model and a detailed model incorporating the full complexity of the patient anatomy and treatment plan. The resulting Monte Carlo dose distributions showed that the commercial treatment planning system failed to accurately predict both the depletion of dose downstream of the implant and the increase in scattered dose adjacent to the implant. Overall, the dosimetric effect of the implant was underestimated by the commercial treatment planning system and overestimated by the simplified Monte Carlo model. The value of performing detailed Monte Carlo calculations, using the full patient and treatment geometry, was demonstrated

    Development of a method for treating lower-eyelid carcinomas using superficial high dose rate brachytherapy

    No full text
    In this study, a method was developed for delivering high dose rate (HDR) brachytherapy treatments to basal cell carcinomas (BCCs) as well as squamous cell carcinomas (SCCs) of the lower eyelid via superficial catheters. Clinically-realistic BCC/SCC treatment areas were marked in the lower-eyelid region on a head phantom and several arrangements of catheters and bolus were trialled for treating those areas. The use of one or two catheters of different types was evaluated, and sources of dosimetric uncertainty (including air gaps) were evaluated and mitigated. Test treatments were planned for delivery with an iridium-192 source, using the Oncentra Brachy treatment planning system (Elekta AB, Stockholm, Sweden). Dose distributions were evaluated using radiochromic film. The proposed method was shown to be clinically viable, for using superficial HDR brachytherapy to overcome anatomical difficulties and create non-surgical treatments for BCC and SCC of the lower eyelid.</p

    Restoration of tolerance to rat hepatic allografts by spleen-derived passenger leukocytes

    No full text
    The tolerance induced by orthotopic liver transplantation (OLT) in certain combinations of rat strains can be prevented by total body irradiation (TBI) of the donor. We demonstrate here that the intravenous inoculation of splenic leukocytes into irradiated donors before OLT could re-establish tolerance in association with a state of microchimerism detected in the recipients. When donor DA (RT1(a)) strain rats were irradiated with 1000 rad 24 h before liver harvesting and subsequent liver implantation into PVG recipients, five out of six rats died from rejection in this normally tolerogenic OLT (DA-PVG) combination. Injection of 1.5 x 10(8) splenic leukocytes from naive DA rats into the irradiated DA donor rats 24 h before OLT restored the tolerogenic potential of the liver allografts. Immunofluorescence assay revealed an increased number of donor (DA) type cells in the PVG recipient bearing a repopulated DA liver, compared to the PVG recipient of an irradiated liver, These results suggest that passenger leukocytes reconstituted by splenic leukocytes have the capacity to protect liver allografts

    The prevention of graft-versus-host disease by the serum of liver retransplanted rats

    No full text
    The effect of serum from orthotopic liver retransplanted rats (re-OLT serum) on graft-versus-host disease (GVHD) was studied in rats. In the re-transplantation model of rat liver, orthotopic liver transplantation (OLT) was carried out in the DA (RT1) into PVG (RT1(c)) combination; two days later the DA liver was removed and a new PVG liver implanted into the same recipient (re-OLT). In the in vivo GVHD model, male PVG rats were sublethally irradiated and injected intravenously with 3 x 10 DA or BN (RT1(n)) spleen cells through the penial vein. Within 1 h of the inoculation, rats of the experimental group were injected with 1 ml of re-OLT serum taken at postoperative day (POD) 7. Rats in the control group received 1 ml of normal PVG serum or syngeneic re-OLT serum (PVG-PVG, PVG-PVG). All PVG rats in the control groups died of GVHD within 21 days after the inoculation of DA or BN spleen lymphocytes. However, when the animals were treated with re-OLT serum, 100% (6/6) of the rats survived more than 60 days, following inoculation with DA lymphocytes but not with BN lymphocytes. The POD 7 re-OLT serum showed a strong inhibition against DA anti-PVG mixed lymphocyte reaction (MLR), although re-OLT serum did not contain soluble DA class I antigens, anti-DA class I or II antibody. The potential GVHD inhibitory factors in re-OLT serum may be two unique immunosuppressive proteins, which have been detected by SDS PAGE and reported previously. We conclude that re-OLT serum has immunosuppressive factors, which, at least in part, prevented the induction of GVHD in rats

    Technical Note: Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution

    Get PDF
    Purpose: The component modules in the standard BEAMnrc distribution may appear to be insufficient to model micro-multileaf collimators that have tri-faceted leaf ends and complex leaf profiles. This note indicates, however, that accurate Monte Carlo simulations of radiotherapy beams defined by a complex collimation device can be completed using BEAMnrc's standard VARMLC component module.---------- Methods: That this simple collimator model can produce spatially and dosimetrically accurate micro-collimated fields is illustrated using comparisons with ion chamber and film measurements of the dose deposited by square and irregular fields incident on planar, homogeneous water phantoms.---------- Results: Monte Carlo dose calculations for on- and off-axis fields are shown to produce good agreement with experimental values, even upon close examination of the penumbrae.--------- Conclusions: The use of a VARMLC model of the micro-multileaf collimator, along with a commissioned model of the associated linear accelerator, is therefore recommended as an alternative to the development or use of in-house or third-party component modules for simulating stereotactic radiotherapy and radiosurgery treatments. Simulation parameters for the VARMLC model are provided which should allow other researchers to adapt and use this model to study clinical stereotactic radiotherapy treatments
    corecore